2、為便于用戶替代電磁型電壓繼電器,請按下表對照。
型 號 |
電壓整定 范圍(V) |
觸點與數(shù)量 |
輔助電源端子號 |
替代繼電器型號 |
備注 |
||
動合 |
動斷 |
正極 |
負極 |
||||
JY-11A |
0.5~99.5 |
1 |
1 |
4 |
6 |
DJ-111;DJ-121 DJ-131 |
過 電 壓 |
JY-11B |
40~439 |
4 |
6 |
||||
JY-21A |
0.5~99.5 |
6 |
7 |
DY-21C;DY-22C DY-23C;DY-21/60C |
|||
JY-21B |
40~439 |
6 |
7 |
||||
JY-31A |
0.5~99.5 |
4 |
6 |
DJ-31;DJ-32 DJ-32/60C |
|||
JY-31B |
40~439 |
4 |
6 |
||||
JY-12A |
0.5~99.5 |
6 |
6 |
DJ-112;DJ-122 DJ-132 |
低 電 壓 |
||
JY-12B |
40~439 |
6 |
6 |
||||
JY-22A |
0.5~99.5 |
4 |
7 |
DY-26C;DY-28C |
|||
JY-22B |
40~439 |
4 |
7 |
DY-23C;DY-21/60C |
|||
JY-32A |
0.5~99.5 |
6 |
6 |
DJ-35;DJ-36 |
|||
JY-32B |
40~439 |
6 |
6 |
||||
JY-123OA |
0.5~99.5 |
7 |
8 |
DJ-100 DY-21C DY-30 無殼 |
過電壓 |
||
JY-123OB |
40~439 |
7 |
8 |
||||
JY-123UA |
0.5~99.5 |
7 |
8 |
低電壓 |
|||
JY-123UB |
40~439 |
7 |
8 |
注:觸點數(shù)量也可提供二副動合或二副動斷觸點,但訂貨時必須說明,所以本繼電器也可替代DY-24C、DY-25C、DY-27C和DY-29C。
3、主要技術(shù)參數(shù)
3.1 額定值
直流額定值:24、48、110、220V
交流額定值:“A”類繼電器100V,50Hz
“B”類繼電器500V,50Hz
3.2 觸點形式
JY-20系列、20系列、30系列繼電器提供一動合、一動斷觸點,也可提供二副動合或二副動斷觸電,但訂貨時必須說明。
3.3 工作特性
a.動作電壓整定范圍:“A”0.5~99.5V “B”40~439V。
b.返回系數(shù)
過電壓繼電器返回系數(shù)不小于0.95;
低電壓繼電器返回系數(shù)不小于1.05。
c.準確度
c.1 平均誤差:在其條件下,整定值在1V至最值范圍內(nèi),平均誤差不大于3%。
c.2 一致性
在基準條件下,在同一整定點上,動作值5次測量的最大值與最小值之代數(shù)差應不大于整定值的5%。
3.4 動作時間
過電壓繼電器1.2倍整定值的動作時間不大于25ms。
2倍整定值的動作時間不大于20ms。
低電壓繼電器0.5倍整定值的動作時間不大于20ms。
3.5 返回時間不大于27ms。
3.6 觸點容量
在電壓不大于250V,電流不大于2A的直流有感負荷電壓(τ=5±0.75ms)中,繼電器觸點斷開容量為30W。或在電壓不大于250V,電流不大于0.5A的交流電路(cosΦ=0.4±0.1)中,繼電器觸點斷開容量為150VA。
繼電器觸點長期允許閉合電流為5A。