品牌:西門子
西門子SINAMICS6SL3210-1KE22-6AP1
希殿電氣技術(shù)(上海)有限公司(西門子代理)
聯(lián) 系 :康(銷售工程師)
Q Q :192061030
手 機 :18621061383(微信
郵 箱 :192061030@qq.com
由于西門子產(chǎn)品型號實在太多,很多產(chǎn)品沒有及時上架,如需要西門子產(chǎn)品可以隨時聯(lián)系!
Single-encoder system
Example: Single-encoder system
In a single-encoder system, the motor encoder is used exclusively for safe actual value sensing.
Dual-encoder system
Example: Dual-encoder system
In the case of the 2-encoder system, the safe actual values for a drive are provided by two separate encoders. The actual values are transferred to the Control Unit over DRIVE-CLiQ. When motors without a DRIVE-CLiQ connection are used, a Sensor Module must be provided.
HTL/TTL incremental encoders can be used as an alternative with a dual-encoder system. Either two HTL/TTL encoders, one dual-HTL/TTL encoder or one HTL/TTL encoder and one sin/cos encoder can be used.
The safety functions are listed below with criteria for actual value sensing
Functions |
Abbreviation |
With encoder |
Without encoder |
Debion |
|
---|---|---|---|---|---|
Basic Functions |
Safe Torque Off |
STO |
Yes |
Yes |
Safe Torque Off |
Safe Stop 1 |
SS1 |
Yes |
Yes |
Safe stopping process in accordance with stop category 1 |
|
Safe Brake Control |
SBC |
Yes |
Yes |
Safe Brake Control |
|
Extended Functions |
Safe Torque Off |
STO |
Yes |
Yes |
Safe Torque Off |
Safe Stop 1 |
SS1 |
Yes |
Yes 1) |
Safe stopping process in accordance with stop category 1 |
|
Safe Brake Control |
SBC |
Yes |
Yes |
Safe Brake Control |
|
Safe Operating Stop |
SOS |
Yes |
No |
Safe monitoring of the standstill b |
|
Safe Stop 2 |
SS2 |
Yes |
No |
Safe stopping process in accordance with stop category 2 |
|
Safely Limited Speed |
SLS |
Yes |
Yes 1) |
Safe monitoring of the maximum speed |
|
Safe Speed Monitor |
SSM |
Yes |
Yes 1) |
Safe monitoring of the minimum speed |
|
Safe Direction |
SDI |
Yes |
Yes 1) |
Safe monitoring of the direction of motion |
|
Safely Limited Position |
SLP |
Yes |
No |
Safely-limited b |
|
Safe Position |
SP |
Yes |
Yes 2) |
Safe transfer of b values |
|
Safe Brake Test |
SBT |
Yes |
No |
Diagnostic function for safe testing of the required holding torque of a brake |
1) The use of this safety function without encoder is permitted for induction motors or synchronous motors of the SIEMOSYN series.
2) Only for the transmission of relative b values. An encoder is required to transmit absolute b values.