主營(yíng):世界知名品牌的PLC 、DCS 系統(tǒng)備件 模塊
①Allen-Bradley(美國(guó)AB)系列產(chǎn)品》
②Schneider(施耐德電氣)系列產(chǎn)品》
③General electric(通用電氣)系列產(chǎn)品》
④Westinghouse(美國(guó)西屋)系列產(chǎn)品》
⑤SIEMENS(西門子系列產(chǎn)品)》
⑥銷售ABB Robots. FANUC Robots、YASKAWA Robots、KUKA Robots、Mitsubishi Robots、OTC Robots、Panasonic Robots、MOTOMAN Robots。
⑦estinghouse(西屋): OVATION系統(tǒng)、WDPF系統(tǒng)、MAX1000系統(tǒng)備件。
⑧Invensys Foxboro(福克斯波羅):I/A Series系統(tǒng),F(xiàn)BM(現(xiàn)場(chǎng)輸入/輸出模塊)順序控制、梯形 邏輯控制、事故追憶處理、數(shù)模轉(zhuǎn)換、輸入/輸出信號(hào)處理、數(shù)據(jù)通信及處理等。Invensys Triconex: 冗余容錯(cuò)控制系統(tǒng)、基于三重模件冗余(TMR)結(jié)構(gòu)的zui現(xiàn)代化的容錯(cuò)控制器。
⑨Siemens(西門子):Siemens MOORE, Siemens Simatic C1,Siemens數(shù)控系統(tǒng)等。
⑩Bosch Rexroth(博世力士樂(lè)):Indramat,I/O模塊,PLC控制器,驅(qū)動(dòng)模塊等。
◆Motorola(摩托羅拉):MVME 162、MVME 167、MVME1772、MVME177等系列。
Emerson Rosemount 0065N34J0150N4580IMXAX8QGBR6
MEP104 Non-recycle on flame fail, 10 second PTFI
MEP105 Non-recycle on flame fail, lockout on air flow open with flame present, 10 FTFI.
MEP106 Relight operation, 12 sec purge, 10 sec PTFI, reset lockout on line power interruption.
MEP107 5 sec purge, 10 second PTFI, 5 minute delay following flame failure. For natural draft atmospheric gas burners
MEP108 Non-recycle operation, 0 sec purge, 15 second PTFI, 10 sec-ond post purge, no FM Approval.
MEP109 Immediate ignition and pilot after limits are closed, 10 sec PTFI (fixed), 10 sec MTFI, intermittent pilot, non-recycle on flame fail.
MEP100P Relight operation, 10 sec PTFI, 15 second post purge.
MEP130 Relight operation, 30 sec PTFI, no agency approvals
MEP141 30 sec purge, 5 sec PTFI, 15 sec post purge, Prove air at start, 8 sec pilot stabilization, non-recycle on flame fail.
MEP149 30 sec purge, 5 sec PTFI, 90 sec post purge, prove air at start, 8 sec pilot stabilization, non-recycle on flame fail.
MEP230 Selectable purge timing, PTFI timing, recycle/non-recycle, post purge, prove air open at start
MEP230H Same as MEP230 with 8 second pilot stabilization
MEP235 Same as MEP230 with lockout on air flow open 10 seconds after the start of a cycle, selectable recycle/nonrecycle lockout on air
flow open after flame is proven and dedicated lockout after loss of flame.
MEP236 Same as MEP230 with additional 6 second igniter on time with main fuel. To be used with intermittent pilot only.
MEP238 Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start. Ignition de-energized 3 seconds
after pilot detected. Provides 8 second pilot stabilization period.
MEP290 Same as MEP230 except selectable post purge is 0 or 90 seconds.
MEP437 Valve proof of closure, selectable purge, PTFI timing, intermittent or interrupted, recycle / non-recycle operation, reset by power
interruption of manual reset.
MEP536 Same as MEP236, 10 second trial for ignition, run-check switch, will not lockout on air flow open during purge.
MEP537 Selectable purge, PTFI, post purge, prove open at start, recycle/non-recycle (with one recycle on flame fail), 10 sec MTFI.
MEP560 Same as MEP230H, 10 second main trial for ignition, run-check switch
MEP561 Same as MEP560 without pilot stabilization
MEP562 Same as MEP560, lockout on loss of air flow, non-recycle operation only
MEP564 Same as MEP560 except purge timings are 7 30, 60, and 240 (4 minutes) seconds.
PART NUMBER MicroM Series MEC320 Chassis for use with MEP300 and 600 Series Programmers
MEC320 MicroM chassis with local reset; 120 VAC, 50/60 Hz, provides independent relay outputs on terminals 3 and 4.
For use with MEP300 and MEP600 series programmers.
MEC320R MicroM MEC320 chassis with remote reset. For use with MEP300 and 600 series programmers.
MEC320D MicroM MEC320 chassis with alpha-numeric display interface to ED510. For use with MEP300 and 600 series programmers.
MEC320C MicroM MEC320 chassis with interface to E500 Communication Interface and Modbus capability.
For use with MEP300 and 600 series programmers.
MEC320RC MicroM MEC320 chassis with remote reset capability, interface to ED510, interface to E500 Comm. Interface, and
Modbus capability. For use with MEP300 and 600 series programmers.
MEC320RD MicroM MEC320 chassis with remote reset capability and interface to ED510.
For use with MEP300 and 600 series programmers.
MEC320TS MicroM MEC320 chassis with remote communications and independent relay output.
For use with MEP696 programmer only.
MEC480 MicroM chassis with local reset; 230 VAC, 50/60 Hz, pro-vides independent relay outputs on terminals 3 and 4.
For use with MEP300 and 600 series programmers.
FIREYE PRIMELINE PRODUCTS ? 33
PART NUMBER Programmers for use with MEC320 / MEC480 Chassis
MEP300 Relight operation on main flame fail, lockout on PTFI and MTFI flame fail, 10 sec PTFI (fixed),
5 sec pilot proving, 5 sec MTFI.
MEP304 5 sec purge, 10 sec PTFI (fixed), 5 sec pilot proving, 10 sec MTFI,
interrupted pilot, interrupted ignition, non-recycle on flame fail.
MEP397 15 sec purge, provides interrupted ignition, interrupted pilot, non re-cycle on flame fail.
MEP696 Provides selectable PTFI, selectable baud rate, and selectable recycle / non-recycle operation.
For use with MEC320TS chassis only.
MEP697 Selectable TFI timing, purge timing, post purge, prove open at start, and recycle / non-recycle on flame fail. Includes 5 sec pilot
proving, early spark termination, 5 sec MTFI, and interrupted pilot.
PART NUMBER MicroM Amplifier Models (common for all controls)
MEUV1 UV amplifier, 0.8 second FFRT, uses UV1A, UV2, UV8A and 45UV3-1050 scanners
MEUV4 UV amplifier, 3 second FFRT, uses UV1A, UV2, UV8A and 45UV3-1050 scanners
MEUVS1 UV Self-Check amplifier, 0.8 second FFRT, uses 45UV5-1007, -1008, -1009 scanners
MEUVS4 UV Self-Check amplifier, 3 second FFRT, uses 45UV5-1007, -1008, -1009 scanners
MERT1 Flame Rod / Photocell amplifier, 0.8 second FFRT, uses 69ND1 or 45CM1
MERT4 Flame Rod / Photocell amplifier, 3 second FFRT, uses 69ND1 or 45CM1
MEIR1 Infrared amplifier, 0.8 second FFRT, uses 48PT2 scanner
MEIR4 Infrared amplifier, 3 second FFRT, uses 48PT2 scanner
MECD1 Cadmium sulfide amplifier, 0.8 second FFRT, uses CS1A5 scanner
MECD4 Cadmium sulfide amplifier, 3 second FFRT, uses CS1A5 scanner
PART NUMBER Optional Plug-In Board Module (common for all controls)
MED1 Standard local reset switch
MED2 Same as MED1 with display output
MED3 Same as MED1 with remote reset