国产精品久久久久久久久,四季AV一区二区夜夜嗨,日韩精品无码中文字幕电影,www.五月婷婷.com

產(chǎn)品簡介
002HN放療測試體模
002HN放療測試體模
產(chǎn)品價(jià)格:¥100
上架日期:2018-08-27 09:51:44
產(chǎn)地:美國
發(fā)貨地:廣東深圳
供應(yīng)數(shù)量:不限
最少起訂:1臺
瀏覽量:206
資料下載:暫無資料下載
其他下載:暫無相關(guān)下載
詳細(xì)說明

    CIRS 002HN放療測試體模


    The CIRS Model 002HN IMRT phantom is designed to address the complex issues surrounding commissioning and comparison of treatment planning systems and verification of individual patient plans and delivery.


    The CIRS 002HN phantom properly represents human head and neck anatomy in shape, proportion and structure as well as density.  This enables thorough analysis of both the treatment planning and delivery systems. The phantom is constructed of proprietary tissue equivalent epoxy materials.  Linear attenuations of the simulated tissues are within 1% of actual attenuation for bone and water from 50 keV to 15 MeV。


    The phantom is circular in shape, approximates the size of an average patient.  Tissue equivalent interchangeable rod inserts for ionization chambers allow for point dose measurements in multiple planes in the phantom and film calibration.*  The phantom also supports film

     dosimetry with not only standard radiographic films but also GafChromic®media.  Additional inserts are available to support a variety of other detectors including TLD’s, MOSFET, and diodes.


    The Model 002HN accommodates one Ready PackTM 10” x 12” films in transverse orientation, two radiochromic or radiographic 10 x 10 cm films in transverse orientation and a stack of thirteen radiochromic films pre-cut to 63.5 x 63.5 mm in three different orientations. Email:hongqi@thingstest.com


    The Model 002HN has an optional four Electron Density reference plugs which can be interchanged in five separate bs within the phantom. The surface of the phantom is etched with grooves to ensure proper orientation of the CT slices and accurate film to plan registration. An optional cranial bone ring is also available.

    美國CIRS 002HN放療測試體模特點(diǎn):

    • Verify heterogeneity corrections Email:15920060912@139.com

    • Correlate CTU to electron density

    • Check dose distributions in sensitive areas Tel:86-755-22934005

    • Check depth doses and absolute dose Tel:0755-22913855

    • 2D and 3D isodoses Email:hongqi@thingstest.com

    • Calibrate film with ion chamber*

    • Verify individual patient treatment plans Tel:0755-22913855

    IMRT Verification System

    CIRS IMRT phantoms are manufactured from tissue equivalent materials that mimic within 1% from 50 keV to 15 MeV for accurate simulation from CT planning to treatment delivery.  The interchangeable rod design allows the phantom to accommodate a multitude of dose measurement devices such as ion chambers, TLD, diodes and MOSFET's in the same b within the phantom.  Phantom cross sections accommodate GafChromic® or standard ready-pack films.


    *NOTE: This product or an optional accessory of this product requires a CIRS dosimetry cavity code before an order can be placed. Please refer to the Dosimetry Cavity Codes document to identify the CIRS code for the probe you intend to use with this product.


    The CIRS line of IMRT phantoms is compatible with the RIT 113 software for film to plan analysis. GafChromic® is a registered trademark of International Specialty Products, Wayne, NJ.


在線詢盤/留言
  • 免責(zé)聲明:以上所展示的信息由企業(yè)自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布企業(yè)負(fù)責(zé),本網(wǎng)對此不承擔(dān)任何保證責(zé)任。我們原則 上建議您選擇本網(wǎng)高級會員或VIP會員。
    企業(yè)信息
    深圳市展業(yè)達(dá)鴻科技有限公司
    會員級別:
    ------------ 聯(lián)系方式 ------------
    聯(lián)系人:林國靖(先生)
    聯(lián)系電話:0755-22934005
    聯(lián)系手機(jī):15920060912
    傳真號碼:0755-22913855
    企業(yè)郵箱:13723768513@139.com
    網(wǎng)址:lingj08.jdzj.com
    郵編:51800
    推薦供應(yīng)
    0571-87774297