西門(mén)子DP總線電纜6XV1830-OEH10
西門(mén)子DP總線電纜6XV1830-OEH10
SIPLUS PS PSU3400 DC 24 V/10 A 導(dǎo)軌 基于 6EP3134-0TA00-0AY0 帶防腐蝕涂層, -40 - +70°C, OT4 帶 ST1/2 (+85°C 持續(xù) 10分鐘), 穩(wěn)定電源 輸入:24 V DC(14…32 V) 輸出:24 V DC/10 A
|
SIPLUS DC/DC converters – for a stable power supply, even with b voltage fluctuations
The advantages at a glance:
Article number |
6AG2134-0TA00-3AY0 |
|
---|---|---|
Product |
SIPLUS PSU3400 RAIL |
|
Power supply, type |
24 V/10 A |
|
Input |
|
|
type of the power supply network |
DC voltage |
|
supply voltage at AC |
|
|
|
Startup as of 18 V, derating necessary for 14 ... 18 V DC |
|
supply voltage |
|
|
|
24 ... 24 V |
|
b voltage |
|
|
|
14 ... 32 V |
|
design of b wide range b |
No |
|
overvoltage overload capability |
- |
|
operating condition of the mains buffering |
at Vin = 24 V |
|
buffering time for rated value of the output current in the event of power failure minimum |
5 ms |
|
operating condition of the mains buffering |
at Vin = 24 V |
|
b current |
|
|
|
10.8 A |
|
current limitation of inrush current at 25 °C maximum |
15 A |
|
I2t value maximum |
0.6 A2·s |
|
fuse protection type |
25 A (not accessible), breaking capacity 300 A |
|
|
Recommended miniature circuit breaker: 16 A characteristic B or C |
|
Output |
|
|
voltage curve at output |
Controlled, isolated DC voltage |
|
output voltage at DC rated value |
24 V |
|
relative overall tolerance of the voltage |
1 % |
|
relative control precision of the output voltage |
|
|
|
0.1 % |
|
|
0.3 % |
|
residual ripple |
|
|
|
150 mV |
|
|
30 mV |
|
voltage peak |
|
|
|
250 mV |
|
|
50 mV |
|
adjustable output voltage |
24 ... 28 V |
|
product function output voltage adjustable |
Yes |
|
type of output voltage setting |
via potentiometer |
|
display version for normal operation |
Green LED for 24 V OK |
|
type of signal at output |
Relay contact (NO contact, contact rating 30 V AC/0.5 A; 60 V DC/0.3 A; 30 V DC/1 A) for 24 V O.K. |
|
behavior of the output voltage when switching on |
No overshoot of Vout (soft start) |
|
response delay maximum |
0.5 s |
|
voltage increase time of the output voltage |
|
|
|
10 ms |
|
|
20 ms |
|
output current |
|
|
|
10 A |
|
|
0 ... 12.5 A; 12 A up to +40°C; +60 ... +70 °C: Derating 2%/K |
|
supplied active power typical |
260 W |
|
product feature |
|
|
|
can be set with DIP switch |
|
|
Yes; switchable characteristic |
|
number of parallel-switched equipment resources for increasing the power |
2 |
|
Efficiency |
|
|
efficiency in percent |
93 % |
|
power loss [W] |
|
|
|
20 W |
|
|
1.5 W |
|
Closed-loop control |
|
|
relative control precision of the output voltage with rapid fluctuation of the b voltage by +/- 15% typical |
0.3 % |
|
relative control precision of the output voltage load step of resistive load 50/100/50 % typical |
2 % |
|
setting time |
|
|
|
1 ms |
|
|
1 ms |
|
Protection and monitoring |
|
|
design of the overvoltage protection |
Ua < 35 V |
|
response value current limitation typical |
13 A |
|
property of the output short-circuit proof |
Yes |
|
design of short-circuit protection |
Electronic shutdown, automatic restart |
|
display version for overload and short circuit |
Yellow LED overload |
|
Safety |
|
|
galvanic isolation between b and output |
Yes |
|
galvanic isolation |
Safety extra low output voltage Vout according to EN 60950-1 |
|
operating resource protection class |
Class III |
|
protection class IP |
IP20 |
|
Approvals |
|
|
certificate of suitability |
|
|
|
Yes |
|
certificate of suitability |
|
|
|
Yes; EMC for rail vehicles |
|
|
Yes |
|
|
Yes; Rail vehicles - see ambient conditions |
|
|
Yes; Rail vehicles - Temperature class OT3, ST1/ST2, horizontal installation |
|
|
Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B |
|
|
Yes; Proof see Service & Support |
|
EMC |
|
|
standard |
|
|
|
EN 61000-6-3 |
|
|
not applicable |
|
|
EN 61000-6-2 |
|
environmental conditions |
|
|
ambient temperature |
|
|
|
-25 ... +70 °C |
|
|
-40 ... +85 °C |
|
|
-40 ... +85 °C |
|
|
-25 ... +70 °C; with natural convection |
|
|
-40 ... +85 °C |
|
installation altitude at height above sea level maximum |
6 000 m |
|
ambient condition relating to ambient temperature - air pressure - installation altitude |
In case of operation at altitudes of 2000 - 6000 m above sea level: Output power derating of -7.5 %/1000 m or reduction of the ambient temperature by 5 K/1000 m |
|
relative humidity with condensation according to IEC 60068-2-38 maximum |
100 %; RH incl. condensation/frost (no commissioning if condensation is present), horizontal installation |
|
chemical resistance to commercially available cooling lubricants |
Yes; incl. diesel and oil droplets in the air |
|
resistance to biologically active substances conbity according to EN 60721-3-3 |
Yes; Class 3B2 mold, fungal, sponge spores (except fauna); class 3B3 upon request |
|
resistance to chemically active substances conbity according to EN 60721-3-3 |
Yes; Class 3C4 (RH < 75%) incl. salt spray acc. to EN 60068-2-52 (severity level 3) |
|
resistance to mechanically active substances conbity according to EN 60721-3-3 |
Yes; Class 3S4 incl. sand, dust |
|
coating for equipped printed circuit board according to EN 61086 |
Yes; Class 2 for high availability |
|
type of coating protection against pollution according to EN 60664-3 |
Yes; Type 1 protection |
|
type of coating for electronic devices in railway applications according to EN 50155 |
Yes; Protective coating of Class PC2 acc. to EN 50155:2017 |
|
type of test of the coating according to MIL-I-46058C |
Yes; Discoloration of the coating during service life possible |
|
product conbity of the coating Qualification and Perbance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A |
Yes; Conbal Coating, Class A |
|
Mechanics |
|
|
type of electrical connection |
screw-type terminals |
|
|
L, N, FE: 1 screw terminal each for 0.5 ... 2.5 mm2 single-core/finely stranded |
|
|
+, -: 2 screw terminals each for 0.5 ... 2.5 mm2 |
|
|
Alarm signals: 2 screw terminals for 0.5 ... 2.5 mm2 |
|
|
2 screw terminals for 0.5 ... 2.5 mm2 |
|
b of the enclosure |
42 mm |
|
height of the enclosure |
125 mm |
|
depth of the enclosure |
120 mm |
|
required spacing |
|
|
|
50 mm |
|
|
50 mm |
|
|
0 mm |
|
|
0 mm |
|
net weight |
0.6 kg |
|
product feature of the enclosure housing can be lined up |
Yes |
|
fastening b |
Snaps onto DIN rail EN 60715 35x7.5/15 |
|
electrical accessories |
Buffer module |
|
MTBF at 40 °C |
1 579 080 h |
|
other inbation |
Specifications at rated b voltage and ambient temperature +25 °C (unless otherwise specified) |
西門(mén)子DP總線電纜6XV1830-OEH10 西門(mén)子DP總線電纜6XV1830-OEH10