Accessories
Record Plus? FC 100
Lugs and Lug Kits
Single Lug List Price Lug Kit List Price
Amp Range Wire Range Strip Length Product No. GO-135H Product No. (Set of 3) GO-135H
15-20A 14-10 Cu/Al .40-.50” FCAL12 緯軒機(jī)電3.25 FCALK12 緯軒機(jī)電9.00
25-60A 10-4 Cu/Al .40-.50” FCAL13 緯軒機(jī)電3.25 FCALK13 緯軒機(jī)電9.00
70-100A 4-1/0 Cu/Al .40-.50” FCAL14 緯軒機(jī)電3.25 FCALK14 緯軒機(jī)電9.00
External Accessories
Components: Parts
1
1-18 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Molded Case Circuit Breakers
Accessories
Record Plus? FE 250
FE Rating Plugs List Price
Trip Curve CT Rating Rated Current Product No. GO-135H
25A 20 A FERP3B0020 緯軒機(jī)電106.00
25 A FERP3B0025 緯軒機(jī)電106.00
30 A FERP3D0030 緯軒機(jī)電106.00
40 A FERP3D0040 緯軒機(jī)電106.00 60A 50 A FERP3D0050 緯軒機(jī)電106.00
60 A FERP3D0060 緯軒機(jī)電106.00
70 A FERP3G0070 緯軒機(jī)電106.00
80 A FERP3G0080 緯軒機(jī)電106.00
DES-200 90 A FERP3G0090 緯軒機(jī)電106.00 125A 100 A FERP3G0100 緯軒機(jī)電106.00
110 A FERP3G0110 緯軒機(jī)電106.00
125 A FERP3G0125 緯軒機(jī)電106.00
150A 150 A FERP3H0150 緯軒機(jī)電106.00
175 A FERP3K0150 緯軒機(jī)電106.00
200 A FERP3K0200 緯軒機(jī)電106.00 250A 225 A FERP3K0225 緯軒機(jī)電106.00
250 A FERP3K0250 緯軒機(jī)電106.00
Bell Alarm
Contact List Price
Configuration Contact Rating Wire leads Product No. GO-135H
1 NO (Form A) 5A @ 277 VAC, #16 AWG FABAM10W 緯軒機(jī)電154.00
0.3A @ 125 VDC
1 NC (Form B) 5A @ 277 VAC, #16 AWG FABAM01W 緯軒機(jī)電154.00
0.3A @ 125 VDC
UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
instruction sheet DEH-40324 for wire lead colors.
Internal and External Accessories
Neutral Grounds and Sensors
Neutral Current Sensors
For grounded neutral system ground fault applications
List Price
Breaker Type Ampere Rating Product Number GO-135S
150 TSRG201 緯軒機(jī)電532.00
200 TSRG202 緯軒機(jī)電532.00
300 TSRG203 緯軒機(jī)電532.00 J 400 TSRG204 緯軒機(jī)電532.00
500 TSRG205 緯軒機(jī)電532.00
600 TSRG206 緯軒機(jī)電532.00
800 TSKG408 緯軒機(jī)電532.00
K 1000 TSKG410 緯軒機(jī)電532.00
1200 TSKG412 緯軒機(jī)電532.00 Neutral Current Sensor
Breaker Frames & Ratings Plugs
Insulated Case Circuit Breakers
Circuit Breakers History/Timeline
GE Insulated Case Circuit Breakers History/Timeline
1965 GE pioneered the design of insulated case circuit breakers when it introduced the original
Power Break? circuit breaker.
1995 GE introduced Power Break? II insulated case circuit breakers, the vanguard of a new age in reliable, flexible
and easy-to-use circuit protection.
Evolution of the GE Trip Unit
1965 Dual Magnetic Trip
1975 VersaTrip Solid State Trip
1979 VersaTrip Mod 2 Solid State Trip
1979 Magnetrip-Dual Mag
1979 SelecTrip
1982 MicroVersaTrip?
1988 MicroVersaTrip? RMS 9
1989 MicroVersaTrip? RMS 9 / Epic
1994 MicroVersaTrip? Plus/PM
1995 Enhanced MicroVersaTrip? Plus/PM
1996 Power Break? II MicroVersaTrip? Plus/PM
1997 Power Break? II Powerplus
2009 EnbliGuard? TU
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-19
to change without notice
This catalog contains replacement parts, retrofits, accessories,
and older generation products. For current generation products,
please see the GE BuyLog? or Control Catalog.
Components: Parts
1
1-20 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Enhanced MicroVersaTrip?, Rating Plug Selection
Power Break? II Rating Plug Selection
Enhanced
MicroVersaTrip? Plus
Power+ Trip and Enhanced
Power+ Trip Unit Ground MicroVersaTrip? PM
Unit Standard Fault Rating Trip Unit
Frame Sensor Current Rating Plugs Plugs Rating Plugs
Size Rating Rating List Price 緯軒機(jī)電89.00 List Price 緯軒機(jī)電747.00 List Price 緯軒機(jī)電89.00
(Amperes) (Amperes) (Amperes) GO-245A GO-245A GO-245A
100 TR2C100 TR2C100GF TR2B100
200 150 TR2C150 TR2C150GF TR2B150
200 TR2C200 TR2C200GF TR2B200
150 – – TR4B150
800 200 TR4C200 TR4C200GF TR4B200
225 TR4C225 TR4C225GF TR4B225 400 250 TR4C250 TR4C250GF TR4B250
300 TR4C300 TR4C300GF TR4B300
400 TR4C400 TR4C400GF TR4B400
300 – – TR8B300
400 TR8C400 TR8C400GF TR8B400
450 TR8C450 TR8C450GF TR8B450
800-1600 800 500 TR8C500 TR8C500GF TR8B500
600 TR8C600 TR8C600GF TR8B600
700 TR8C700 TR8C700GF TR8B700
800 TR8C800 TR8C800GF TR8B800
400 – – TR10B400
1000 600 TR10C600 TR10C600GF TR10B600
800 TR10C800 TR10C800GF TR10B800
1000 TR10C1000 TR10C1000GF TR10B1000
1600 600 – – TR16B600
800 TR16C800 TR16C800GF TR16B800
1600 1000 TR16C1000 TR16C1000GF TR16B1000
1100 TR16C1100 TR16C1100GF TR16B1100
1200 TR16C1200 TR16C1200GF TR16B1200
1600 TR16C1600 TR16C1600GF TR16B1600
750 – – TR20B750
800 – – TR20B800
1000 TR20C1000 TR20C1000GF TR20B1000
2000 2000 1200 TR20C1200 TR20C1200GF TR20B1200
1500 TR20C1500 TR20C1500GF TR20B1500
1600 TR20C1600 TR20C1600GF TR20B1600
2000 TR20C2000 TR20C2000GF TR20B2000
400 – – TR10B400
600 TR10C600 TR10C600GF TR10B600 1000 800 TR10C800 TR10C800GF TR10B800
1000 TR10C1000 TR10C1000GF TR10B1000
750 – – TR20B750
800 – – TR20B800
1000 TR20C1000 TR20C1000GF TR20B1000 2500 2000 1200 TR20C1200 TR20C1200GF TR20B1200
1500 TR20C1500 TR20C1500GF TR20B1500
1600 TR20C1600 TR20C1600GF TR20B1600
2000 TR20C2000 TR20C2000GF TR20B2000
1600 TR25C1600 TR25C1600GF TR25B1600
2500 2000 TR25C2000 TR25C2000GF TR25B2000
2500 TR25C2500 TR25C2500GF TR25B2500
1200 – – TR30B1200
1600 – – TR30B1600
3000 3000 2000 TR30C2000 TR30C2000GF TR30B2000
2500 TR30C2500 TR30C2500GF TR30B2500
3000 TR30C3000 TR30C3000GF TR30B3000
1600 TR40C1600 TR40C1600GF TR40B1600
2000 TR40C2000 TR40C2000GF TR40B2000
4000 4000 2500 TR40C2500 TR40C2500GF TR40B2500
3000 TR40C3000 TR40C3000GF TR40B3000
3600 TR40C3600 TR40C3600GF TR40B3600
4000 TR40C4000 TR40C4000GF TR40B4000
MicroVersaTrip? and MicroVersaTrip? PM Rating Plug
Trip Indicator Product List Price
L/ST/1 Ground Fault Number GO-245A
– – TARGET00 緯軒機(jī)電60.00
? – TARGET01 緯軒機(jī)電140.00
? ? TARGET02 緯軒機(jī)電160.00
Power+ Target Module
Power+ trip units are designed to accept an optional field-installable
target module. The target module indicates long-time pickup, battery
status, trip unit health status, and whether a breaker trip was
caused by an overload, a short circuit or a ground fault. Target
?modules are available with or without ground fault indication.
Power+ Trip Target Module
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-21
to change without notice
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
120 – SPE120R 緯軒機(jī)電1671.00 SPE120 緯軒機(jī)電1838.00
240 – SPE240R 緯軒機(jī)電1869.00 SPE240 緯軒機(jī)電2056.00
– 24 SPE024R 緯軒機(jī)電1869.00 SPE024 緯軒機(jī)電2056.00
– 48 SPE048R 緯軒機(jī)電1869.00 SPE048 緯軒機(jī)電2056.00
– 72 SPE072R 緯軒機(jī)電1869.00 SPE072 緯軒機(jī)電2056.00
– 125 SPE125R 緯軒機(jī)電1869.00 SPE125 緯軒機(jī)電2056.00
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
120 – SPRCS120R 緯軒機(jī)電286.00 SPRCS120 緯軒機(jī)電315.00
240 – SPRCS240R 緯軒機(jī)電286.00 SPRCS240 緯軒機(jī)電315.00
– 24 SPRCS024R 緯軒機(jī)電286.00 SPRCS024 緯軒機(jī)電315.00
– 48 SPRCS048R 緯軒機(jī)電286.00 SPRCS048 緯軒機(jī)電315.00
– 72 SPRCS072R 緯軒機(jī)電286.00 SPRCS072 緯軒機(jī)電315.00
– 125 SPRCS125R 緯軒機(jī)電286.00 SPRCS125 緯軒機(jī)電315.00
Electrical Operator
Remote Close Solenoid
This accessory provides an electrically operated solenoid which, when energized, closes
the breaker. It is suitable for control interlock schemes in which manual closing capability
would not be convenient or desirable. The breaker is provided with a manual close
button, which can be replaced by the Hidden "ON" Button accessory and/or sealed using
the Limited Access Pushbutton Cover accessory. The remote close accessory is continuously
rated and has an anti-pump feature, which prevents a motor operated breaker
from repeatedly closing into a fault. Closing control voltage must be removed and re-applied
for each breaker closure.
Remote Close Solenoid
Accessories—Stationary and Draw-out Breakers
The complete line of Power Break? II breaker accessories may be either factory or field
installed to meet user needs. The electronic shunt trip, the bell alarm, the bell alarm with
mechanical lockout, and the undervoltage release modules are drop-in from the front of
the breaker, interchangeable across all frames, and require no field internal wiring or
breaker disassembly. Auxiliary switch modules are available in groups of 4, 8 or 12,
NO/NC single-pole, double-throw (SPDT) switches. Their installation simply involves
removal of breaker cover, installation of the switch module, routing of wiring and installation
of the pre-wired terminal block and re-installation of the cover. Auxiliary switches
are also interchangeable across all Power Break? II breaker frames.
Electrical Operator
The electrical operator mounts inside the front cover of the manually operated breaker.
This accessory can be added to any Power Break? II breaker in the factory or the field
to provide electrical spring charging and charge indication. For remote closing, the
remote close solenoid must be priced and ordered separaby. All breakers are
prewired to dedicated secondary terminals for easy field installation. When electrical
operation is used, either a shunt trip or an undervoltage release must be ordered and
priced separaby.
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
1-22 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Shunt Trip
The shunt trip accessory is an electronic module, which provides remote control capability
to open the circuit breaker. When activated, the shunt trip module sends a signal to
the trip unit to open the breaker. This allows the trip unit to record, display, distinguish
and communicate (in MicroVersaTrip? PM trip units) that the opening event was initiated
by the shunt trip device. The shunt trip is continuously rated and requires no cut-off
switch. When energized, the shunt trip supplies +24Vdc power to the trip unit to power
the display.
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
– 12 SPST012R 緯軒機(jī)電301.00 SPST012 緯軒機(jī)電328.00
24 24 SPST024R 緯軒機(jī)電301.00 SPST024 緯軒機(jī)電328.00
48 48 SPST048R 緯軒機(jī)電301.00 SPST048 緯軒機(jī)電328.00
120 125 SPST120R 緯軒機(jī)電301.00 SPST120 緯軒機(jī)電328.00
208 – SPST208R 緯軒機(jī)電301.00 SPST208 緯軒機(jī)電328.00
240 250 SPST240R 緯軒機(jī)電301.00 SPST240 緯軒機(jī)電328.00
480 – SPST480R1 緯軒機(jī)電301.00 SPST4801 緯軒機(jī)電328.00
600 – SPST600R1 緯軒機(jī)電301.00 SPST6001 緯軒機(jī)電328.00
1Kit contains externally mounted transber.
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
12 SPSTL012R 緯軒機(jī)電401.00 SPSTL012 緯軒機(jī)電428.00
24 24 SPSTL024R 緯軒機(jī)電401.00 SPSTL024 緯軒機(jī)電428.00
48 48 SPSTL048R 緯軒機(jī)電401.00 SPSTL048 緯軒機(jī)電428.00
120 125 SPSTL120R 緯軒機(jī)電401.00 SPSTL120 緯軒機(jī)電428.00
208 – SPSTL208R 緯軒機(jī)電401.00 SPSTL208 緯軒機(jī)電428.00
240 250 SPSTL240R 緯軒機(jī)電401.00 SPSTL240 緯軒機(jī)電428.00
480 – SPSTL480R1 緯軒機(jī)電401.00 SPSTL480 緯軒機(jī)電428.00
600 – SPSTL600R1 緯軒機(jī)電401.00 SPSTL600 緯軒機(jī)電428.00
1Kit contains externally mounted transber.
Shunt Trip Module
Shunt Trip with Lockout Module
The shunt trip with lockout is identical to the regular shunt trip, but when energized, it
will also prevent closure of an "open" breaker by mechanically blocking both manual and
electrical closing. When energized, the closing springs will not discharge, the movable
contacts will not move; the contacts are "kiss free."
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-23
to change without notice
Undervoltage Release Module
The undervoltage release is an electronic module used to open the circuit breaker when
the monitored voltage drops below 35-60% of its rated value. The undervoltage release
"resets" when the monitored voltage is re-established allowing the circuit breaker to reclose
(the sealing voltage of the UVR is 60-85% of its rated voltage).
An undervoltage release trip operation is produced by the MicroVersaTrip? Plus unit in
response to a signal from the undervoltage release module. This allows the trip unit to
record, display, distinguish and communicate (in MicroVersaTrip? PM trip units) that the
breaker opening event was due to undervoltage release. Operation of the undervoltage
release module will prevent breaker contact closure, i.e. "kiss-free" operation. When
energized, the undervoltage release supplies +24 Vdc power to the trip unit to power
the display.
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
24 – SPUV024ACR 緯軒機(jī)電301.00 SPUV024AC 緯軒機(jī)電328.00
48 – SPUV048ACR 緯軒機(jī)電301.00 SPUV048AC 緯軒機(jī)電328.00
120 – SPUV120ACR 緯軒機(jī)電301.00 SPUV120AC 緯軒機(jī)電328.00
208 – SPUV208ACR 緯軒機(jī)電301.00 SPUV208AC 緯軒機(jī)電328.00
240 – SPUV240ACR 緯軒機(jī)電301.00 SPUV240AC 緯軒機(jī)電328.00
480 – SPUV480ACR1 緯軒機(jī)電301.00 SPUV480AC1 緯軒機(jī)電328.00
600 – SPUV600ACR1 緯軒機(jī)電301.00 SPUV600AC1 緯軒機(jī)電328.00
– 12 SPUV012DCR 緯軒機(jī)電301.00 SPUV012DC 緯軒機(jī)電328.00
– 24 SPUV024DCR 緯軒機(jī)電301.00 SPUV024DC 緯軒機(jī)電328.00
– 48 SPUV048DCR 緯軒機(jī)電301.00 SPUV048DC 緯軒機(jī)電328.00
– 125 SPUV125DCR 緯軒機(jī)電301.00 SPUV125DC 緯軒機(jī)電328.00
– 250 SPUV250DCR 緯軒機(jī)電301.00 SPUV250DC 緯軒機(jī)電328.00
1Kit contains externally mounted transber.
Undervoltage Release Module
Bell Alarm (Alarm Only)
The bell alarm module is used to signal breaker "tripped" status to other accessories
(e.g., external alarm devices, indicating lights, relays, or logic circuits) for remote indication
and interlocking functions. The bell alarm response is configurable by means of
rear-mounted DIP switches on the trip unit. The bell alarm can be made to operate in
response to an overcurrent (including ground fault) or protective relay trip and/or a
shunt trip operation, and/or operation of the undervoltage release module. It is not
actuated as a result of normal breaker "ON/OFF" operation.
This module provides a visual, mechanical pop-out target, which protrudes through the
face of the circuit breaker door when it operates. The bell alarm may be reset manually
by depressing the mechanical target, or automatically by closing the breaker.
The bell alarm is provided with one SPDT switch with control power duty contacts as
shown in the auxiliary switch accessories.
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
240 125-250 SPBAA240R 緯軒機(jī)電124.00 SPBAA240 緯軒機(jī)電135.00
600 125-250 SPBAA600R1 緯軒機(jī)電124.00 SPBAA6002 緯軒機(jī)電135.00
2600 Vac module not UL Listed.
Bell (Alarm Only)
List Price
Debion Product Number GO-245B
Time Delay Module
(0.1 to 1.0 second delay) SPUVTD 緯軒機(jī)電430.00
Time Delay Module for UVR
The time delay module prevents nuisance tripping due to momentary loss of voltage.
The module has 120 Vac b and 125 Vdc output and must be used with the 125 Vdc UVR.
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
1-24 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Bell Alarm With Lockout
The bell alarm with lockout module combines both the bell alarm and a manual lockout
function. The bell alarm switch operates identically to the standard bell alarm module,
except that the mechanical pop-out target must be manually reset before the breaker
can be closed.
Operation of the bell alarm with lockout module can be independently set by means
of setting the DIP switches at the rear of the trip unit. Current rating of the single SPDT
switch is identical to the auxiliary switch accessories.
Ratings Ratings Field Installable List Price Factory Installed List Price
Vac Vdc Product Number GO-245B Product Number GO-245B
240 125-250 SPBAL240R 緯軒機(jī)電124.00 SPBAL240 緯軒機(jī)電135.00
600 125-250 SPBAL600R1 緯軒機(jī)電124.00 SPBAL6001 緯軒機(jī)電135.00
1600 Vac module not UL Listed. Bell Alarm with Mechanical Reset Lockout
Auxiliary Switch
An auxiliary switch signals the circuit breaker’s primary contact b (i.e., OPEN or
CLOSED) to other devices, such as indicating lights, relays or logic circuits. This enables
the user to provide remote indication, interlocking or control operations as a function of
breaker primary contact b. The auxiliary switch operation is independent of the
b by which the breaker is opened or closed. The auxiliary switch does not distinguish
between a "tripped" or "open" condition. The auxiliary switch contacts follow the
main breaker contacts on opening and precede them on closing.
Auxiliary switch modules are available with 4, 8 or 12 NO/NC (SPDT) switches for control
power duty ac/dc ratings. When ordered for field installation, an auxiliary switch module
comes pre-wired to its own terminal board, which mounts with one screw to the left of
the breaker. A special accessory, available for draw out breakers, comes pre-wired to the
?breaker secondary disconnect. All switch ratings are 6A at 120V-600 Vac, 1/2A at 125
Vdc and 1/4A at 250 Vdc.
Auxiliary Switches for Stationary Breakers
No. of SPDT
Ratings Ratings Switch Elements Field Installable List Price Factory Installed List Price
Vac Vdc (Contacts) Product Number GO-245B Product Number GO-245B
240 125-250 4 SPAS240AB4R 緯軒機(jī)電268.00 SPAS240AB4 緯軒機(jī)電293.00
240 125-250 8 SPAS240AB8R 緯軒機(jī)電564.00 SPAS240AB8 緯軒機(jī)電616.00
240 125-250 12 SPAS240AB12R 緯軒機(jī)電651.00 SPAS240AB12 緯軒機(jī)電710.00
600 125-250 4 SPAS600AB4R1 緯軒機(jī)電268.00 SPAS600AB41 緯軒機(jī)電293.00
600 125-250 8 SPAS600AB8R1 緯軒機(jī)電564.00 SPAS600AB81 緯軒機(jī)電616.00
1600 Vac module not UL Listed.
Auxiliary Switch with
Pre-wired Secondary Terminals
for Stationary Breaker
Auxiliary Switch with
Pre-wired Secondary Terminals
for Draw-out Breaker
Auxiliary Switches for Draw-out Breakers
No. of SPDT
Ratings Ratings Switch Elements Field Installable List Price Factory Installed List Price
Vac Vdc (Contacts) Product Number GO-245B Product Number GO-245B
240 125-250 4 SPAS240AB4DR 緯軒機(jī)電551.00 SPAS240AB4D 緯軒機(jī)電576.00
240 125-250 8 SPAS240AB8DR 緯軒機(jī)電847.00 SPAS240AB8D 緯軒機(jī)電899.00
240 125-250 12 SPAS240AB12DR 緯軒機(jī)電934.00 SPAS240AB12D 緯軒機(jī)電993.00
600 125-250 4 SPAS600AB4DR1 緯軒機(jī)電551.00 SPAS600AB4D1 緯軒機(jī)電576.00
600 125-250 8 SPAS600AB8DR1 緯軒機(jī)電847.00 SPAS600AB8D1 緯軒機(jī)電899.00
1600 Vac module not UL Listed.
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-25
to change without notice
Mechanical Operations Counter
The mechanical operations counter is mounted behind the front cover of the breaker. It
is viewable through a rectangular knockout b opening in the breaker cover. It is a
five-digit, non-resettable counter, which is actuated each time the breaker is opened by
any means.
Field Installed List Price Factory Installed List Price
Product Number GO-245B Product Number GO-245B
SPCOUNTERR 緯軒機(jī)電100.00 SPCOUNTER 緯軒機(jī)電125.00
Hidden "ON" Button
The hidden "ON" button is assembled to the mechanism behind an unlabeled, false
?pushbutton. Manual closing of the breaker can only be perbed by means of a small
?diameter rod. This accessory is used to limit access to the manual "ON" control to
authorized personnel.
Field Installed List Price Factory Installed List Price
Product Number GO-245B Product Number GO-245B
SPPBNONR 緯軒機(jī)電64.00 SPPBNON 緯軒機(jī)電64.00
Maintenance/Repair Parts
Debion Product Number List Price GO Schedule
Top Cover and Rating Labels SPBII-REPLACE_COVER1 緯軒機(jī)電600.00 148C
Replacement MVT Door 10054335P1 緯軒機(jī)電20.00 148G
Replacement Powerplus Door 10054335P2 緯軒機(jī)電16.00 148G
Stop Block Kit w/Installation Tool SPBUMPERKIT 緯軒機(jī)電175.00 148C
Stop Block Kit (no tools) SPBUMPNTKIT 緯軒機(jī)電90.00 148C
1Special handling and order entry required to preserve UL Listing of breaker.
Contact Post Sale Service for additional details of special process.
Limited Access Pushbutton Cover
This accessory limits access to "ON/OFF" control of a breaker to authorized personnel.
The pushbutton cover accessory consists of transparent hinged covers that can be individually
sealed to the limited access assembly. Both the "ON" and "OFF" buttons can be
pilot drilled to allow use of a 1/8" rod to operate either one or both pushbuttons.
Field Installed List Price Factory Installed List Price
Product Number GO-245B Product Number GO-245B
SPPBCOVERR 緯軒機(jī)電80.00 SPPBCOVER 緯軒機(jī)電90.00
Mechanical Operations Counter
Breaker with limited access pushbutton
cover assembly installed
Activating the breaker closing
mechanism through the hole in the
Hidden “ON” Button
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
1-26 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Key Interlock Provisions
The key interlock provision enables the user to mount a one- to four-cylinder, narrowfaced,
Kirk-type FN or Superior customer-supplied lock on the face of the breaker. This
accessory provides mounting for key interlocks that are furnished by the customer. The
key interlock provision works in conjunction with the padlock provision. The key interlock
extends a lever through the padlock hasp when the key is turned to the key removal or
bolt extended b. Additionally, the accessory provides a hasp for mounting three
padlocks with 1/4" to 3/8" diameter shanks.
Padlock Provisions (Standard)
Padlocking provisions are standard on all Power Break? II circuit breakers. When the
breaker is in the open b, and the padlock hasp is raised at least 1/4", the breaker
?cannot be closed mechanically or electrically. The hasp accepts up to three padlocks
with 1/4" to 3/8" diameter shanks.
Walking Beam Interlocks—Stationary Breakers Only
Walking beam interlocks are mechanical devices used to prevent two adjacent circuit
breakers from both being in the "ON" or closed b at the same time. However, both
breakers can be in the "OFF" or open b.
Door Interlock
The door interlock provides interlocking of the circuit breaker compartment’s hinged
door so that the breaker must be in the "OFF" b before the door can be opened.
The door interlock is defeatable with a small tool to allow authorized access.
Circuit Breaker List Price
Envelope Size (Amperes) Product Number GO-245B
800, 1600 and 2000 SPWB20 緯軒機(jī)電1228.00
3000 SPWB30 緯軒機(jī)電1228.00
4000 SPWB40 緯軒機(jī)電1228.00
Product Numbers, Key Interlock Provisions
Circuit Breaker Number of Field Installed List Price Factory Installed List Price
Envelope Size (Amps) Key Locks Product Number GO-245B Product Number GO-245B
All 1 to 4 SPK4R 緯軒機(jī)電355.00 SPK4 緯軒機(jī)電426.00
Field Installed List Price Factory Installed List Price
Product Number GO-245B Product Number GO-245B
SPDILR 緯軒機(jī)電173.00 SPDIL 緯軒機(jī)電208.00
Key Interlock Kit (lock not included)
Door Interlock
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary and Draw-out Breaker Accessories
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-27
to change without notice
Lug Adapter Kits
Kits pre-mount to bus structure allowing cabling or bussing to be completed prior to
breaker mounting. Accepts either lugs or crimp-type connector terminals. Kit includes
adapter and hardware for either a three-pole line-side, or a three-pole load-side connection.
(Lugs not included).
Circuit Breaker Max Rating Product Lug Max. Cables Wire Range List Price
Envelope Size (Amperes) (Amperes) Number Per Kit Per Pole kcmil Cu/AI GO-245B
400 TPLUG106 1 1 (2) #2 2-600 緯軒機(jī)電18.50
600 TPLUG206 1 2 (2) #2 2-600 緯軒機(jī)電27.50 800 800 TPLUG308 1 3 (3) 300-750 緯軒機(jī)電32.00
800 TPLUG1084 1 3 3/0-800 緯軒機(jī)電23.00
1600 800 TPLUG1084 1 6 3/0-800 緯軒機(jī)電23.00
1600 TPLUG408 1 4 500-800 緯軒機(jī)電39.00
2000 TPLUG1084 1 6 3/0-800 緯軒機(jī)電23.00
2000 800 TSLUG08 9 3 3/0-800 緯軒機(jī)電274.00
1200 TSLUG12 12 4 3/0-800 緯軒機(jī)電296.00
1600 TSLUG16 15 5 3/0-800 緯軒機(jī)電345.00
2000 TSLUG20 18 6 3/0-800 緯軒機(jī)電383.00
3000 2500 TSLUG25 21 7 3/0-800 緯軒機(jī)電418.00
3000 TSLUG30 27 9 3/0-800 緯軒機(jī)電630.00
4000 4000 TSLUG40 27 9 3/0-800 緯軒機(jī)電1045.00
4For use with adapter kit only. See table above.
Frame Product Suitable for List Price
Rating (Amperes) Number use with up to: GO-245B
3 TPLUG108 Lugs or
800 TPLUGA08 3 crimp Lugs1 per pole 緯軒機(jī)電78.50
6 TPLUG108 lugs or
1600 TPLUGA162 6 crimp Lugs1 per pole 緯軒機(jī)電389.00
6 TPLUG108 Lugs or
2000 SPLUGA203 6 crimp Lugs1 per pole 緯軒機(jī)電487.00
1Anderson No. VCEL-075-12H1 or equivalent
2T-Studs - TP16FCA - included with adapter
3T-Studs - SP20FCA - included with adapter
Lug Kits
Kits accept Cu/AI wire and are suitable for direct mounting to the breaker. When ordering
Type TPLUG kits, order one kit per line or load pole. Example: A complete set of lugs
for the line side of an 800A frame, 400A trip breaker would be Qty 3-TPLUG106 lugs.
When ordering TSLUG kits order one kit per line or load side; TSLUG kits require use of
T-studs. Example: A complete set of lugs for a 3000A frame, 2500A trip breaker would be
Qty 1-TSLUG25. T-Studs would also be required.
2000 Ampere Power Break? II breaker with
SPLUGA20 lug adapter kit and 18 lugs
(TPLUG108)
Type TPLUG206
Type TPLUG408
Type TPLUG308
Type TSLUG20
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary Breaker Mounting Kits
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
1-28 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
T-Studs
T-studs mount directly to the breaker, and can be rotated for either vertical or horizontal
bus connection. 4000 ampere T-studs are for vertical bus bars only. Product number
includes one stud. Both copper and aluminum T-studs are tin-plated.
Trimplate
Factory Installed Field Installable List Price
Product Number Product Number GO-245B
SPTRIMPLATE SPTRIMPLATER 緯軒機(jī)電64.00
T-Studs—Front Connected Breaker
Circuit Breaker Max. Rating List Price
Frame Size (Amperes) (Amperes) Product Number GO-245B
800 800 SP08FCA1 緯軒機(jī)電36.00
800 800 SP08FCC2 緯軒機(jī)電36.00
2000 800-2000 SP20FCA1 緯軒機(jī)電49.00
2000 800-2000 SP20FCC2 緯軒機(jī)電49.00
2500 2000 SPS20FCA1 緯軒機(jī)電48.75
2500 2500 SPS25FCC2 緯軒機(jī)電51.50
3000 3000 SPS30FCC2 緯軒機(jī)電181.50
4000 4000 SPS40FCC2 緯軒機(jī)電240.50
4000 4000 SPS40LFCC2,3 緯軒機(jī)電395.00
T-Studs—Back Connected Breaker
Circuit Breaker Max. Rating List Price
Frame Size (Amperes) (Amperes) Product Number GO-245B
2500 2000 SPS20BCA1,4 緯軒機(jī)電48.75
2500 2500 SPS25BCC2,4 緯軒機(jī)電51.50
3000 3000 2,5 緯軒機(jī)電181.50
1Aluminum
2Copper
3Extra long stud. Alternate with SPS40FCC for ease of installation.
4Six T-studs at no charge when ordered with breaker
5Supplied with integral T-stud
2000A Breaker with "T" Studs Mounted
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Stationary Breaker Mounting Kits, Wall Mounted Enclosures, Floor Mounted Enclosures
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-29
to change without notice
MicroVersaTrip? Portable Test Kit
The test kit product number TVRMS2 is a portable, battery-powered,
test kit which provides for trip unit health checks and functional
trip and no-trip tests. It also provides defeat of the
ground-fault function and can be used in conjunction with highcurrent
test equipment. The test kit can be used to provide +24V
power to the trip unit for cold set-up and viewing of trip targets.
This test kit is for use with RMS-9, Epic, MicroVersaTrip? Plus and
MicroVersaTrip? PM trip units. The kit uses six rechargeable ni-cad
or standard alkaline "D" cells supplied by the customer. Kit can
also be powered by 120 Vac source.
List Price
Debion Product Number GO-245B
Portable Test Kit TVRMS2 緯軒機(jī)電3000.00
MicroVersaTrip? Portable Power Pack
The handheld MicroVersaTrip? portable battery pack provides
an independent power source for Enhanced MicroVersaTrip? Plus
and MicroVersaTrip? PM trip units as an alternative to the TVRMS2
test set. The power pack is used to power up the trip unit to set or
adjust trip set points when the breaker is on the bench or otherwise
not powered up. It connects to the trip unit through
the rating plug test jack. It requires three (3) standard 9 Vdc
alkaline batteries (not included).
List Price
Debion Product Number GO-245B
MicroVersaTrip? Plus and PM
Portable Power Pack TVPBP 緯軒機(jī)電75.00
POWER LEADER? Power Supplies
Power supply for furnishing 24Vdc control power for
MicroVersaTrip? Plus and PM trip units.
System Requirements Product List Price
Debion (price separaby) Number G0-104A
1.5 ampere power supply
Price one PLPS4G01 for
each line-up. 45 trip units Input power, 100VA
and 100 ft. maximum. (85-265Vac or 100-370Vdc) PLPS4G01 緯軒機(jī)電1250.00
POWER LEADER? Voltage Conditioner
Conditions and scales 120Vac to 1.76 Vac for use by the trip unit
for voltage sensing. Provides transient protection. Voltage conditioners
require isolation PTs.
System Requirements Product List Price
Debion (price separaby) Number G0-104A
Supplies isolated bus
voltage signal to One set of 3 voltage conditioners
MicroVersaTrip? PM required for each voltage sensing 緯軒機(jī)電200.00
trip units. b. PTs also required. PLVC1G01 per set
Neutral Current Sensors1
Circuit Breaker Neutral Sensor
Breaker Frame Sensor Rating Rating or Tap Product List Price
(Amperes) (Amperes) Settings (Amperes) Number GO-245B
200 200 TSVG302 緯軒機(jī)電266.00
800 400 400/200 TSVG304A 緯軒機(jī)電266.00
400 600/3002 TSVG306A 緯軒機(jī)電266.00
800-1600 800 800/400 TSVG308A 緯軒機(jī)電266.00
1000 800/4002 TSVG808A 緯軒機(jī)電266.00
1600 1000 1000/500 TSVG810A 緯軒機(jī)電266.00
1600 1200/6002 TSVG812A 緯軒機(jī)電266.00
1600 1600/1000 TSVG816A 緯軒機(jī)電266.00
2000 2000 2000/1000 TSVG820A 緯軒機(jī)電266.00
1000 800/4002 TSVG808A 緯軒機(jī)電266.00
1000 1000/500 TSVG810A 緯軒機(jī)電266.00
1000 1200/6002 TSVG812A 緯軒機(jī)電266.00
3000 1000 1600/10002 TSVG816A 緯軒機(jī)電266.00
2000 2000/1200 TSVG820A 緯軒機(jī)電266.00
2500 2500/1800 TSVG825A 緯軒機(jī)電266.00
3000 3000/2400 TSVG830A 緯軒機(jī)電266.00
4000 4000 4000/3000 TSVG940A 緯軒機(jī)電266.00
1Match neutral current sensor rating (or tap setting) to circuit breaker sensor rating.
2For use with multiple source ground fault protection schemes. Rating does not
match MicroVersaTrip? Plus or PM frame sensor.
Neutral Current Sensor
Rating Plug Removal Tool
List Price
Product Number GO-135S
TRTOOL 緯軒機(jī)電12.00
Reference
Instructions GEH-6492
Reference
Instructions GEH-5946
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Neutral Current Sensors and POWER LEADER Accessories
Components: Parts
1
1-30 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Features
—Draw-outs through 4000 amperes are UL Listed, 100% rated
—Modular design for simplified installation—6 basic sizes—800, 1600, 2000, 2500,
3000, 4000—5 inch pole centers
—Screw racking mechanism provides positive racking motion
—Self aligning primary and secondary disconnects
—Four b draw-out—engaged, test, disengaged, fully withdrawn—
simplifies system testing and inspection
—Breaker b indicator bly shows breaker b
—Provisions for padlocking breaker in test or disengaged b
—Mechanical interlock logic prevents movement of a closed breaker
—Suitable for reverse feeding
Debion
The draw-out assembly consists of a substructure housing unit designed as a compact
self-supporting unit and a draw-out breaker which must be ordered separaby. The
substructure contains mounting holes, self-supporting male plugs and extendable rails,
and can be ordered separaby for installation in your switchboard or enclosure.
The Power Break? II draw-out breaker is a self-contained, heavy-duty assembly designed
to offer simplified breaker inspection without de-energizing the main bus structure.
The draw-out breaker comes complete with racking mechanism drive, wheels, primary
and secondary disconnects and cooperating interlock systems.
Accessories such as dead-front shutters, by-pass switches (b switches), and
padlock devices are available and field installable.
OEM Substructures
Substructures are available for both standard and Hi-Break Power Break? II breakers.
Holes are provided for bolting on a shelf or supports. Holes are also provided in the primary
stabs for bolting to busbars or terminal lugs. Substructure secondary disconnects
are ordered and priced separaby. Order Hi-Break substructures for use with Power
Break? II switches.
Frame Rating Standard Break List Price Hi-Break List Price
(Amperes) Product Number GO-245B Product Number GO-245B
800 SPSDOS08 緯軒機(jī)電671.00 SPHDOS08 緯軒機(jī)電724.00
1600 SPSDOS16 緯軒機(jī)電1300.00 SPHDOS16 緯軒機(jī)電1403.00
2000 SPSDOS20 緯軒機(jī)電1892.00 SPHDOS20 緯軒機(jī)電2040.00
2500 SPSDOS25 緯軒機(jī)電2048.00 SPHDOS25 緯軒機(jī)電2207.00
3000 SPSDOS30 緯軒機(jī)電2739.00 SPHDOS30 緯軒機(jī)電2951.00
4000 SPSDOS40 緯軒機(jī)電6916.00 SPHDOS40 緯軒機(jī)電7455.00
List Price
Location Product Number GO-245B
Substructure SPDOSD36S 緯軒機(jī)電283.00
Breaker1 SPDOSD36B 緯軒機(jī)電283.00
1Order for replacement only. Included and factory wired with draw-out breaker.
Draw-out Breaker in Substructure
1600-ampere substructure for
standard break breaker
Secondary Disconnect for Draw-out Breakers
Control wiring is connected through draw-out secondary disconnects in the "TEST" and
?"CONNECTED" bs only. Up to 72 control circuits are possible through 36 b
plug-style secondary disconnect blocks factory mounted to each side of draw-out
breakers. One substructure disconnect (SPDOSD36S) must be ordered for each breaker
when accessories or communications are used. When auxiliary switches are used along
with any other electrical accessory or communications, two disconnects must be ordered.
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Draw-out Breaker Accessories
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-31
to change without notice
Racking Tool
The racking tool is a drive wrench with a square 1/2" socket
that engages the racking mechanism of the draw-out breaker.
One racking tool is supplied with every five draw-out breakers
at no charge.
List Price
Frame Rating Product Number GO-245B
All TDORT 緯軒機(jī)電70.00
Mechanical Interlocks
Mechanical interlocks provide the same function as the walking
beam accessory for stationary breakers, except they are used
with two draw-out breakers: mounted on common compartment
centerline, in either the same vertical section or adjacent vertical
sections.
List Price
Envelope Size Product Number GO-245B
800-2000 SPDOWB20 緯軒機(jī)電1310.00
2500-4000 SPDOWB40 緯軒機(jī)電1310.00
Rail Kit
This field installable rail kit may be used to shorten the two
standard OEM substructure rails by 3-1/2 inches.
List Price
Product Number GO-245B
SPRAILS 緯軒機(jī)電310.00
Position Switch
Provides positive indication when the draw-out breaker or switch
primary contact fingers have been fully withdrawn from the main
bus connections. Switch contacts change state only after the
primary fingers are fully disconnected when the breaker is being
moved from the CONNECTED b through the TEST b
and into the DISCONNECTED b.
May be used as part of a safety interlocking system in addition
to the visual indicator on the draw-out substructure. The Position
Switch accessory does not indicate either the TEST or CONNECTED
b. The switch assembly mounts on the stationary frame
and the actuator mounts to the carriage. Switch contacts are
rated at 10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc.
Number of List Price
Switch Elements Product Number GO-245B
2 NO/2 NC SDOPS2L 緯軒機(jī)電177.00
4 NO/4 NC SDOPS4L 緯軒機(jī)電256.00
6 NO/6 NC SDOPS6L 緯軒機(jī)電336.00
Shutter Kit
This field installable kit provides shutters used to prevent unintentional
contact with potentially live primary disconnect stabs when
a breaker is racked out of an energized switchboard compartment.
List Price
Frame Rating Product Number GO-245B
800-2000A SPDSS20 緯軒機(jī)電501.00
3000A SPDSS30 緯軒機(jī)電501.00
4000A SPDSS40 緯軒機(jī)電501.00
By-Pass Switch
Provides positive indication that the draw-out breaker or switch
?primary contact fingers are fully connected to the main bus in the
substructure. Switch contacts change states only after the primary
fingers are fully connected when the breaker is being
moved from the DISCONNECTED b through the TEST b
and into the CONNECTED b.
May be used to provide control circuit continuity or downstream
?signaling that the draw-out breaker is connected in addition to
the visual b indicator on the draw-out substructure. The
By-pass switch accessory does not indicate either the TEST or
DISCONNECTED b. The switch assembly mounts on the stationary
frame and the actuator mounts to the carriage. Switch
contacts are rated at 10A at 600 Vac, 0.75A at 125 Vdc, and
0.25A at 250 Vdc.
Number of List Price
Switch Elements Product Number GO-245B
2 NO/2 NC TDOBP2L 緯軒機(jī)電177.00
4 NO/4 NC TDOBP4L 緯軒機(jī)電256.00
6 NO/6 NC TDOBP6L 緯軒機(jī)電336.00
Racking Padlock Provision
The racking padlock provides a means for the user to prevent racking
tool engagement, thereby preventing movement of the breaker
between the DISCONNECTED, TEST and CONNECTED bs.
List Price
Frame Rating Product Number GO-245B
All TDOPC 緯軒機(jī)電46.00
Lifting Bar
The lifting bar provides a means of safely lifting a draw-out circuit
breaker. A chain hook can be attached to the central hole in the
lifting bar or a 1" diameter black iron pipe can be put through the
two holes above the hooks, allowing two people to carry the
breaker below waist level from either side of the breaker.
One lifting bar is supplied with every five draw-out breakers at
no charge.
List Price
Frame Rating Product Number GO-245B
All TDOLB 緯軒機(jī)電104.00
Insulated Case Circuit Breakers
Power Break? II Circuit Breaker Accessories
Draw-out Breakers and Accessories
All devices UL Listed for factory or field installation except where noted.
Components: Parts
1
1-32 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Neutral Current (800: 1 ratio) Sensors
Inside Core Thermal Rating Weight Product List Price
Dimensions Construction (Amperes) (Lbs.) Number GO-142
2.5” Dia. Solid 1600 3 TGS0002 緯軒機(jī)電460.00
5” Dia. Solid 2500 4 TGS0005 緯軒機(jī)電731.00
8” Dia. Solid 3000 7 TGS0008 緯軒機(jī)電856.00
4” x 8” Split 4000 15 TGS0408 緯軒機(jī)電1439.00
8” x 8” Split 4000 25 TGS0808 緯軒機(jī)電1482.00
Neutral Current Sensor - Solid
Neutral Current Sensor - Split
Disconnect Switches and Operating Mechanisms
High-Pressure Contact Switch
With Integral Ground Fault Devices, 800-4000 Amperes, 600 Vac Max., UL File. No. E-51827
Components: Parts
1
Prices and data subject Aftermarket Catalog www.geelectrical.com 1-33
to change without notice
Field Installed Lugs Kits 800-1600 Ampere
Switches–Direct Mounting
Field installed only. Kits consist of lugs and hardware for direct
?mounting to switch terminal straps (multiple-hole tang lugs) or lugs
for mounting to 800 ampere terminal adapter kit. Order three kits
for three-pole line or load end. For 1600-ampere, copper conductors
must be used.
Ampere Rating Accessory Wire Range Product List Price
Type Cu/Al Number GO-145A
800A Lug Kit Line (3) 300-750 THPCLUG308 緯軒機(jī)電63.50 & Lug Kit Load
1200A, 1600A Lug Kit Line (4) 500-800 kcmil TPLUG408 緯軒機(jī)電39.001
1200A, 1600A Lug Kit Load (4) 500-800 kcmil THPCLUG408 緯軒機(jī)電77.50
1GO-245B
Field Installed Lugs Kits 2000-4000 Ampere
Switches–Direct Mounting
Field installed only. To terminate line and load cables, must be
used in conjunction with bus-connection adapter on page 7-20 (T
Studs). Each lug kit includes lugs, straps and hardware for threephase
line or load connections. Each cable lug accommodates
1–3/0 Cu or 250 kcmil Al to 800 kcmil Cu-Al. Accepts Anderson
VersaCrimp when lugs are removed from straps.
No. of Lugs per Pole Product List Price
Ampere Rating Line or Load End Number GO-245B
2000A 6 TSLUG20 緯軒機(jī)電383.00
2500A 7 TSLUG25 緯軒機(jī)電418.00
3000A 9 TSLUG30 緯軒機(jī)電630.00
4000A 11 TSLUG40 緯軒機(jī)電1045.00
Field Installed T Studs
Field installed only. May be used to adapt line and load terminals
of switch to vertical or horizontal bus arrangements. Three
required for line or load connections on three-phase bus. Accepts
either lugs, bolts, or Anderson VCEL VersaCrimp.
Basic Switch Product List Price
Rating (Amperes) Number GO-145A
800 THPC08FCA2 緯軒機(jī)電71.00
1200-1600 TP16FCA 緯軒機(jī)電113.00
2000 TS20FCA 緯軒機(jī)電113.00
2500 TS25FCA 緯軒機(jī)電119.00
3000 TS30FCA 緯軒機(jī)電418.00
4000 (5)TS40FCA 緯軒機(jī)電562.00
4000 (1)TS40LFCA3 緯軒機(jī)電789.00
2For vertical bussing only.
3For center pole, line terminal.
Disconnect Switches and Operating Mechanisms
High-Pressure Contact Switch
Accessories, UL Listed
Section 2: Switchgear
Table of Contents
Switchgear
2
Prices and data subject Aftermarket Catalog www.geelectrical.com 2-1
to change without notice
History/Timeline .............................................................................2-2
Low Voltage Power and DC Circuit Breakers .............................2-3
Gerapid High Speed DC Circuit Breakers ..........................................2-3
AK and AKR Low Voltage Power
Circuit Breakers.........................................................................................2-4
Trip Unit Conversion Kits...........................................................................2-5
Overview – EnbliGuard? TU and ProTrip?
Conversion Kits.....................................................................................2-5
ProTrip? Trip Unit Conversion Kits Selection Guide ...............2-7
ProTrip? Rating Plugs.........................................................................2-11
EnbliGuard? TU Trip Unit Conversion
Kits Selection Guide.........................................................................2-12
EnbliGuard? TU Trip Rating Plugs................................................2-16
EnbliGuard? TU Trip Unit Conversion Kit
Accessories and Hardware..........................................................2-17
Trip Unit Conversion Kit Accessories ...........................................2-18
Electrically Operated Racking Device .............................................2-20
Technical Specifications.....................................................................2-21
Reference Publications............................................................................2-22
Asbestos Free Arc Quencher Replacement Kits..........................2-23
This catalog contains replacement parts, retrofits, accessories,
and older generation products. For current generation products,
please see the GE BuyLog? or Control Catalog.
Switchgear
2-2 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Low Voltage Power and DC Circuit Breakers
Low Voltage Switchgear History/Timeline
GE Low Voltage Switchgear History/Timeline
1930’s-50 AE/AL Manufactured from 1930’s(?) to the early 1950’s
1951-75 AKD
AK = Power Circuit Breaker Equipment
D = Drawout circuit breaker construction
Manufactured 1951 - 1975, all bolted copper bus design, all breakers drawout, AK-1, 2, 3 - 15 / 25 / 50 / 75 / 100.
4000A max bus rating, 4 levels of bus, ring bus used in all feeder sections, main bus has provisions for future extension,
sections in outdoor construction did not line up in the front, indoor construction has extended frames to allow
the fronts of the sections to align. Indoor depths 49” (225 / 600A breakers), 59” (1600A breakers), 63” (3200 / 4000A
breakers). Breakers had ratcheting drawout mechanism – open door drawout. Painted ANSI 61 light gray, manufactured
in Philadelphia 1951 - mid-60’s, Bbington mid-60’s - 1975. Breaker compartment was a welded assembly,
equipment frame was bolted. Breaker boxes were stacked to make a vertical section with equipment frame around
the breaker boxes. No bus compartment barriers, open bus design. Ring silver plating on bolted connections.
1951-60’s AKS Stationary version of AKD, manufactured 1951 - 60’s
1960-77 AKD-5 Manufactured 1960 - 1977, aluminum bus with “flash-butt welded” copper to aluminum at bolted connections.
AK-2A, 3A -25 / 50 / T50 / 75 / 100 (“A” signifies AKD-5 drawout). Pull-lanyard drawout mechanism on early
design, replaced by single jackscrew mechanism and then replaced by double jack-screw mechanism. Closed-door
drawout with inner house breaker compartment. 60” deep frame with 18” extension option. Outdoor protected
aisle uses 60” deep indoor frame. Two bus levels available, ring bus used at 4000A. Welded / riveted frame, bus
compartment barriers, line/load separation barriers on mains and ties, isolation barriers on transber transitions,
copper runbacks on feeder breakers, ring silver plating on copper, aluminum bus unplated (welded connections).
Painted sand gray (beige), some instrument doors painted blue. AKR-30/50 in 22” wide sections introduced
in AKD-5 construction in early -70’s.
1977-81 AKD-6 Manufactured in Salisbury, NC 1977 - 1981. Some AKD-5 construction built in Salisbury ’75 - ’77 and nameplated
as AKD-6. No flash-butt welded aluminum to copper. Aluminum bus is tin plated and bolted at shipping splits (welded
everywhere else). Copper bus design has ring silver plating at bolted joints. Introduced AKR-75 / 100. Stab-and-finger
connections on 3200 and 4000A breakers versus round primary disconnect on AKD-5. Uses inner-house drawout breaker
compartment. Tuning fork primary disconnect (extrusion) on 800 - 2000A breaker compartments. Copper feeder breaker
runbacks. 60” deep frames with 18” optional rear extension. Painted ANSI 61 light gray. Breakers have ECS or SST trip units.
1981- AKD-8 Manufactured 1981 to present. Model 1 & 2 has extruded vertical bus. Model 2 introduced in 1983 to accommodate
present automated wiring programs and harness routing. Model 3 introduced in 1991 using flat bar vertical bus. Breakers use
MicroVersa Trip 9, RMS9, EPIC, MVT Plus, MVT PM trip units. Aluminum bus removed from design in 1996 in favor of standard
tin-plated copper bus (silver plating optional). Field convertible space compartment design added to allow empty
compartments to be modified to functioning breaker compartment without modifications to vertical bus.
1998- AKD-10 Introduced March 1998 as the successor to AKD-8. Manufactured along with AKD-8 for 1998 and 1999. Uses only
present WavePro low voltage power circuit breakers. Same dimensions as AKD-8. Only changes from AKD-8 are in the front breaker
compartment — new drawout rails, breaker door, secondary disconnects instrument panel. No need for Remote Display
for trip unit since WavePro breaker has trip unit in the escutcheon. AKD-10 can match & line-up with AKD-8 without a transition
(for indoor and outdoor construction). Same bus structure, frame, options, layouts and breaker stacking as AKD-8.
2005- Enblisys Introduced October 2005 as a new platb for low voltage switchgear. Uses non-automatic EnbliGuard
present breakers (similar to WavePro except no current sensors, no trip unit, and limited accessories). Enblisys uses redundant
components for highest reliability and maximum up-time. Redundant CPU’s perb all protection, metering, control,
and monitoring functions. Other redundant components of the system include 2 UPS’s, 2 network communication
switches for internal communication, 2 control power throwover relays, 2 control power sources (120vAC). Each breaker
cubicle is provided with an EnbliGuard Messenger, which is the interface between the CPU’s and the circuit breaker
operating mechanisms. The Messenger perbs A/D and D/A conversions plus provides back-up overcurrent proteciton
for the breaker if all control power and communications are lost.
Equipment construction is the same as AKD-10 switchgear (frame, bussing, drawout cubicles, etc). Enblisys does
not replace AKD-10. Both product lines are currently being produced.
2
Switchgear
2
Prices and data subject Aftermarket Catalog www.geelectrical.com 2-3
to change without notice
Low Voltage Power and DC Circuit Breakers
Gerapid High Speed DC Circuit Breakers
Technical Data for Rectifier Circuit Breaker Models 8007R and 10007R
Breaker type Gerapid 8007R Gerapid 1007R
Arc chute type 1x2 1x3 1x2 1x3
Rated current In/A 6,000 6,000 8,000 8,000
Rated operating voltage Ue/V 800 1,200 800 1,200
Rated insulation voltage Ui/V 2,000 2,000 2,000 2,000
120 min./A 7,200 7,200 9,600 9,600
Short time current 2 min./A 8,000 8,000 16,000 16,000
20 sec./A 12,000 12,000 24,000 24,000
Mechanical endurance ops. 10,0001 10,0001 10,0001 10,0001
Total weight approx. kg 220 220 220 220
1With regular maintenance 100,000 ops.
Figure 3. Gerapid 8007R and 10007R Rectifier CB, 1X2 Arc Chute, 800VDC
(Dimensions in mm)
Switchgear
2
2-4 Aftermarket Catalog www.geelectrical.com Prices and data subject
to change without notice
Low Voltage Power and DC Circuit Breakers
AK and AKR Low Voltage Power Circuit Breakers
New AK and AKR low voltage power circuit breakers are available for replacement and
retrofill needs. The following circuit breakers are available:
AK Circuit Breaker
AC Voltage Rating Frame Size Short-circuit Ratings — RMS Symmetrical KA
60 Hertz Breaker Type (Amps) With Instantaneous Trip Without Instantaneous Trip
AK-25 600 22 22
600 AK-50 1600 42 42
AK-50H 1600 65 65
AK-25 600 30 22
480 AK-50 1600 50 50
AK-50H 1600 65 65
AK-25 600 42 22
240 AK-50 1600 65 50
AK-50H 1600 85 65
AKR Circuit Breaker
AC Voltage Rating Frame Size Short-circuit Ratings — RMS Symmetrical KA
50/60 Hertz Breaker Type (Amps) With Instantaneous Trip Without Instantaneous Trip
AKR-30 800 30 30
AKR-30H 800 42 42
600 AKR-50 1600 42 42
AKR-50H 1600 65 65
AKRT-50H 2000 65 65
AKR-75 3200 65 65
AKR-100 4000 85 85
AKR-30 800 30 30
AKR-30H 800 42 42
480 AKR-50 1600 50 50
AKR-50H 1600 65 65
AKRT-50H 2000 65 65
AKR-75 3200 65 65
AKR-100 4000 85 85
AKR-30 800 42 30
AKR-30H 800 50 42
240 AKR-50 1600 65 50
AKR-50H 1600 65 65
AKRT-50H 2000 65 65
AKR-75 3200 85 65
AKR-100 4000 130 85
Contact your local GE sales representative for price and delivery. Be prepared to provide full
nameplate data from your existing low voltage switchgear lineup.
AK-25 Breaker
AKR-30H Breaker
Switchgear
2
Prices and data subject Aftermarket Catalog www.geelectrical.com 2-5
to change without notice
AK-25 Breaker with EnbliGuard? TU Trip Unit
Low Voltage Power and DC Circuit Breakers
Trip Unit Conversion Kits
EnbliGuard? TU Conversion Kits
GE offers a complete line of trip unit upgrade kits for low voltage
power circuit breakers manufactured by GE, as well as by
Westinghouse, I-T-E, and Allis-Chalmers. These conversion kits
contain everything necessary to convert an old-style electromechanical
or solid-state trip unit to today's latest electronic,
digital technology—including the addition of metering, protective
relay, waveb capture, RELT, and communication functions.
All conversion kits designed by GE are tested to ANSI C37.59
standards for each breaker type so customers have the
assurance of safe, reliable operation.
Features and Benefits–All Kits
—Kit includes everything needed in one compact package
—Full-range of interchangeable rating plugs
—Trip targets for quick identification of overload, short circuit,
and ground fault trips
—Sealable, see-through cover to prevent unauthorized access to
trip unit settings
—Portable Trip Unit Test Kits; GTUTK20 and TVRMS2
—Eliminate costly downtime due to nuisance tripping
—Improved power system coordination and protection
—Extend life and function of existing breakers and low voltage
equipment
EnbliGuard? TU Conversion Kits
—True RMS sensing with a sampling rate of 48 samples per cycle
with the ability to Waveb capture 4 cycles prior and 4 cycles
after an event
—Long Time, Short Time, and Instantaneous Standard on all trip
units. S and I switchable on ANSI breakers
—Large backlit LCD screen, view all currents on one screen
—Trip settings and trip target inbation stored in non-volatile
memory
—On-board lithium battery (field replaceable) for cold set-up and
reading trip targets
—Status and Event Log, view the last 10 events
—Health Status LED and Thermal Memory
—Comm port for interface with set-up software and to download
Waveb
—Optional metering, relaying, communications, ZSI - I, ground
fault (trip & alarm), and fused shaped curves
—Plug and Play with previous generation of RMS9, EPIC, MVT and
Enhanced MVT Trip Units
ProTrip? Conversion Kits
—Cost-effective upgrade with standard adjustable long time,
short time, instantaneous, and defeatable ground fault functions
—Simple-to-use rotary switches for selecting the trip unit pickup
and delay settings