6GK5491-2AB00-8AA2
6GK5491-2AB00-8AA2
產(chǎn)品價格:¥1
上架日期:2016-08-19 10:46:01
產(chǎn)地:德國
發(fā)貨地:電話
供應(yīng)數(shù)量:不限
最少起訂:1臺
瀏覽量:26
資料下載:暫無資料下載
其他下載:暫無相關(guān)下載
詳細(xì)說明

    上海渤倫機電設(shè)備有限公司

    具備如下業(yè)務(wù)優(yōu)勢: 

    SIEMENS  
    可編程控制器 
    1、  SIMATIC  S7  系列PLC、S7-200、S7-200Smart、s7-1200、S7-300、S7-400ET200 
    2、  邏輯控制模塊  LOGO!230RC、230RCO230RCL、24RC、24RCL 
    3  SITOP  系列直流電源  24V  DC  1.3A、2.5A、3A、5A10A、20A40A 
        4
    、HMI  觸摸屏TD200  TD400C  TP177,MP277  MP377  SMART700  SMART1000 
      SIEMENS  
    交、直流傳動裝置 
    1、交流變頻器  MICROMASTER系列:MM、MM420、MM430、MM440、ECO 
    MIDASTER系列:MDV 
    6SE70系列(FC、VC、SC 
    2、全數(shù)字直流調(diào)速裝置  6RA23、6RA246RA28、6RA70  系列 
    SIEMENS  
    數(shù)控  伺服 
    1
    、數(shù)控系統(tǒng):840D、802S/C、802SL、828D  801D  6FC5210,6FC6247,6FC5357,6FC5211,6FC5200,6FC5510,
              2
    、伺服系統(tǒng):  611U:  6SN1123,6SN1145,6SN1146,6SN1118,6SN1110,6SN1124,6SN1125,6SN1128、
              3
    、伺服系統(tǒng):S120:  6SL3046SL3210、6SL31306SL3055、6SL30

    ^ǒ^**^ǒ^**^ǒ^**^ǒ^**^ǒ^*^ǒ^**^ǒ^**^ǒ^**^ǒ^*^ǒ 

    ┃╭╮┏┯┓┏┯┓ ┏┯┓┏┯┓┏┯┓┏┯┓ ┏┯┓┏┯┓┏┯┓ ╮┃

     ╲╱ ┨┠ ┨┠┨┠西┨┠ ┨┠┨┠  ╲╱  

    ┃┗┛┗┷┛┗┷┛ ┗┷┛┗┷┛┗┷┛┗┷┛ ┗┷┛┗┷┛┗┷┛ ┛┃

    ^ǒ^**^ǒ^**^ǒ^**^ǒ^**^ǒ^*^ǒ^**^ǒ^**^ǒ^**^ǒ^*^ǒ

      聯(lián)       :方祖付 (銷售經(jīng)理)

      24 小時 手機 18721545542

      電話(T e l):+86-021-60441303

      傳真(F a x):+86-021-57980279

      商務(wù)( Q Q ):2798596102

     


    Overview

    The CP 1243-1 communications processor is used for connecting a SIMATIC S7-1200 to the TeleControl Server Basic control center software via Ethernet, and for safe communication via IP-based networks.

    The CP has the following features:

    • Ethernet-based connection to TeleControl Server basic, e.g. via Internet
    • Data transfer of measured values, control variables, or alarms optimized for becontrol systems
    • Automatic sending of alert emails
    • Data buffering of up to 64,000 values ensures a secure database even with temporary connection failures
    • Secure communication via VPN connections based on IPSec
    • Access protection via Stateful Inspection Firewall
    • Clearly laid out LED signaling for fast and easy diagnostics
    • Compact industrial enclosure in S7-1200 design for mounting on a standard mounting rail
    • Fast commissioning thanks to easy configuration using STEP 7

    Benefits

    • Data security
      The CP 1243-1 has a large buffer for several thousand data values. Downtimes in the transmission b can then be bridged.
    • Fully automatic time stamp
      To enable subsequent and correct archiving of process data in the control system, all data frames are assigned with a time stamp at their place of origin.
    • Fast and flexible data communication
      Operators are therefore quickly provided with alarms, statuses and values from the process, and they can influence process control by entering commands or setpoints at any time.
    • Simple and low-cost engineering
      The cyclic or event-controller transfer of measurements, setpoints or alarms can be implemented in only a few operations and without programming effort.
    • Remote diagnostics
      Saving of traveling and maintenance costs due to cost-effective remote programming, diagnostics, control and monitoring via the Internet
    • Industrial Security
      Securing the system against unauthorized access by means of
      • Central access protection for any devices within an automation cell, e.g. by means of authentication of the network stations
      • Secure remote access via the Internet by means of data encryption (VPN) and data integrity checking

    Area of application

    By using the CP 1243-1, the S7-1200 can be used as a remote terminal unit (substation) in becontrol applications. Typical uses include the collection of measured values in geographically widely distributed outdoor areas (level measurement for water tanks) or centralized opening and closing of valves (oil/gas transport in pipelines).

    • Plants in water, wastewater or environmental sectors:
      • Irrigation systems
      • Drinking water supply
    • Monitoring of power networks for consumption metering and cost control
      • District heating networks
      • Wind farms
    • Plants in the oil and gas sector
      • Oilfield water injection
      • Pipelines
    • Transportation systems
      • Ventilation control in tunnel systems
      • Traffic control

    Regardless of the becontrol features of the CP, it can also be used purely for security applications if the automation system is to be connected securely to a higher-level IT network. This ensures that the SIMATIC S7-1200 is protected against unauthorized access from an Industrial Ethernet network The CP 1243-1 allows secure access via an Industrial Ethernet connection and allows the data transferred between devices or network segments to be protected from manipulation and industrial espionage.

    Cell protection for SIMATIC S7-1200 with CP 1243-1 (Security Integrated)

    Design

    The CP 1243-1 offers all the advantages of the S7-1200 design:

    • Rugged, compact plastic enclosure
    • Easily accessible connection and diagnostics elements, protected by front flaps
    • Simple mounting on the mounting rail of the S7-1200

    The CP 1243-1 is plugged into the left-hand system bus interface of the S7-1200. Power is supplied directly via the S7-1200. No additional wiring is necessary. Any required modems or routers are connected via the Ethernet interface on the underside of the module.

    Functions

    Connection of the SIMATIC S7-1200 to TeleControl Server via cellular radio and DSL internet access

    The CP 1243-1 is a communication module for the S7-1200. The module allows the SIMATIC S7-1200 to be connected as a remote station to TeleControl Server Basic in just a few steps.

    Compleby configurable application through "data point configuration"

    The introduction of the "data point configuration" in STEP 7 dispenses with all programming effort for transfer of data to the control center.

    The data of the CPU relevant to the control center is selected via user-friendly "item browsing" in STEP 7. In a bly-arranged menu, the data transfer beters are then assigned to the data points selected in this way. The cyclic or event-controller transfer of measurements, setpoints or alarms can thus be implemented in only a few operations and without programming effort.

    Data backup

    Data losses are prevented by the data buffering mechanisms integrated in the product.

    In the event of a connection failure, up to 64,000 time-stamped values are buffered. When the connection returns, the buffered values are automatically transferred to the control center in the right order.

    E-mail alerting

    Alert e-mails can be configured for timely provision of stations' states to service or maintenance personnel. If previously defined events (such as threshold violation) should occur, application-specific inbation is sent automatically by e-mail.

    Diagnostics

    The CP 1243-1 offers comprehensive diagnostic options for a quick and inbative analysis of the station status. Elementary diagnostic inbation about the connection to the control center is signaled directly via LEDs at the CP.

    Using STEP 7, comprehensive inbation can be retrieved, such as connection history, buffer status, and the transferred measured values.

    Remote maintenance

    For remote access from the control center to the substation, the CP provides a remote maintenance port in parallel with process operation. This ensures access for monitoring and program changes.

    Interfaces

    The CP 1243-1 has an Ethernet interface to connection to the control center. The S7-1200 can be connected via an existing network or via other media by using additional routers (e.g. SCALANCE M for Internet connection via DSL).

    Power supply

    Extra wiring for the CP power supply is not required. Power is supplied directly via the backplane bus of the S7-1200.

    Technical Specifications

    Order number

    6GK7243-1BX30-0XE0

    Product type designation

    CP 1243-1

    Transmission rate

     

    Transfer rate

     

    •  at the 1st interface

    10 ... 100 Mbit/s

    Interfaces

     

    Number of interfaces acc. to Industrial Ethernet

    1

    Number of electrical connections

     

    •  at the 1st interface acc. to Industrial Ethernet

    1

    •  for power supply

    0

    Type of electrical connection

     

    •  at the 1st interface acc. to Industrial Ethernet

    RJ45 port

    Supply voltage, current consumption, power loss

     

    Type of voltage of the supply voltage

    DC

    Supply voltage 1 from backplane bus

    5 V

    Consumed current

     

    •  from backplane bus at DC at 5 V typical

    0.25 A

    Power loss [W]

    1.25 W

    Permitted ambient conditions

     

    Ambient temperature

     

    •  for vertical installation during operation

    -20 ... +60 °C

    •  for horizontally arranged busbars during operation

    -20 ... +70 °C

    •  during storage

    -40 ... +70 °C

    •  during transport

    -40 ... +70 °C

    Relative humidity at 25 °C without condensation during operation maximum

    95 %

    Protection class IP

    IP20

    Design, dimensions and weight

     

    Module bat

    Compact module S7-1200 single b

    Width

    30 mm

    Height

    110 mm

    Depth

    75 mm

    Net weight

    0.122 kg

    Mounting type

     

    •  35 mm DIN rail mounting

    Yes

    •  wall mounting

    Yes

    Product properties, functions, components general

     

    Number of units

     

    •  per CPU maximum

    3

    Perbance data S7 communication

     

    Number of possible connections for S7 communication

     

    •  Note

    like CPU

    Perbance data becontrol

     

    Suitability for use

     

    •  Node station

    No

    •  substation

    Yes

    •  TIM control center

    No

    Control center connection

    to be used with Telecontrol Server Basic

    •  by means of a permanent connection

    supported

    •  Note

    Connection to Scada system via Telecontrol Server Basic

    Protocol is supported

     

    •  DNP3

    No

    •  IEC 60870-5

    No

    Product function data buffering if connection is aborted

    Yes; 64,000 values

    Number of data points per station maximum

    200

    Perbance data Teleservice

     

    Diagnostics function online diagnostics with SIMATIC STEP 7

    Yes

    Product function

     

    •  program download with SIMATIC STEP 7

    Yes

    •  Remote firmware update

    Yes

    Configuration software

     

    •  required

    STEP 7 Basic/Professional V13 Update 2 + HSP (TIA Portal) or higher

    Product functions Security

     

    Firewall version

    stateful inspection

    Product function with VPN connection

    IPSec

    Type of encryption algorithms with VPN connection

    AES-256, AES-192, AES-128, 3DES-168

    Type of authentication procedure with VPN connection

    Preshared key (PSK), X.509v3 certificates

    Type of bing algorithms with VPN connection

    MD5, SHA-1

    Number of possible connections with VPN connection

    8

    Product function

     

    •  password protection for Web applications

    No

    •  password protection for beservice access

    No

    •  encrypted data transmission

    Yes

    •  ACL - IP-based

    No

    •  ACL - IP-based for PLC/routing

    No

    •  switch-off of non-required services

    Yes

    •  Blocking of communication via physical ports

    No

    •  log file for unauthorized access

    No

    Product functions Time

     

    Protocol is supported

     

    •  NTP

    Yes

    time synchronization

     

    •  from control center

    Yes

     

    6GK5491-2AB00-8AA2

    MEDIA MODULE MM491-2

    • 產(chǎn)品信息細(xì)節(jié)
    •  
    • 技術(shù)數(shù)據(jù)
    •  
    • CAx數(shù)據(jù)
    •  
    • 后續(xù)產(chǎn)品

    技術(shù)數(shù)據(jù)

    產(chǎn)品類型名稱 MM491-2
    SCALANCE X-400 ACCESSORIES, MEDIA MODULE MM491-2, 2 X 100 MBIT/S MULTIMODE BFOC, HOT SWAPABLE, INSCRIPTION FIELD
    接口
    電氣/光學(xué)連接數(shù)量 / 用于網(wǎng)絡(luò)組件和終端設(shè)備 / 最大值 2
    光學(xué)連接數(shù)量 / 用于網(wǎng)絡(luò)組件和終端設(shè)備 / 最大值 2
    100 Mbit/s ST(BFOC) 端口的數(shù)量 / 適用于多模 / 集成的 2
    光學(xué)連接方式 / 用于網(wǎng)絡(luò)組件和終端設(shè)備 ST/BFOC
    可耦合的光學(xué)功率參考 1 mW
    ● 變換器輸出端 / 最小值 -19 dB
    ● 變換器輸出端 / 最大值 -14 dB
    ● 接收器輸入端 / 最大值 -3 dB
    光學(xué)靈敏度參考 1 mW / 接收器輸入端 / 最小值 -32 dB
    阻尼量 / 光纖傳輸距離 / 最低要求 0 dB
    作用范圍 / 光學(xué)接口上 / 視使用的光纖而定 0 ... 5 km
    許可的環(huán)境條件
    環(huán)境溫度
    ● 運行期間 -40 ... +70 °C
    ● 存放期間 -40 ... +80 °C
    ● 運輸期間 -40 ... +80 °C
    相對空氣濕度 / 25 °C 時 / 無冷凝 / 運行期間 / 最大值 95 %
    防護(hù)等級 IP IP20
    結(jié)構(gòu)、尺寸和重量
    結(jié)構(gòu)形式 媒介模塊
    寬度 35 mm
    高度 145 mm
    深度 90 mm
    凈重 0.26 kg
    緊固類型 鎖定
    ● 安裝在介質(zhì)模塊插槽上 是的
    標(biāo)準(zhǔn)、規(guī)范、許可
    標(biāo)準(zhǔn)
    ● 適用于 FM FM3611: Class 1, Divison 2, Group A, B, C, D / T4, Class 1, Zone 2,GroupIIC, T4
    ● 適用于防爆區(qū) EN 60079-0: 2006, EN60079-15: 2005, II 3 G Ex nA II T4, KEMA 07 ATEX0145X
    ● 針對安全性 / CSA 和 UL UL 60950-1,CSA C22.2 編號 60950-1-03
    ● 適用于防爆區(qū) / CSA 和 UL UL 1604 和 UL 2279-15(危險場所),1 類 / 2 級 / A、B、C、D 組 / T4,1類/ 2 區(qū) / IIC 組 / T4
    ● 適用于干擾發(fā)射 EN 61000-6-4:2001(A 級)
    ● 適用于抗干擾性 EN 61000-6-2:2001
    資格證明 EN 61000-6-2:2001, EN 61000-6-4:2001
    ● CE標(biāo)識 是的
    ● C-Tick 是的
    ● KC 許可 是的
    船級社
    ● American Bureau of Shipping Europe Ltd. (ABS) 是的
    ● Bureau Veritas (BV) 是的
    ● Det Norske Veritas (DNV) 是的
    ● Germanischer Lloyd (GL) 是的
    ● Lloyds Register of Shipping (LRS) 是的
    ● Nippon Kaiji Kyokai (NK) 是的
    ● Polski Rejestr Statkow (PRS) 是的
    平均故障間隔時間 (MTBF) / 40 °C 時

    138 y

     

     

     