60W Triple Output Series - with approval
Universal AC b / full range
High reliability
Approvals: ETS/LVD/EMC/ CE
100% full load burn-in test
Protections: overload/ over voltage/ short circuit
V1 is isolated from the other outputs
2 years warranty
F605 160 x 98 x 39(mm)
AC b voltage range ................... 85~264VAC (120~370VDC)
Inrush current .................................. cold start, 20A/115V, 40A/230V
Input leakage current ...................... 0.7mA/ 230VAC
Line regulation (full load) ................. 0.5%
Load regulation ................................ V1: 0.5%, V2,V3: 3% (with regulators);
6% (without)
Output voltage adjust range ........... V1: 5% of rated output voltage
Output overload protection ............. 110~150%
Output over voltage protection ....... 115~150%
Withstand voltage ........................... I/P-O/P: 3.0KVAC/1min;I/P-F/G: 1.5KVAC/1min
O/P-F/G: 0.5KVAC/1min
Rise, Hold up time ......................... 50ms, 20ms@full load (typical)
Operating temp. & humidity ............ -10 ~+50 , 20%~93%RH (non condensing)
Storage temp. & humidity ............... -20 ~+85 , 20%~95%RH (non condensing)
Safety standards ............................ GB4943, UL60950, EN60950
EMC standards ............................... GB9254, EN55022 classB, EN55024
EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
Cooling b ............................... convection
Model DC Output R&N Efficiency
5V 0.5~6.0A 80mV
HF60W-TL-A 12V 0.0~2.0A 100mV 71%
-12V 0.2~1.5A 100mV
5V 0.6~7.0A 80mV
HF60W-TL-B 15V 0.0~2.0A 100mV 72%
-15V 0.0~1.0A 100mV
5V 0.7~8.0A 80mV
HF60W-TL-C 12V 0.0~2.0A 100mV 70%
-5V 0.0~1.5A 80mV
Drawing