General inbation
|
|
|
Engineering with
|
|
|
|
STEP 7 V5.5 or higher, Distributed Safety V5.4 SP4
|
STEP 7 V5.5 or higher, Distributed Safety V5.4 SP4
|
Supply voltage
|
|
|
Rated value (DC)
|
|
|
|
Yes
|
Yes
|
Power loss
|
|
|
Power loss, typ.
|
4.65 W
|
4.65 W
|
Memory
|
|
|
Work memory
|
|
|
|
1 536 kbyte
|
1 536 kbyte
|
|
256 kbyte
|
256 kbyte
|
Load memory
|
|
|
|
8 Mbyte
|
8 Mbyte
|
CPU processing times
|
|
|
for bit operations, typ.
|
0.025 µs
|
0.025 µs
|
for word operations, typ.
|
0.03 µs
|
0.03 µs
|
for fixed point arithmetic, typ.
|
0.04 µs
|
0.04 µs
|
for floating point arithmetic, typ.
|
0.16 µs
|
0.16 µs
|
Counters, timers and their retentivity
|
|
|
S7 counter
|
|
|
|
512
|
512
|
IEC counter
|
|
|
|
Yes
|
Yes
|
S7 times
|
|
|
|
512
|
512
|
IEC timer
|
|
|
|
Yes
|
Yes
|
Data areas and their retentivity
|
|
|
Flag
|
|
|
|
4 096 byte
|
4 096 byte
|
Address area
|
|
|
I/O address area
|
|
|
|
8 192 byte
|
8 192 byte
|
|
8 192 byte
|
8 192 byte
|
Process image
|
|
|
|
8 192 byte
|
8 192 byte
|
|
8 192 byte
|
8 192 byte
|
Operating hours counter
|
|
|
|
4
|
4
|
1. Interface
|
|
|
Interface type
|
Integrated RS 485 interface
|
Integrated RS 485 interface
|
Physics
|
RS 485
|
RS 485
|
Functionality
|
|
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
No
|
No
|
DP master
|
|
|
|
124
|
124
|
2. Interface
|
|
|
Interface type
|
PROFINET
|
PROFINET
|
Physics
|
Ethernet RJ45
|
Ethernet RJ45
|
Interface types
|
|
|
|
2
|
2
|
Functionality
|
|
|
|
No
|
No
|
|
Yes; Also simultaneously with IO-Device functionality
|
Yes; Also simultaneously with IO-Device functionality
|
|
Yes; Also simultaneously with IO Controller functionality
|
Yes; Also simultaneously with IO Controller functionality
|
|
Yes
|
Yes
|
|
No
|
No
|
|
No
|
No
|
Isochronous mode
|
|
|
Isochronous operation (application synchronized up to terminal)
|
Yes; Via PROFIBUS DP or PROFINET interface
|
Yes; Via PROFIBUS DP or PROFINET interface
|
Communication functions
|
|
|
PG/OP communication
|
Yes
|
Yes
|
Data record routing
|
Yes
|
Yes
|
Global data communication
|
|
|
|
Yes
|
Yes
|
S7 basic communication
|
|
|
|
Yes
|
Yes
|
S7 communication
|
|
|
|
Yes
|
Yes
|
S5 compatible communication
|
|
|
|
Yes; via CP and loadable FC
|
Yes; via CP and loadable FC
|
Open IE communication
|
|
|
|
Yes; via integrated PROFINET interface and loadable FBs
|
Yes; via integrated PROFINET interface and loadable FBs
|
|
16
|
16
|
|
Yes; via integrated PROFINET interface and loadable FBs
|
Yes; via integrated PROFINET interface and loadable FBs
|
|
16
|
16
|
|
Yes; via integrated PROFINET interface and loadable FBs
|
Yes; via integrated PROFINET interface and loadable FBs
|
|
16
|
16
|
Web server
|
|
|
|
Yes
|
Yes
|
Number of connections
|
|
|
|
32
|
32
|
Ambient conditions
|
|
|
Ambient temperature during operation
|
|
|
|
-25 °C; = Tmin
|
-25 °C; = Tmin
|
|
60 °C; = Tmax
|
60 °C; = Tmax; the rated temperature range of -25 ... +55 °C (T1) applies for the use on railway vehicles according to EN50155
|
Ambient temperature during storage/transportation
|
|
|
|
-40 °C
|
-40 °C
|
|
70 °C
|
70 °C
|
Extended ambient conditions
|
|
|
|
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)
|
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m)
|
Relative humidity
|
|
|
|
100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
|
100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
|
Resistance
|
|
|
|
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation in corrosive atmospheres!
|
|
Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation!
|
|
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
|
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation!
|
Configuration
|
|
|
Programming
|
|
|
Programming language
|
|
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
|
Yes
|
Yes
|
Know-how protection
|
|
|
|
Yes
|
Yes
|
|
Yes; With S7 block Privacy
|
Yes; With S7 block Privacy
|
Dimensions
|
|
|
Width
|
40 mm
|
40 mm
|
Height
|
125 mm
|
125 mm
|
Depth
|
130 mm
|
130 mm
|
Weights
|
|
|
Weight, approx.
|
340 g
|
340 g
|