国产精品久久久久久久久,四季AV一区二区夜夜嗨,日韩精品无码中文字幕电影,www.五月婷婷.com

產(chǎn)品簡(jiǎn)介
美國(guó)Hausser細(xì)胞計(jì)數(shù)板
美國(guó)Hausser細(xì)胞計(jì)數(shù)板
產(chǎn)品價(jià)格:
上架日期:2022-10-31 15:27:56
產(chǎn)地:本地
發(fā)貨地:本地至全國(guó)
供應(yīng)數(shù)量:不限
最少起訂:1臺(tái)
瀏覽量:181
資料下載:暫無資料下載
其他下載:暫無相關(guān)下載
詳細(xì)說明

    美國(guó)Hausser細(xì)胞計(jì)數(shù)板

    美國(guó)Hausser細(xì)胞計(jì)數(shù)板(Nageotte Counting Chamber):亮線型,常用于單采血小板中的殘留白細(xì)胞的計(jì)數(shù)。池深:0.5mm。提供兩種:一種H型,中間有溝隔開為兩計(jì)數(shù)區(qū)(貨號(hào)4000),一種沒有溝槽(4001)美國(guó)Hausser scientific血球計(jì)數(shù)板,霍華德霉菌計(jì)數(shù)板,準(zhǔn)確計(jì)算白細(xì)胞、紅細(xì)胞、血小板、組織培養(yǎng)細(xì)胞、細(xì)菌和精子The Hausser Nageotte Bright-Line Hemacytometer allows one to manually count low leukocyte concentrations below the capabilities of a standard Hemacytometer. The Nageotte contains two gridded counting areas each containing 40 rectangular areas. Total volume of each grid is 50 mL for a total volume of 100 mL per Nageotte. The Nageotte can accuray measure down to 0.1 cell/mL (100 cell/ml). Cell Depth is 0.5mm .

    美國(guó)Hausser細(xì)胞計(jì)數(shù)板

    Available with an H-shaped moat(catalog#4000) that separates the two gridded areas or without a moat (catalog#4001). The Nageotte Chamber comes with two reusable cover slips(30mm X 33mm X 0.5mm) and 1/2 oz (approx. 35 pcs.) of disposable cover slips (30mm X 33mm X 0.15mm). PROCESS: Counting low levels of white cells in white cell-reduced plaetcomponents.BACKGROUND: Determination of the white cell (WBC) count in WBC-reduced plaet components requires bs that have a detection limit in the range of approximay 5.0 x 10(2) to 5.0 x 10(4) per mL.STUDY DESIGN AND METHODS: With a 50-microL Nageotte hemocytometer and bright-field microscopy (200x magnification), studies were conducted to develop and validate a b that could be used routinely with filtered and apheresis-harvested plaets. A 1-in-5 dilution of sample with a commercially available blood-diluting fluid was used because, with a lower (1-in-2) dilution, the observed number of WBCs was substantially less than the number expected at relatively high plaet counts (> 1.9 x 10(9)/mL). RESULTS: The observed and expected WBC counts in WBC-reduced plaet samples correlated well at levels between approximay 5 and 1100 WBCs per counting area (5.0 x 10(2)-1.1 x 10(5)/mL). At levels of more than 300 to 400 WBCs per counting area, accurate counts were obtained when 10 of the 40 rectangles were counted.


    http://www.shheyukj.com/Products-28067542.html
    http://www.chem17.com/st357451/erlist_2167798.html

在線詢盤/留言
  • 免責(zé)聲明:以上所展示的信息由企業(yè)自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布企業(yè)負(fù)責(zé),本網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。我們?cè)瓌t 上建議您選擇本網(wǎng)高級(jí)會(huì)員或VIP會(huì)員。
    企業(yè)信息
    江蘇明珠試驗(yàn)機(jī)械有限公司
    會(huì)員級(jí)別:
    ------------ 聯(lián)系方式 ------------
    聯(lián)系人:李先生(先生)
    聯(lián)系電話:0514-86235391
    聯(lián)系手機(jī):18268080050
    傳真號(hào)碼:0514-86235391
    企業(yè)郵箱:18268080050@163.com
    網(wǎng)址:dalnim.jdzj.com
    郵編:225264
    推薦供應(yīng)
    0571-87774297