主營:世界知名品牌的PLC 、DCS 系統(tǒng)備件 模塊
①Allen-Bradley(美國AB)系列產(chǎn)品》
②Schneider(施耐德電氣)系列產(chǎn)品》
③General electric(通用電氣)系列產(chǎn)品》
④Westinghouse(美國西屋)系列產(chǎn)品》
⑤SIEMENS(西門子系列產(chǎn)品)》
⑥銷售ABB Robots. FANUC Robots、YASKAWA Robots、KUKA Robots、Mitsubishi Robots、OTC Robots、Panasonic Robots、MOTOMAN Robots。
⑦estinghouse(西屋): OVATION系統(tǒng)、WDPF系統(tǒng)、MAX1000系統(tǒng)備件。
⑧Invensys Foxboro(??怂共_):I/A Series系統(tǒng),F(xiàn)BM(現(xiàn)場輸入/輸出模塊)順序控制、梯形 邏輯控制、事故追憶處理、數(shù)模轉(zhuǎn)換、輸入/輸出信號處理、數(shù)據(jù)通信及處理等。Invensys Triconex: 冗余容錯控制系統(tǒng)、基于三重模件冗余(TMR)結構的zui現(xiàn)代化的容錯控制器。
⑨Siemens(西門子):Siemens MOORE, Siemens Simatic C1,Siemens數(shù)控系統(tǒng)等。
⑩Bosch Rexroth(博世力士樂):Indramat,I/O模塊,PLC控制器,驅(qū)動模塊等。
◆Motorola(摩托羅拉):MVME 162、MVME 167、MVME1772、MVME177等系列。
安百拓2658347529
29RF5-1103 14, 15
29RF5-6009 14, 15
29RF5-6015 14, 15
29RF5-6103 14, 15
TFM1D 25 MEC120 — MEP100 MERT4
TFM1F 25 MEC120 — MEP100 MERT4
TFM2 23, 25
MEC120 — MEP230 MERT4
TFM2-A7 23
TFM2-A30 23
TFM2-A90 23
TFM3 23, 25
TFM3-7 23
TFM3-90 23
TFM3H 23, 25 MEC120 — MEP230H MERT4
UVM2 23, 25
MEC120 — MEP230 MEUV4
UVM2-A 23, 25
UVM2-A7 23, 25
UVM2-A30 23, 25
UVM2-A90 23, 25
UVM1 23, 25 MEC120 — MEP100 MEUV1
UVM1D 23, 25
UVM1F 25
MEC120 — MEP100 MEUV4
UVM1G 25
OBSOLETE
TYPE AND MODEL NOTES
CURRENT MODEL COMBINATIONS
CONTROL DISPLAY PROGRAMMER AMPLIFIER
50 ? FIREYE PRIMELINE PRODUCTS
NOTES FOR CROSS REFERENCE TABLE
1. Requires new wiring base 60-1466-2 or 60-1386-2.
2. Re-use existing scanner.
3. Add timer if terminal 10 is used for open damper (30 seconds I.C.T.O).
4. Make earth ground connection.
5. E110 requires terminal 13 to be powered on call for heat. If there is no fuel valve end switch, make sure terminal 13 is powered from
terminal 3.
6. Refer to bulletin C-500 for starting circuit change.
7. Replace scanner.
8. Check ignition timing and select appropriate programmer (EP261 if Terminal 5 is used).
9. Check if early spark termination is used, select appropriate programmer with same function.
10. Requires new scanner with UV Self-check (45UV5-1000) and a 6-conductor scanner cable (59-470).
11. Hard-wire new wiring base 60-2206-1.
12. Use 25SU5-5012 in multi-burner applications.
13. Re-use existing scanner (45UV5-1005) if 61-5745-3 Shutter Drive Module is used. Otherwise replace scanner with 45UV5-1009.
14. Evaluate condition of existing wiring base and scanner. If it is appropriate, then hard-wire in a new base and replace the entire scanner
assembly.
15. Check the operating voltage of the existing system. The new control is only available in 120VAC.
16. Evaluate modulating circuit, rewire as required.
17. Evaluate dual scanner application. If possible, use one scanner (D-Series will not work with dual scanners).
18. Supply new wiring base (60-1386-2 or 60-1466-2) and new scanner and rewire.
19. Special for Babcock and Wilcox, original drawings need to be buated and updated as required.
20. If terminals 5 and 6 are used, refer to Bulletin PD-4 page 2, note 2 for instructions to add external relay and use of 51CQ1 start pushbutton.
21. Determine if a flame rod is being used and select an appropriate amplifier. If both a flame rod and an IR scanner are used, either one or
the other must be disconnected or a second control and amplifier must be supplied.
22. Refer to SN #47 to add relay for circulating fan motor.
23. Refer to Bulletin C-4000 for appropriate dipswitch settings.
24. The original UVM-1 control was supplied with a 24V (T and T) connection. If the low voltage circuit is used, then supply a transber
relay. A new wiring base is required.
25. All M-Series controls are interchangeable without wiring changes except UVM1 and UVM2A.
26. If the fuel valve end switch is not present, jumper terminals 3 to 13.
27. Refer to Service Note #65.
FIREYE PRIMELINE PRODUCTS ? 51
GENERAL REFERENCE TABLES
NEMA Standard Classification Codes for Flame Safety Control Enclosures
NEMA 1— General Purpose. For indoor protection, where conditions are not unusually severe.
NEMA 2— Driptight. Designed to exclude falling moisture or dirt. Particularly applicable to cooling rooms, laundries,