NCU 573.5/573.4/573.3/573.2/572.5/572.4/572.3/572.2/571.5/561.5/571.4/571.3/571.2
NCU 572.2 6FC5357-0BB21-0AE0 現(xiàn)貨特價
NCU 572.2 6FC5357-0BB21-0AE1 現(xiàn)貨特價
NCU 572.2 6FC5357-0BB52-0AE0 現(xiàn)貨特價
===================
上海啟水自動化科技有限公司(西門子核心分銷商)
聯(lián)系人 :李 明 松( 銷售經(jīng)理 )24小時服務(wù)熱線 :186 0165 7819
電話( Tel ): 021-60641328
工作( Q Q ) :1471187088 郵箱( Email )::1471187088@qq.com
地址( Add ):上海市松江區(qū)弘翔路58號195
公司優(yōu)勢產(chǎn)品系列=西門子S7-200CN | S7-300PLC | 觸摸屏 | 變頻器 | 伺服電機 | 數(shù)控系統(tǒng) | 總線電纜| 開關(guān)電源
====================
We would like to inb you about a new component for the SINUMERIK 840D/DE control. The enhanced-perbance NCU 573.2 Order No. ÄMLFBÜ 6FC5357-0BB33-0AE1 is released for general availability and is now available. It cannot be used as spare part for previous NCUs 573/573.2. The new NCU 573.2 has a perbance which has been increased by to 40% regarding the computational perbance (the Inb Pentium Pro processor 200 MHz has been replaced by the Pentium II 266 MHz with 256 kB cache) and the user memory has been increased from 1.5 to 2.5 MB. NCU Order No.ÄMLFBÜ Acquisitional text ----------------------------------------------------------- 573.2 6FC5357-0BB33-0AE1 SINUMERIK 840D/DE NCU 573.2 PENTIUM II WITHOUT SYSTEM SOFTWARE MEMORY: NC 2.5MB, PLC 64KB PREPARED FOR PROFIBUS-DP - The system software on PC card must be ordered separaby specifying the software release! PRODOK Info No. 1998/060 is valid - NCU 573.2 can be upgraded, as before, using options: 6FC5252-0AA03-0AA0 PLC user memory expansion by 32 kB (this can be expanded up to 288 kB) 6FC5252-0AD00-0AA0 Peripheral interface via Profibus DP When ordered from LZE (new business) the previously supplied NCU 573.2, Order No.ÄMLFBÜ 6FC5357-0BB33-0AE0 will be substituted by the new NCU 573.2, Order No.ÄMLFBÜ 6FC5357-0BB33-0AE1 after the stock inventory has been reduced to zero (approx. middle of 6/99). The previous NCU 573.2 with Pentium Pro will remain available until further notice for spare parts supply. Compatibility: The new NCU 573.2 is compatible, as far as the hardware is concerned, to the previous NCU 573.2. The new NCU 573.2 however, requires the following software versions to offer full compatibility: SW-release Version Comments ------------------------------------------------------------------- 3.6 > V03.06.11 more detailed info will be provided 3.7 > V03.07.14 more detailed info will be provided 4.3 > V04.03.12/13/14 more detailed info will be provided completed on 28.07.99; Bader 4.4 V04.04.27 available from the end of 05/99 5.1 V05.01.2x available from the end of 05/99