国产精品久久久久久久久,四季AV一区二区夜夜嗨,日韩精品无码中文字幕电影,www.五月婷婷.com

產(chǎn)品簡(jiǎn)介
U003 美國(guó)通用GE電氣
U003 美國(guó)通用GE電氣
產(chǎn)品價(jià)格:¥0
上架日期:2019-11-19 17:03:06
產(chǎn)地:歐美
發(fā)貨地:廈門(mén)
供應(yīng)數(shù)量:不限
最少起訂:1件
瀏覽量:236
資料下載:暫無(wú)資料下載
其他下載:暫無(wú)相關(guān)下載
詳細(xì)說(shuō)明
    Accessories
    Record Plus? FC 100
    Lugs and Lug Kits
    Single Lug List Price Lug Kit List Price
    Amp Range Wire Range Strip Length Product No. GO-135H Product No. (Set of 3) GO-135H
    15-20A 14-10 Cu/Al .40-.50” FCAL12 緯軒機(jī)電3.25 FCALK12 緯軒機(jī)電9.00
    25-60A 10-4 Cu/Al .40-.50” FCAL13 緯軒機(jī)電3.25 FCALK13 緯軒機(jī)電9.00
    70-100A 4-1/0 Cu/Al .40-.50” FCAL14 緯軒機(jī)電3.25 FCALK14 緯軒機(jī)電9.00
    External Accessories
    Components: Parts
    1
    1-18 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Molded Case Circuit Breakers
    Accessories
    Record Plus? FE 250
    FE Rating Plugs List Price
    Trip Curve CT Rating Rated Current Product No. GO-135H
    25A 20 A FERP3B0020 緯軒機(jī)電106.00
    25 A FERP3B0025 緯軒機(jī)電106.00
    30 A FERP3D0030 緯軒機(jī)電106.00
    40 A FERP3D0040 緯軒機(jī)電106.00 60A 50 A FERP3D0050 緯軒機(jī)電106.00
    60 A FERP3D0060 緯軒機(jī)電106.00
    70 A FERP3G0070 緯軒機(jī)電106.00
    80 A FERP3G0080 緯軒機(jī)電106.00
    DES-200 90 A FERP3G0090 緯軒機(jī)電106.00 125A 100 A FERP3G0100 緯軒機(jī)電106.00
    110 A FERP3G0110 緯軒機(jī)電106.00
    125 A FERP3G0125 緯軒機(jī)電106.00
    150A 150 A FERP3H0150 緯軒機(jī)電106.00
    175 A FERP3K0150 緯軒機(jī)電106.00
    200 A FERP3K0200 緯軒機(jī)電106.00 250A 225 A FERP3K0225 緯軒機(jī)電106.00
    250 A FERP3K0250 緯軒機(jī)電106.00
    Bell Alarm
    Contact List Price
    Configuration Contact Rating Wire leads Product No. GO-135H
    1 NO (Form A) 5A @ 277 VAC, #16 AWG FABAM10W 緯軒機(jī)電154.00
    0.3A @ 125 VDC
    1 NC (Form B) 5A @ 277 VAC, #16 AWG FABAM01W 緯軒機(jī)電154.00
    0.3A @ 125 VDC
    UL Listed for field installation. Accessories are prewired from the factory with 36 inch long leads. Reference
    instruction sheet DEH-40324 for wire lead colors.
    Internal and External Accessories
    Neutral Grounds and Sensors
    Neutral Current Sensors
    For grounded neutral system ground fault applications
    List Price
    Breaker Type Ampere Rating Product Number GO-135S
    150 TSRG201 緯軒機(jī)電532.00
    200 TSRG202 緯軒機(jī)電532.00
    300 TSRG203 緯軒機(jī)電532.00 J 400 TSRG204 緯軒機(jī)電532.00
    500 TSRG205 緯軒機(jī)電532.00
    600 TSRG206 緯軒機(jī)電532.00
    800 TSKG408 緯軒機(jī)電532.00
    K 1000 TSKG410 緯軒機(jī)電532.00
    1200 TSKG412 緯軒機(jī)電532.00 Neutral Current Sensor
    Breaker Frames & Ratings Plugs
    Insulated Case Circuit Breakers
    Circuit Breakers History/Timeline
    GE Insulated Case Circuit Breakers History/Timeline
    1965 GE pioneered the design of insulated case circuit breakers when it introduced the original
    Power Break? circuit breaker.
    1995 GE introduced Power Break? II insulated case circuit breakers, the vanguard of a new age in reliable, flexible
    and easy-to-use circuit protection.
    Evolution of the GE Trip Unit
    1965 Dual Magnetic Trip
    1975 VersaTrip Solid State Trip
    1979 VersaTrip Mod 2 Solid State Trip
    1979 Magnetrip-Dual Mag
    1979 SelecTrip
    1982 MicroVersaTrip?
    1988 MicroVersaTrip? RMS 9
    1989 MicroVersaTrip? RMS 9 / Epic
    1994 MicroVersaTrip? Plus/PM
    1995 Enhanced MicroVersaTrip? Plus/PM
    1996 Power Break? II MicroVersaTrip? Plus/PM
    1997 Power Break? II Powerplus
    2009 EnbliGuard? TU
    Components: Parts
    1
    Prices and data subject Aftermarket Catalog www.geelectrical.com 1-19
    to change without notice
    This catalog contains replacement parts, retrofits, accessories,
    and older generation products. For current generation products,
    please see the GE BuyLog? or Control Catalog.
    Components: Parts
    1
    1-20 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Insulated Case Circuit Breakers
    Power Break? II Circuit Breaker Accessories
    Enhanced MicroVersaTrip?, Rating Plug Selection
    Power Break? II Rating Plug Selection
    Enhanced
    MicroVersaTrip? Plus
    Power+ Trip and Enhanced
    Power+ Trip Unit Ground MicroVersaTrip? PM
    Unit Standard Fault Rating Trip Unit
    Frame Sensor Current Rating Plugs Plugs Rating Plugs
    Size Rating Rating List Price 緯軒機(jī)電89.00 List Price 緯軒機(jī)電747.00 List Price 緯軒機(jī)電89.00
    (Amperes) (Amperes) (Amperes) GO-245A GO-245A GO-245A
    100 TR2C100 TR2C100GF TR2B100
    200 150 TR2C150 TR2C150GF TR2B150
    200 TR2C200 TR2C200GF TR2B200
    150 – – TR4B150
    800 200 TR4C200 TR4C200GF TR4B200
    225 TR4C225 TR4C225GF TR4B225 400 250 TR4C250 TR4C250GF TR4B250
    300 TR4C300 TR4C300GF TR4B300
    400 TR4C400 TR4C400GF TR4B400
    300 – – TR8B300
    400 TR8C400 TR8C400GF TR8B400
    450 TR8C450 TR8C450GF TR8B450
    800-1600 800 500 TR8C500 TR8C500GF TR8B500
    600 TR8C600 TR8C600GF TR8B600
    700 TR8C700 TR8C700GF TR8B700
    800 TR8C800 TR8C800GF TR8B800
    400 – – TR10B400
    1000 600 TR10C600 TR10C600GF TR10B600
    800 TR10C800 TR10C800GF TR10B800
    1000 TR10C1000 TR10C1000GF TR10B1000
    1600 600 – – TR16B600
    800 TR16C800 TR16C800GF TR16B800
    1600 1000 TR16C1000 TR16C1000GF TR16B1000
    1100 TR16C1100 TR16C1100GF TR16B1100
    1200 TR16C1200 TR16C1200GF TR16B1200
    1600 TR16C1600 TR16C1600GF TR16B1600
    750 – – TR20B750
    800 – – TR20B800
    1000 TR20C1000 TR20C1000GF TR20B1000
    2000 2000 1200 TR20C1200 TR20C1200GF TR20B1200
    1500 TR20C1500 TR20C1500GF TR20B1500
    1600 TR20C1600 TR20C1600GF TR20B1600
    2000 TR20C2000 TR20C2000GF TR20B2000
    400 – – TR10B400
    600 TR10C600 TR10C600GF TR10B600 1000 800 TR10C800 TR10C800GF TR10B800
    1000 TR10C1000 TR10C1000GF TR10B1000
    750 – – TR20B750
    800 – – TR20B800
    1000 TR20C1000 TR20C1000GF TR20B1000 2500 2000 1200 TR20C1200 TR20C1200GF TR20B1200
    1500 TR20C1500 TR20C1500GF TR20B1500
    1600 TR20C1600 TR20C1600GF TR20B1600
    2000 TR20C2000 TR20C2000GF TR20B2000
    1600 TR25C1600 TR25C1600GF TR25B1600
    2500 2000 TR25C2000 TR25C2000GF TR25B2000
    2500 TR25C2500 TR25C2500GF TR25B2500
    1200 – – TR30B1200
    1600 – – TR30B1600
    3000 3000 2000 TR30C2000 TR30C2000GF TR30B2000
    2500 TR30C2500 TR30C2500GF TR30B2500
    3000 TR30C3000 TR30C3000GF TR30B3000
    1600 TR40C1600 TR40C1600GF TR40B1600
    2000 TR40C2000 TR40C2000GF TR40B2000
    4000 4000 2500 TR40C2500 TR40C2500GF TR40B2500
    3000 TR40C3000 TR40C3000GF TR40B3000
    3600 TR40C3600 TR40C3600GF TR40B3600
    4000 TR40C4000 TR40C4000GF TR40B4000
    MicroVersaTrip? and MicroVersaTrip? PM Rating Plug
    Trip Indicator Product List Price
    L/ST/1 Ground Fault Number GO-245A
    – – TARGET00 緯軒機(jī)電60.00
    ? – TARGET01 緯軒機(jī)電140.00
    ? ? TARGET02 緯軒機(jī)電160.00
    Power+ Target Module
    Power+ trip units are designed to accept an optional field-installable
    target module. The target module indicates long-time pickup, battery
    status, trip unit health status, and whether a breaker trip was
    caused by an overload, a short circuit or a ground fault. Target
    ?modules are available with or without ground fault indication.
    Power+ Trip Target Module
    Components: Parts
    1
    Prices and data subject Aftermarket Catalog www.geelectrical.com 1-21
    to change without notice
    Ratings Ratings Field Installable List Price Factory Installed List Price
    Vac Vdc Product Number GO-245B Product Number GO-245B
    120 – SPE120R 緯軒機(jī)電1671.00 SPE120 緯軒機(jī)電1838.00
    240 – SPE240R 緯軒機(jī)電1869.00 SPE240 緯軒機(jī)電2056.00
    – 24 SPE024R 緯軒機(jī)電1869.00 SPE024 緯軒機(jī)電2056.00
    – 48 SPE048R 緯軒機(jī)電1869.00 SPE048 緯軒機(jī)電2056.00
    – 72 SPE072R 緯軒機(jī)電1869.00 SPE072 緯軒機(jī)電2056.00
    – 125 SPE125R 緯軒機(jī)電1869.00 SPE125 緯軒機(jī)電2056.00
    Ratings Ratings Field Installable List Price Factory Installed List Price
    Vac Vdc Product Number GO-245B Product Number GO-245B
    120 – SPRCS120R 緯軒機(jī)電286.00 SPRCS120 緯軒機(jī)電315.00
    240 – SPRCS240R 緯軒機(jī)電286.00 SPRCS240 緯軒機(jī)電315.00
    – 24 SPRCS024R 緯軒機(jī)電286.00 SPRCS024 緯軒機(jī)電315.00
    – 48 SPRCS048R 緯軒機(jī)電286.00 SPRCS048 緯軒機(jī)電315.00
    – 72 SPRCS072R 緯軒機(jī)電286.00 SPRCS072 緯軒機(jī)電315.00
    – 125 SPRCS125R 緯軒機(jī)電286.00 SPRCS125 緯軒機(jī)電315.00
    Electrical Operator
    Remote Close Solenoid
    This accessory provides an electrically operated solenoid which, when energized, closes
    the breaker. It is suitable for control interlock schemes in which manual closing capability
    would not be convenient or desirable. The breaker is provided with a manual close
    button, which can be replaced by the Hidden "ON" Button accessory and/or sealed using
    the Limited Access Pushbutton Cover accessory. The remote close accessory is continuously
    rated and has an anti-pump feature, which prevents a motor operated breaker
    from repeatedly closing into a fault. Closing control voltage must be removed and re-applied
    for each breaker closure.
    Remote Close Solenoid
    Accessories—Stationary and Draw-out Breakers
    The complete line of Power Break? II breaker accessories may be either factory or field
    installed to meet user needs. The electronic shunt trip, the bell alarm, the bell alarm with
    mechanical lockout, and the undervoltage release modules are drop-in from the front of
    the breaker, interchangeable across all frames, and require no field internal wiring or
    breaker disassembly. Auxiliary switch modules are available in groups of 4, 8 or 12,
    NO/NC single-pole, double-throw (SPDT) switches. Their installation simply involves
    removal of breaker cover, installation of the switch module, routing of wiring and installation
    of the pre-wired terminal block and re-installation of the cover. Auxiliary switches
    are also interchangeable across all Power Break? II breaker frames.
    Electrical Operator
    The electrical operator mounts inside the front cover of the manually operated breaker.
    This accessory can be added to any Power Break? II breaker in the factory or the field
    to provide electrical spring charging and charge indication. For remote closing, the
    remote close solenoid must be priced and ordered separaby. All breakers are
    prewired to dedicated secondary terminals for easy field installation. When electrical
    operation is used, either a shunt trip or an undervoltage release must be ordered and
    priced separaby.
    Insulated Case Circuit Breakers
    Power Break? II Circuit Breaker Accessories
    Stationary and Draw-out Breaker Accessories
    All devices UL Listed for factory or field installation except where noted.
    Components: Parts
    1
    1-22 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Shunt Trip
    The shunt trip accessory is an electronic module, which provides remote control capability
    to open the circuit breaker. When activated, the shunt trip module sends a signal to
    the trip unit to open the breaker. This allows the trip unit to record, display, distinguish
    and communicate (in MicroVersaTrip? PM trip units) that the opening event was initiated
    by the shunt trip device. The shunt trip is continuously rated and requires no cut-off
    switch. When energized, the shunt trip supplies +24Vdc power to the trip unit to power
    the display.
    Ratings Ratings Field Installable List Price Factory Installed List Price
    Vac Vdc Product Number GO-245B Product Number GO-245B
    – 12 SPST012R 緯軒機(jī)電301.00 SPST012 緯軒機(jī)電328.00
    24 24 SPST024R 緯軒機(jī)電301.00 SPST024 緯軒機(jī)電328.00
    48 48 SPST048R 緯軒機(jī)電301.00 SPST048 緯軒機(jī)電328.00
    120 125 SPST120R 緯軒機(jī)電301.00 SPST120 緯軒機(jī)電328.00
    208 – SPST208R 緯軒機(jī)電301.00 SPST208 緯軒機(jī)電328.00
    240 250 SPST240R 緯軒機(jī)電301.00 SPST240 緯軒機(jī)電328.00
    480 – SPST480R1 緯軒機(jī)電301.00 SPST4801 緯軒機(jī)電328.00
    600 – SPST600R1 緯軒機(jī)電301.00 SPST6001 緯軒機(jī)電328.00
    1Kit contains externally mounted transber.
    Ratings Ratings Field Installable List Price Factory Installed List Price
    Vac Vdc Product Number GO-245B Product Number GO-245B
    12 SPSTL012R 緯軒機(jī)電401.00 SPSTL012 緯軒機(jī)電428.00
    24 24 SPSTL024R 緯軒機(jī)電401.00 SPSTL024 緯軒機(jī)電428.00
    48 48 SPSTL048R 緯軒機(jī)電401.00 SPSTL048 緯軒機(jī)電428.00
    120 125 SPSTL120R 緯軒機(jī)電401.00 SPSTL120 緯軒機(jī)電428.00
    208 – SPSTL208R 緯軒機(jī)電401.00 SPSTL208 緯軒機(jī)電428.00
    240 250 SPSTL240R 緯軒機(jī)電401.00 SPSTL240 緯軒機(jī)電428.00
    480 – SPSTL480R1 緯軒機(jī)電401.00 SPSTL480 緯軒機(jī)電428.00
    600 – SPSTL600R1 緯軒機(jī)電401.00 SPSTL600 緯軒機(jī)電428.00
    1Kit contains externally mounted transber.
    Shunt Trip Module
    Shunt Trip with Lockout Module
    The shunt trip with lockout is identical to the regular shunt trip, but when energized, it
    will also prevent closure of an "open" breaker by mechanically blocking both manual and
    electrical closing. When energized, the closing springs will not discharge, the movable
    contacts will not move; the contacts are "kiss free."
    Insulated Case Circuit Breakers
    Power Break? II Circuit Breaker Accessories
    Stationary and Draw-out Breaker Accessories
    All devices UL Listed for factory or field installation except where noted.
    Components: Parts
    1
    Prices and data subject Aftermarket Catalog www.geelectrical.com 1-23
    to change without notice
    Undervoltage Release Module
    The undervoltage release is an electronic module used to open the circuit breaker when
    the monitored voltage drops below 35-60% of its rated value. The undervoltage release
    "resets" when the monitored voltage is re-established allowing the circuit breaker to reclose
    (the sealing voltage of the UVR is 60-85% of its rated voltage).
    An undervoltage release trip operation is produced by the MicroVersaTrip? Plus unit in
    response to a signal from the undervoltage release module. This allows the trip unit to
    record, display, distinguish and communicate (in MicroVersaTrip? PM trip units) that the
    breaker opening event was due to undervoltage release. Operation of the undervoltage
    release module will prevent breaker contact closure, i.e. "kiss-free" operation. When
    energized, the undervoltage release supplies +24 Vdc power to the trip unit to power
    the display.
    Ratings Ratings Field Installable List Price Factory Installed List Price
    Vac Vdc Product Number GO-245B Product Number GO-245B
    24 – SPUV024ACR 緯軒機(jī)電301.00 SPUV024AC 緯軒機(jī)電328.00
    48 – SPUV048ACR 緯軒機(jī)電301.00 SPUV048AC 緯軒機(jī)電328.00
    120 – SPUV120ACR 緯軒機(jī)電301.00 SPUV120AC 緯軒機(jī)電328.00
    208 – SPUV208ACR 緯軒機(jī)電301.00 SPUV208AC 緯軒機(jī)電328.00
    240 – SPUV240ACR 緯軒機(jī)電301.00 SPUV240AC 緯軒機(jī)電328.00
    480 – SPUV480ACR1 緯軒機(jī)電301.00 SPUV480AC1 緯軒機(jī)電328.00
    600 – SPUV600ACR1 緯軒機(jī)電301.00 SPUV600AC1 緯軒機(jī)電328.00
    – 12 SPUV012DCR 緯軒機(jī)電301.00 SPUV012DC 緯軒機(jī)電328.00
    – 24 SPUV024DCR 緯軒機(jī)電301.00 SPUV024DC 緯軒機(jī)電328.00
    – 48 SPUV048DCR 緯軒機(jī)電301.00 SPUV048DC 緯軒機(jī)電328.00
    – 125 SPUV125DCR 緯軒機(jī)電301.00 SPUV125DC 緯軒機(jī)電328.00
    – 250 SPUV250DCR 緯軒機(jī)電301.00 SPUV250DC 緯軒機(jī)電328.00
    1Kit contains externally mounted transber.
    Undervoltage Release Module
    Bell Alarm (Alarm Only)
    The bell alarm module is used to signal breaker "tripped" status to other accessories
    (e.g., external alarm devices, indicating lights, relays, or logic circuits) for remote indication
    and interlocking functions. The bell alarm response is configurable by means of
    rear-mounted DIP switches on the trip unit. The bell alarm can be made to operate in
    response to an overcurrent (including ground fault) or protective relay trip and/or a
    shunt trip operation, and/or operation of the undervoltage release module. It is not
    actuated as a result of normal breaker "ON/OFF" operation.
    This module provides a visual, mechanical pop-out target, which protrudes through the
    face of the circuit breaker door when it operates. The bell alarm may be reset manually
    by depressing the mechanical target, or automatically by closing the breaker.
    The bell alarm is provided with one SPDT switch with control power duty contacts as
    shown in the auxiliary switch accessories.
    Ratings Ratings Field Installable List Price Factory Installed List Price
    Vac Vdc Product Number GO-245B Product Number GO-245B
    240 125-250 SPBAA240R 緯軒機(jī)電124.00 SPBAA240 緯軒機(jī)電135.00
    600 125-250 SPBAA600R1 緯軒機(jī)電124.00 SPBAA6002 緯軒機(jī)電135.00
    2600 Vac module not UL Listed.
    Bell (Alarm Only)
    List Price
    Debion Product Number GO-245B
    Time Delay Module
    (0.1 to 1.0 second delay) SPUVTD 緯軒機(jī)電430.00
    Time Delay Module for UVR
    The time delay module prevents nuisance tripping due to momentary loss of voltage.
    The module has 120 Vac b and 125 Vdc output and must be used with the 125 Vdc UVR.
    Insulated Case Circuit Breakers
    Power Break? II Circuit Breaker Accessories
    Stationary and Draw-out Breaker Accessories
    All devices UL Listed for factory or field installation except where noted.
    Components: Parts
    1
    1-24 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Bell Alarm With Lockout
    The bell alarm with lockout module combines both the bell alarm and a manual lockout
    function. The bell alarm switch operates identically to the standard bell alarm module,
    except that the mechanical pop-out target must be manually reset before the breaker
    can be closed.
    Operation of the bell alarm with lockout module can be independently set by means
    of setting the DIP switches at the rear of the trip unit. Current rating of the single SPDT
    switch is identical to the auxiliary switch accessories.
    Ratings Ratings Field Installable List Price Factory Installed List Price
    Vac Vdc Product Number GO-245B Product Number GO-245B
    240 125-250 SPBAL240R 緯軒機(jī)電124.00 SPBAL240 緯軒機(jī)電135.00
    600 125-250 SPBAL600R1 緯軒機(jī)電124.00 SPBAL6001 緯軒機(jī)電135.00
    1600 Vac module not UL Listed. Bell Alarm with Mechanical Reset Lockout
    Auxiliary Switch
    An auxiliary switch signals the circuit breaker’s primary contact b (i.e., OPEN or
    CLOSED) to other devices, such as indicating lights, relays or logic circuits. This enables
    the user to provide remote indication, interlocking or control operations as a function of
    breaker primary contact b. The auxiliary switch operation is independent of the
    b by which the breaker is opened or closed. The auxiliary switch does not distinguish
    between a "tripped" or "open" condition. The auxiliary switch contacts follow the
    main breaker contacts on opening and precede them on closing.
    Auxiliary switch modules are available with 4, 8 or 12 NO/NC (SPDT) switches for control
    power duty ac/dc ratings. When ordered for field installation, an auxiliary switch module
    comes pre-wired to its own terminal board, which mounts with one screw to the left of
    the breaker. A special accessory, available for draw out breakers, comes pre-wired to the
    ?breaker secondary disconnect. All switch ratings are 6A at 120V-600 Vac, 1/2A at 125
    Vdc and 1/4A at 250 Vdc.
    Auxiliary Switches for Stationary Breakers
    No. of SPDT
    Ratings Ratings Switch Elements Field Installable List Price Factory Installed List Price
    Vac Vdc (Contacts) Product Number GO-245B Product Number GO-245B
    240 125-250 4 SPAS240AB4R 緯軒機(jī)電268.00 SPAS240AB4 緯軒機(jī)電293.00
    240 125-250 8 SPAS240AB8R 緯軒機(jī)電564.00 SPAS240AB8 緯軒機(jī)電616.00
    240 125-250 12 SPAS240AB12R 緯軒機(jī)電651.00 SPAS240AB12 緯軒機(jī)電710.00
    600 125-250 4 SPAS600AB4R1 緯軒機(jī)電268.00 SPAS600AB41 緯軒機(jī)電293.00
    600 125-250 8 SPAS600AB8R1 緯軒機(jī)電564.00 SPAS600AB81 緯軒機(jī)電616.00
    1600 Vac module not UL Listed.
    Auxiliary Switch with
    Pre-wired Secondary Terminals
    for Stationary Breaker
    Auxiliary Switch with
    Pre-wired Secondary Terminals
    for Draw-out Breaker
    Auxiliary Switches for Draw-out Breakers
    No. of SPDT
    Ratings Ratings Switch Elements Field Installable List Price Factory Installed List Price
    Vac Vdc (Contacts) Product Number GO-245B Product Number GO-245B
    240 125-250 4 SPAS240AB4DR 緯軒機(jī)電551.00 SPAS240AB4D 緯軒機(jī)電576.00
    240 125-250 8 SPAS240AB8DR 緯軒機(jī)電847.00 SPAS240AB8D 緯軒機(jī)電899.00
    240 125-250 12 SPAS240AB12DR 緯軒機(jī)電934.00 SPAS240AB12D 緯軒機(jī)電993.00
    600 125-250 4 SPAS600AB4DR1 緯軒機(jī)電551.00 SPAS600AB4D1 緯軒機(jī)電576.00
    600 125-250 8 SPAS600AB8DR1 緯軒機(jī)電847.00 SPAS600AB8D1 緯軒機(jī)電899.00
    1600 Vac module not UL Listed.
    Insulated Case Circuit Breakers
    Power Break? II Circuit Breaker Accessories
    Stationary and Draw-out Breaker Accessories
    All devices UL Listed for factory or field installation except where noted.
    Components: Parts
    1
    Prices and data subject Aftermarket Catalog www.geelectrical.com 1-25
    to change without notice
    Mechanical Operations Counter
    The mechanical operations counter is mounted behind the front cover of the breaker. It
    is viewable through a rectangular knockout b opening in the breaker cover. It is a
    five-digit, non-resettable counter, which is actuated each time the breaker is opened by
    any means.
    Field Installed List Price Factory Installed List Price
    Product Number GO-245B Product Number GO-245B
    SPCOUNTERR 緯軒機(jī)電100.00 SPCOUNTER 緯軒機(jī)電125.00
    Hidden "ON" Button
    The hidden "ON" button is assembled to the mechanism behind an unlabeled, false
    ?pushbutton. Manual closing of the breaker can only be perbed by means of a small
    ?diameter rod. This accessory is used to limit access to the manual "ON" control to
    authorized personnel.
    Field Installed List Price Factory Installed List Price
    Product Number GO-245B Product Number GO-245B
    SPPBNONR 緯軒機(jī)電64.00 SPPBNON 緯軒機(jī)電64.00
    Maintenance/Repair Parts
    Debion Product Number List Price GO Schedule
    Top Cover and Rating Labels SPBII-REPLACE_COVER1 緯軒機(jī)電600.00 148C
    Replacement MVT Door 10054335P1 緯軒機(jī)電20.00 148G
    Replacement Powerplus Door 10054335P2 緯軒機(jī)電16.00 148G
    Stop Block Kit w/Installation Tool SPBUMPERKIT 緯軒機(jī)電175.00 148C
    Stop Block Kit (no tools) SPBUMPNTKIT 緯軒機(jī)電90.00 148C
    1Special handling and order entry required to preserve UL Listing of breaker.
    Contact Post Sale Service for additional details of special process.
    Limited Access Pushbutton Cover
    This accessory limits access to "ON/OFF" control of a breaker to authorized personnel.
    The pushbutton cover accessory consists of transparent hinged covers that can be individually
    sealed to the limited access assembly. Both the "ON" and "OFF" buttons can be
    pilot drilled to allow use of a 1/8" rod to operate either one or both pushbuttons.
    Field Installed List Price Factory Installed List Price
    Product Number GO-245B Product Number GO-245B
    SPPBCOVERR 緯軒機(jī)電80.00 SPPBCOVER 緯軒機(jī)電90.00
    Mechanical Operations Counter
    Breaker with limited access pushbutton
    cover assembly installed
    Activating the breaker closing
    mechanism through the hole in the
    Hidden “ON” Button
    Insulated Case Circuit Breakers
    Power Break? II Circuit Breaker Accessories
    Stationary and Draw-out Breaker Accessories
    All devices UL Listed for factory or field installation except where noted.
    Components: Parts
    1
    1-26 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Key Interlock Provisions
    The key interlock provision enables the user to mount a one- to four-cylinder, narrowfaced,
    Kirk-type FN or Superior customer-supplied lock on the face of the breaker. This
    accessory provides mounting for key interlocks that are furnished by the customer. The
    key interlock provision works in conjunction with the padlock provision. The key interlock
    extends a lever through the padlock hasp when the key is turned to the key removal or
    bolt extended b. Additionally, the accessory provides a hasp for mounting three
    padlocks with 1/4" to 3/8" diameter shanks.
    Padlock Provisions (Standard)
    Padlocking provisions are standard on all Power Break? II circuit breakers. When the
    breaker is in the open b, and the padlock hasp is raised at least 1/4", the breaker
    ?cannot be closed mechanically or electrically. The hasp accepts up to three padlocks
    with 1/4" to 3/8" diameter shanks.
    Walking Beam Interlocks—Stationary Breakers Only
    Walking beam interlocks are mechanical devices used to prevent two adjacent circuit
    breakers from both being in the "ON" or closed b at the same time. However, both
    breakers can be in the "OFF" or open b.
    Door Interlock
    The door interlock provides interlocking of the circuit breaker compartment’s hinged
    door so that the breaker must be in the "OFF" b before the door can be opened.
    The door interlock is defeatable with a small tool to allow authorized access.
    Circuit Breaker List Price
    Envelope Size (Amperes) Product Number GO-245B
    800, 1600 and 2000 SPWB20 緯軒機(jī)電1228.00
    3000 SPWB30 緯軒機(jī)電1228.00
    4000 SPWB40 緯軒機(jī)電1228.00
    Product Numbers, Key Interlock Provisions
    Circuit Breaker Number of Field Installed List Price Factory Installed List Price
    Envelope Size (Amps) Key Locks Product Number GO-245B Product Number GO-245B
    All 1 to 4 SPK4R 緯軒機(jī)電355.00 SPK4 緯軒機(jī)電426.00
    Field Installed List Price Factory Installed List Price
    Product Number GO-245B Product Number GO-245B
    SPDILR 緯軒機(jī)電173.00 SPDIL 緯軒機(jī)電208.00
    Key Interlock Kit (lock not included)
    Door Interlock
    Insulated Case Circuit Breakers
    Power Break? II Circuit Breaker Accessories
    Stationary and Draw-out Breaker Accessories
    All devices UL Listed for factory or field installation except where noted.
    Components: Parts
    1
    Prices and data subject Aftermarket Catalog www.geelectrical.com 1-27
    to change without notice
    Lug Adapter Kits
    Kits pre-mount to bus structure allowing cabling or bussing to be completed prior to
    breaker mounting. Accepts either lugs or crimp-type connector terminals. Kit includes
    adapter and hardware for either a three-pole line-side, or a three-pole load-side connection.
    (Lugs not included).
    Circuit Breaker Max Rating Product Lug Max. Cables Wire Range List Price
    Envelope Size (Amperes) (Amperes) Number Per Kit Per Pole kcmil Cu/AI GO-245B
    400 TPLUG106 1 1 (2) #2 2-600 緯軒機(jī)電18.50
    600 TPLUG206 1 2 (2) #2 2-600 緯軒機(jī)電27.50 800 800 TPLUG308 1 3 (3) 300-750 緯軒機(jī)電32.00
    800 TPLUG1084 1 3 3/0-800 緯軒機(jī)電23.00
    1600 800 TPLUG1084 1 6 3/0-800 緯軒機(jī)電23.00
    1600 TPLUG408 1 4 500-800 緯軒機(jī)電39.00
    2000 TPLUG1084 1 6 3/0-800 緯軒機(jī)電23.00
    2000 800 TSLUG08 9 3 3/0-800 緯軒機(jī)電274.00
    1200 TSLUG12 12 4 3/0-800 緯軒機(jī)電296.00
    1600 TSLUG16 15 5 3/0-800 緯軒機(jī)電345.00
    2000 TSLUG20 18 6 3/0-800 緯軒機(jī)電383.00
    3000 2500 TSLUG25 21 7 3/0-800 緯軒機(jī)電418.00
    3000 TSLUG30 27 9 3/0-800 緯軒機(jī)電630.00
    4000 4000 TSLUG40 27 9 3/0-800 緯軒機(jī)電1045.00
    4For use with adapter kit only. See table above.
    Frame Product Suitable for List Price
    Rating (Amperes) Number use with up to: GO-245B
    3 TPLUG108 Lugs or
    800 TPLUGA08 3 crimp Lugs1 per pole 緯軒機(jī)電78.50
    6 TPLUG108 lugs or
    1600 TPLUGA162 6 crimp Lugs1 per pole 緯軒機(jī)電389.00
    6 TPLUG108 Lugs or
    2000 SPLUGA203 6 crimp Lugs1 per pole 緯軒機(jī)電487.00
    1Anderson No. VCEL-075-12H1 or equivalent
    2T-Studs - TP16FCA - included with adapter
    3T-Studs - SP20FCA - included with adapter
    Lug Kits
    Kits accept Cu/AI wire and are suitable for direct mounting to the breaker. When ordering
    Type TPLUG kits, order one kit per line or load pole. Example: A complete set of lugs
    for the line side of an 800A frame, 400A trip breaker would be Qty 3-TPLUG106 lugs.
    When ordering TSLUG kits order one kit per line or load side; TSLUG kits require use of
    T-studs. Example: A complete set of lugs for a 3000A frame, 2500A trip breaker would be
    Qty 1-TSLUG25. T-Studs would also be required.
    2000 Ampere Power Break? II breaker with
    SPLUGA20 lug adapter kit and 18 lugs
    (TPLUG108)
    Type TPLUG206
    Type TPLUG408
    Type TPLUG308
    Type TSLUG20
    Insulated Case Circuit Breakers
    Power Break? II Circuit Breaker Accessories
    Stationary Breaker Mounting Kits
    All devices UL Listed for factory or field installation except where noted.
    Components: Parts
    1
    1-28 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    T-Studs
    T-studs mount directly to the breaker, and can be rotated for either vertical or horizontal
    bus connection. 4000 ampere T-studs are for vertical bus bars only. Product number
    includes one stud. Both copper and aluminum T-studs are tin-plated.
    Trimplate
    Factory Installed Field Installable List Price
    Product Number Product Number GO-245B
    SPTRIMPLATE SPTRIMPLATER 緯軒機(jī)電64.00
    T-Studs—Front Connected Breaker
    Circuit Breaker Max. Rating List Price
    Frame Size (Amperes) (Amperes) Product Number GO-245B
    800 800 SP08FCA1 緯軒機(jī)電36.00
    800 800 SP08FCC2 緯軒機(jī)電36.00
    2000 800-2000 SP20FCA1 緯軒機(jī)電49.00
    2000 800-2000 SP20FCC2 緯軒機(jī)電49.00
    2500 2000 SPS20FCA1 緯軒機(jī)電48.75
    2500 2500 SPS25FCC2 緯軒機(jī)電51.50
    3000 3000 SPS30FCC2 緯軒機(jī)電181.50
    4000 4000 SPS40FCC2 緯軒機(jī)電240.50
    4000 4000 SPS40LFCC2,3 緯軒機(jī)電395.00
    T-Studs—Back Connected Breaker
    Circuit Breaker Max. Rating List Price
    Frame Size (Amperes) (Amperes) Product Number GO-245B
    2500 2000 SPS20BCA1,4 緯軒機(jī)電48.75
    2500 2500 SPS25BCC2,4 緯軒機(jī)電51.50
    3000 3000 2,5 緯軒機(jī)電181.50
    1Aluminum
    2Copper
    3Extra long stud. Alternate with SPS40FCC for ease of installation.
    4Six T-studs at no charge when ordered with breaker
    5Supplied with integral T-stud
    2000A Breaker with "T" Studs Mounted
    Insulated Case Circuit Breakers
    Power Break? II Circuit Breaker Accessories
    Stationary Breaker Mounting Kits, Wall Mounted Enclosures, Floor Mounted Enclosures
    All devices UL Listed for factory or field installation except where noted.
    Components: Parts
    1
    Prices and data subject Aftermarket Catalog www.geelectrical.com 1-29
    to change without notice
    MicroVersaTrip? Portable Test Kit
    The test kit product number TVRMS2 is a portable, battery-powered,
    test kit which provides for trip unit health checks and functional
    trip and no-trip tests. It also provides defeat of the
    ground-fault function and can be used in conjunction with highcurrent
    test equipment. The test kit can be used to provide +24V
    power to the trip unit for cold set-up and viewing of trip targets.
    This test kit is for use with RMS-9, Epic, MicroVersaTrip? Plus and
    MicroVersaTrip? PM trip units. The kit uses six rechargeable ni-cad
    or standard alkaline "D" cells supplied by the customer. Kit can
    also be powered by 120 Vac source.
    List Price
    Debion Product Number GO-245B
    Portable Test Kit TVRMS2 緯軒機(jī)電3000.00
    MicroVersaTrip? Portable Power Pack
    The handheld MicroVersaTrip? portable battery pack provides
    an independent power source for Enhanced MicroVersaTrip? Plus
    and MicroVersaTrip? PM trip units as an alternative to the TVRMS2
    test set. The power pack is used to power up the trip unit to set or
    adjust trip set points when the breaker is on the bench or otherwise
    not powered up. It connects to the trip unit through
    the rating plug test jack. It requires three (3) standard 9 Vdc
    alkaline batteries (not included).
    List Price
    Debion Product Number GO-245B
    MicroVersaTrip? Plus and PM
    Portable Power Pack TVPBP 緯軒機(jī)電75.00
    POWER LEADER? Power Supplies
    Power supply for furnishing 24Vdc control power for
    MicroVersaTrip? Plus and PM trip units.
    System Requirements Product List Price
    Debion (price separaby) Number G0-104A
    1.5 ampere power supply
    Price one PLPS4G01 for
    each line-up. 45 trip units Input power, 100VA
    and 100 ft. maximum. (85-265Vac or 100-370Vdc) PLPS4G01 緯軒機(jī)電1250.00
    POWER LEADER? Voltage Conditioner
    Conditions and scales 120Vac to 1.76 Vac for use by the trip unit
    for voltage sensing. Provides transient protection. Voltage conditioners
    require isolation PTs.
    System Requirements Product List Price
    Debion (price separaby) Number G0-104A
    Supplies isolated bus
    voltage signal to One set of 3 voltage conditioners
    MicroVersaTrip? PM required for each voltage sensing 緯軒機(jī)電200.00
    trip units. b. PTs also required. PLVC1G01 per set
    Neutral Current Sensors1
    Circuit Breaker Neutral Sensor
    Breaker Frame Sensor Rating Rating or Tap Product List Price
    (Amperes) (Amperes) Settings (Amperes) Number GO-245B
    200 200 TSVG302 緯軒機(jī)電266.00
    800 400 400/200 TSVG304A 緯軒機(jī)電266.00
    400 600/3002 TSVG306A 緯軒機(jī)電266.00
    800-1600 800 800/400 TSVG308A 緯軒機(jī)電266.00
    1000 800/4002 TSVG808A 緯軒機(jī)電266.00
    1600 1000 1000/500 TSVG810A 緯軒機(jī)電266.00
    1600 1200/6002 TSVG812A 緯軒機(jī)電266.00
    1600 1600/1000 TSVG816A 緯軒機(jī)電266.00
    2000 2000 2000/1000 TSVG820A 緯軒機(jī)電266.00
    1000 800/4002 TSVG808A 緯軒機(jī)電266.00
    1000 1000/500 TSVG810A 緯軒機(jī)電266.00
    1000 1200/6002 TSVG812A 緯軒機(jī)電266.00
    3000 1000 1600/10002 TSVG816A 緯軒機(jī)電266.00
    2000 2000/1200 TSVG820A 緯軒機(jī)電266.00
    2500 2500/1800 TSVG825A 緯軒機(jī)電266.00
    3000 3000/2400 TSVG830A 緯軒機(jī)電266.00
    4000 4000 4000/3000 TSVG940A 緯軒機(jī)電266.00
    1Match neutral current sensor rating (or tap setting) to circuit breaker sensor rating.
    2For use with multiple source ground fault protection schemes. Rating does not
    match MicroVersaTrip? Plus or PM frame sensor.
    Neutral Current Sensor
    Rating Plug Removal Tool
    List Price
    Product Number GO-135S
    TRTOOL 緯軒機(jī)電12.00
    Reference
    Instructions GEH-6492
    Reference
    Instructions GEH-5946
    Insulated Case Circuit Breakers
    Power Break? II Circuit Breaker Accessories
    Neutral Current Sensors and POWER LEADER Accessories
    Components: Parts
    1
    1-30 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Features
    —Draw-outs through 4000 amperes are UL Listed, 100% rated
    —Modular design for simplified installation—6 basic sizes—800, 1600, 2000, 2500,
    3000, 4000—5 inch pole centers
    —Screw racking mechanism provides positive racking motion
    —Self aligning primary and secondary disconnects
    —Four b draw-out—engaged, test, disengaged, fully withdrawn—
    simplifies system testing and inspection
    —Breaker b indicator bly shows breaker b
    —Provisions for padlocking breaker in test or disengaged b
    —Mechanical interlock logic prevents movement of a closed breaker
    —Suitable for reverse feeding
    Debion
    The draw-out assembly consists of a substructure housing unit designed as a compact
    self-supporting unit and a draw-out breaker which must be ordered separaby. The
    substructure contains mounting holes, self-supporting male plugs and extendable rails,
    and can be ordered separaby for installation in your switchboard or enclosure.
    The Power Break? II draw-out breaker is a self-contained, heavy-duty assembly designed
    to offer simplified breaker inspection without de-energizing the main bus structure.
    The draw-out breaker comes complete with racking mechanism drive, wheels, primary
    and secondary disconnects and cooperating interlock systems.
    Accessories such as dead-front shutters, by-pass switches (b switches), and
    padlock devices are available and field installable.
    OEM Substructures
    Substructures are available for both standard and Hi-Break Power Break? II breakers.
    Holes are provided for bolting on a shelf or supports. Holes are also provided in the primary
    stabs for bolting to busbars or terminal lugs. Substructure secondary disconnects
    are ordered and priced separaby. Order Hi-Break substructures for use with Power
    Break? II switches.
    Frame Rating Standard Break List Price Hi-Break List Price
    (Amperes) Product Number GO-245B Product Number GO-245B
    800 SPSDOS08 緯軒機(jī)電671.00 SPHDOS08 緯軒機(jī)電724.00
    1600 SPSDOS16 緯軒機(jī)電1300.00 SPHDOS16 緯軒機(jī)電1403.00
    2000 SPSDOS20 緯軒機(jī)電1892.00 SPHDOS20 緯軒機(jī)電2040.00
    2500 SPSDOS25 緯軒機(jī)電2048.00 SPHDOS25 緯軒機(jī)電2207.00
    3000 SPSDOS30 緯軒機(jī)電2739.00 SPHDOS30 緯軒機(jī)電2951.00
    4000 SPSDOS40 緯軒機(jī)電6916.00 SPHDOS40 緯軒機(jī)電7455.00
    List Price
    Location Product Number GO-245B
    Substructure SPDOSD36S 緯軒機(jī)電283.00
    Breaker1 SPDOSD36B 緯軒機(jī)電283.00
    1Order for replacement only. Included and factory wired with draw-out breaker.
    Draw-out Breaker in Substructure
    1600-ampere substructure for
    standard break breaker
    Secondary Disconnect for Draw-out Breakers
    Control wiring is connected through draw-out secondary disconnects in the "TEST" and
    ?"CONNECTED" bs only. Up to 72 control circuits are possible through 36 b
    plug-style secondary disconnect blocks factory mounted to each side of draw-out
    breakers. One substructure disconnect (SPDOSD36S) must be ordered for each breaker
    when accessories or communications are used. When auxiliary switches are used along
    with any other electrical accessory or communications, two disconnects must be ordered.
    Insulated Case Circuit Breakers
    Power Break? II Circuit Breaker Accessories
    Draw-out Breaker Accessories
    Components: Parts
    1
    Prices and data subject Aftermarket Catalog www.geelectrical.com 1-31
    to change without notice
    Racking Tool
    The racking tool is a drive wrench with a square 1/2" socket
    that engages the racking mechanism of the draw-out breaker.
    One racking tool is supplied with every five draw-out breakers
    at no charge.
    List Price
    Frame Rating Product Number GO-245B
    All TDORT 緯軒機(jī)電70.00
    Mechanical Interlocks
    Mechanical interlocks provide the same function as the walking
    beam accessory for stationary breakers, except they are used
    with two draw-out breakers: mounted on common compartment
    centerline, in either the same vertical section or adjacent vertical
    sections.
    List Price
    Envelope Size Product Number GO-245B
    800-2000 SPDOWB20 緯軒機(jī)電1310.00
    2500-4000 SPDOWB40 緯軒機(jī)電1310.00
    Rail Kit
    This field installable rail kit may be used to shorten the two
    standard OEM substructure rails by 3-1/2 inches.
    List Price
    Product Number GO-245B
    SPRAILS 緯軒機(jī)電310.00
    Position Switch
    Provides positive indication when the draw-out breaker or switch
    primary contact fingers have been fully withdrawn from the main
    bus connections. Switch contacts change state only after the
    primary fingers are fully disconnected when the breaker is being
    moved from the CONNECTED b through the TEST b
    and into the DISCONNECTED b.
    May be used as part of a safety interlocking system in addition
    to the visual indicator on the draw-out substructure. The Position
    Switch accessory does not indicate either the TEST or CONNECTED
    b. The switch assembly mounts on the stationary frame
    and the actuator mounts to the carriage. Switch contacts are
    rated at 10A at 600 Vac, 0.75A at 125 Vdc, and 0.25A at 250 Vdc.
    Number of List Price
    Switch Elements Product Number GO-245B
    2 NO/2 NC SDOPS2L 緯軒機(jī)電177.00
    4 NO/4 NC SDOPS4L 緯軒機(jī)電256.00
    6 NO/6 NC SDOPS6L 緯軒機(jī)電336.00
    Shutter Kit
    This field installable kit provides shutters used to prevent unintentional
    contact with potentially live primary disconnect stabs when
    a breaker is racked out of an energized switchboard compartment.
    List Price
    Frame Rating Product Number GO-245B
    800-2000A SPDSS20 緯軒機(jī)電501.00
    3000A SPDSS30 緯軒機(jī)電501.00
    4000A SPDSS40 緯軒機(jī)電501.00
    By-Pass Switch
    Provides positive indication that the draw-out breaker or switch
    ?primary contact fingers are fully connected to the main bus in the
    substructure. Switch contacts change states only after the primary
    fingers are fully connected when the breaker is being
    moved from the DISCONNECTED b through the TEST b
    and into the CONNECTED b.
    May be used to provide control circuit continuity or downstream
    ?signaling that the draw-out breaker is connected in addition to
    the visual b indicator on the draw-out substructure. The
    By-pass switch accessory does not indicate either the TEST or
    DISCONNECTED b. The switch assembly mounts on the stationary
    frame and the actuator mounts to the carriage. Switch
    contacts are rated at 10A at 600 Vac, 0.75A at 125 Vdc, and
    0.25A at 250 Vdc.
    Number of List Price
    Switch Elements Product Number GO-245B
    2 NO/2 NC TDOBP2L 緯軒機(jī)電177.00
    4 NO/4 NC TDOBP4L 緯軒機(jī)電256.00
    6 NO/6 NC TDOBP6L 緯軒機(jī)電336.00
    Racking Padlock Provision
    The racking padlock provides a means for the user to prevent racking
    tool engagement, thereby preventing movement of the breaker
    between the DISCONNECTED, TEST and CONNECTED bs.
    List Price
    Frame Rating Product Number GO-245B
    All TDOPC 緯軒機(jī)電46.00
    Lifting Bar
    The lifting bar provides a means of safely lifting a draw-out circuit
    breaker. A chain hook can be attached to the central hole in the
    lifting bar or a 1" diameter black iron pipe can be put through the
    two holes above the hooks, allowing two people to carry the
    breaker below waist level from either side of the breaker.
    One lifting bar is supplied with every five draw-out breakers at
    no charge.
    List Price
    Frame Rating Product Number GO-245B
    All TDOLB 緯軒機(jī)電104.00
    Insulated Case Circuit Breakers
    Power Break? II Circuit Breaker Accessories
    Draw-out Breakers and Accessories
    All devices UL Listed for factory or field installation except where noted.
    Components: Parts
    1
    1-32 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Neutral Current (800: 1 ratio) Sensors
    Inside Core Thermal Rating Weight Product List Price
    Dimensions Construction (Amperes) (Lbs.) Number GO-142
    2.5” Dia. Solid 1600 3 TGS0002 緯軒機(jī)電460.00
    5” Dia. Solid 2500 4 TGS0005 緯軒機(jī)電731.00
    8” Dia. Solid 3000 7 TGS0008 緯軒機(jī)電856.00
    4” x 8” Split 4000 15 TGS0408 緯軒機(jī)電1439.00
    8” x 8” Split 4000 25 TGS0808 緯軒機(jī)電1482.00
    Neutral Current Sensor - Solid
    Neutral Current Sensor - Split
    Disconnect Switches and Operating Mechanisms
    High-Pressure Contact Switch
    With Integral Ground Fault Devices, 800-4000 Amperes, 600 Vac Max., UL File. No. E-51827
    Components: Parts
    1
    Prices and data subject Aftermarket Catalog www.geelectrical.com 1-33
    to change without notice
    Field Installed Lugs Kits 800-1600 Ampere
    Switches–Direct Mounting
    Field installed only. Kits consist of lugs and hardware for direct
    ?mounting to switch terminal straps (multiple-hole tang lugs) or lugs
    for mounting to 800 ampere terminal adapter kit. Order three kits
    for three-pole line or load end. For 1600-ampere, copper conductors
    must be used.
    Ampere Rating Accessory Wire Range Product List Price
    Type Cu/Al Number GO-145A
    800A Lug Kit Line (3) 300-750 THPCLUG308 緯軒機(jī)電63.50 & Lug Kit Load
    1200A, 1600A Lug Kit Line (4) 500-800 kcmil TPLUG408 緯軒機(jī)電39.001
    1200A, 1600A Lug Kit Load (4) 500-800 kcmil THPCLUG408 緯軒機(jī)電77.50
    1GO-245B
    Field Installed Lugs Kits 2000-4000 Ampere
    Switches–Direct Mounting
    Field installed only. To terminate line and load cables, must be
    used in conjunction with bus-connection adapter on page 7-20 (T
    Studs). Each lug kit includes lugs, straps and hardware for threephase
    line or load connections. Each cable lug accommodates
    1–3/0 Cu or 250 kcmil Al to 800 kcmil Cu-Al. Accepts Anderson
    VersaCrimp when lugs are removed from straps.
    No. of Lugs per Pole Product List Price
    Ampere Rating Line or Load End Number GO-245B
    2000A 6 TSLUG20 緯軒機(jī)電383.00
    2500A 7 TSLUG25 緯軒機(jī)電418.00
    3000A 9 TSLUG30 緯軒機(jī)電630.00
    4000A 11 TSLUG40 緯軒機(jī)電1045.00
    Field Installed T Studs
    Field installed only. May be used to adapt line and load terminals
    of switch to vertical or horizontal bus arrangements. Three
    required for line or load connections on three-phase bus. Accepts
    either lugs, bolts, or Anderson VCEL VersaCrimp.
    Basic Switch Product List Price
    Rating (Amperes) Number GO-145A
    800 THPC08FCA2 緯軒機(jī)電71.00
    1200-1600 TP16FCA 緯軒機(jī)電113.00
    2000 TS20FCA 緯軒機(jī)電113.00
    2500 TS25FCA 緯軒機(jī)電119.00
    3000 TS30FCA 緯軒機(jī)電418.00
    4000 (5)TS40FCA 緯軒機(jī)電562.00
    4000 (1)TS40LFCA3 緯軒機(jī)電789.00
    2For vertical bussing only.
    3For center pole, line terminal.
    Disconnect Switches and Operating Mechanisms
    High-Pressure Contact Switch
    Accessories, UL Listed
    Section 2: Switchgear
    Table of Contents
    Switchgear
    2
    Prices and data subject Aftermarket Catalog www.geelectrical.com 2-1
    to change without notice
    History/Timeline .............................................................................2-2
    Low Voltage Power and DC Circuit Breakers .............................2-3
    Gerapid High Speed DC Circuit Breakers ..........................................2-3
    AK and AKR Low Voltage Power
    Circuit Breakers.........................................................................................2-4
    Trip Unit Conversion Kits...........................................................................2-5
    Overview – EnbliGuard? TU and ProTrip?
    Conversion Kits.....................................................................................2-5
    ProTrip? Trip Unit Conversion Kits Selection Guide ...............2-7
    ProTrip? Rating Plugs.........................................................................2-11
    EnbliGuard? TU Trip Unit Conversion
    Kits Selection Guide.........................................................................2-12
    EnbliGuard? TU Trip Rating Plugs................................................2-16
    EnbliGuard? TU Trip Unit Conversion Kit
    Accessories and Hardware..........................................................2-17
    Trip Unit Conversion Kit Accessories ...........................................2-18
    Electrically Operated Racking Device .............................................2-20
    Technical Specifications.....................................................................2-21
    Reference Publications............................................................................2-22
    Asbestos Free Arc Quencher Replacement Kits..........................2-23
    This catalog contains replacement parts, retrofits, accessories,
    and older generation products. For current generation products,
    please see the GE BuyLog? or Control Catalog.
    Switchgear
    2-2 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    Low Voltage Switchgear History/Timeline
    GE Low Voltage Switchgear History/Timeline
    1930’s-50 AE/AL Manufactured from 1930’s(?) to the early 1950’s
    1951-75 AKD
    AK = Power Circuit Breaker Equipment
    D = Drawout circuit breaker construction
    Manufactured 1951 - 1975, all bolted copper bus design, all breakers drawout, AK-1, 2, 3 - 15 / 25 / 50 / 75 / 100.
    4000A max bus rating, 4 levels of bus, ring bus used in all feeder sections, main bus has provisions for future extension,
    sections in outdoor construction did not line up in the front, indoor construction has extended frames to allow
    the fronts of the sections to align. Indoor depths 49” (225 / 600A breakers), 59” (1600A breakers), 63” (3200 / 4000A
    breakers). Breakers had ratcheting drawout mechanism – open door drawout. Painted ANSI 61 light gray, manufactured
    in Philadelphia 1951 - mid-60’s, Bbington mid-60’s - 1975. Breaker compartment was a welded assembly,
    equipment frame was bolted. Breaker boxes were stacked to make a vertical section with equipment frame around
    the breaker boxes. No bus compartment barriers, open bus design. Ring silver plating on bolted connections.
    1951-60’s AKS Stationary version of AKD, manufactured 1951 - 60’s
    1960-77 AKD-5 Manufactured 1960 - 1977, aluminum bus with “flash-butt welded” copper to aluminum at bolted connections.
    AK-2A, 3A -25 / 50 / T50 / 75 / 100 (“A” signifies AKD-5 drawout). Pull-lanyard drawout mechanism on early
    design, replaced by single jackscrew mechanism and then replaced by double jack-screw mechanism. Closed-door
    drawout with inner house breaker compartment. 60” deep frame with 18” extension option. Outdoor protected
    aisle uses 60” deep indoor frame. Two bus levels available, ring bus used at 4000A. Welded / riveted frame, bus
    compartment barriers, line/load separation barriers on mains and ties, isolation barriers on transber transitions,
    copper runbacks on feeder breakers, ring silver plating on copper, aluminum bus unplated (welded connections).
    Painted sand gray (beige), some instrument doors painted blue. AKR-30/50 in 22” wide sections introduced
    in AKD-5 construction in early -70’s.
    1977-81 AKD-6 Manufactured in Salisbury, NC 1977 - 1981. Some AKD-5 construction built in Salisbury ’75 - ’77 and nameplated
    as AKD-6. No flash-butt welded aluminum to copper. Aluminum bus is tin plated and bolted at shipping splits (welded
    everywhere else). Copper bus design has ring silver plating at bolted joints. Introduced AKR-75 / 100. Stab-and-finger
    connections on 3200 and 4000A breakers versus round primary disconnect on AKD-5. Uses inner-house drawout breaker
    compartment. Tuning fork primary disconnect (extrusion) on 800 - 2000A breaker compartments. Copper feeder breaker
    runbacks. 60” deep frames with 18” optional rear extension. Painted ANSI 61 light gray. Breakers have ECS or SST trip units.
    1981- AKD-8 Manufactured 1981 to present. Model 1 & 2 has extruded vertical bus. Model 2 introduced in 1983 to accommodate
    present automated wiring programs and harness routing. Model 3 introduced in 1991 using flat bar vertical bus. Breakers use
    MicroVersa Trip 9, RMS9, EPIC, MVT Plus, MVT PM trip units. Aluminum bus removed from design in 1996 in favor of standard
    tin-plated copper bus (silver plating optional). Field convertible space compartment design added to allow empty
    compartments to be modified to functioning breaker compartment without modifications to vertical bus.
    1998- AKD-10 Introduced March 1998 as the successor to AKD-8. Manufactured along with AKD-8 for 1998 and 1999. Uses only
    present WavePro low voltage power circuit breakers. Same dimensions as AKD-8. Only changes from AKD-8 are in the front breaker
    compartment — new drawout rails, breaker door, secondary disconnects instrument panel. No need for Remote Display
    for trip unit since WavePro breaker has trip unit in the escutcheon. AKD-10 can match & line-up with AKD-8 without a transition
    (for indoor and outdoor construction). Same bus structure, frame, options, layouts and breaker stacking as AKD-8.
    2005- Enblisys Introduced October 2005 as a new platb for low voltage switchgear. Uses non-automatic EnbliGuard
    present breakers (similar to WavePro except no current sensors, no trip unit, and limited accessories). Enblisys uses redundant
    components for highest reliability and maximum up-time. Redundant CPU’s perb all protection, metering, control,
    and monitoring functions. Other redundant components of the system include 2 UPS’s, 2 network communication
    switches for internal communication, 2 control power throwover relays, 2 control power sources (120vAC). Each breaker
    cubicle is provided with an EnbliGuard Messenger, which is the interface between the CPU’s and the circuit breaker
    operating mechanisms. The Messenger perbs A/D and D/A conversions plus provides back-up overcurrent proteciton
    for the breaker if all control power and communications are lost.
    Equipment construction is the same as AKD-10 switchgear (frame, bussing, drawout cubicles, etc). Enblisys does
    not replace AKD-10. Both product lines are currently being produced.
    2
    Switchgear
    2
    Prices and data subject Aftermarket Catalog www.geelectrical.com 2-3
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    Gerapid High Speed DC Circuit Breakers
    Technical Data for Rectifier Circuit Breaker Models 8007R and 10007R
    Breaker type Gerapid 8007R Gerapid 1007R
    Arc chute type 1x2 1x3 1x2 1x3
    Rated current In/A 6,000 6,000 8,000 8,000
    Rated operating voltage Ue/V 800 1,200 800 1,200
    Rated insulation voltage Ui/V 2,000 2,000 2,000 2,000
    120 min./A 7,200 7,200 9,600 9,600
    Short time current 2 min./A 8,000 8,000 16,000 16,000
    20 sec./A 12,000 12,000 24,000 24,000
    Mechanical endurance ops. 10,0001 10,0001 10,0001 10,0001
    Total weight approx. kg 220 220 220 220
    1With regular maintenance 100,000 ops.
    Figure 3. Gerapid 8007R and 10007R Rectifier CB, 1X2 Arc Chute, 800VDC
    (Dimensions in mm)
    Switchgear
    2
    2-4 Aftermarket Catalog www.geelectrical.com Prices and data subject
    to change without notice
    Low Voltage Power and DC Circuit Breakers
    AK and AKR Low Voltage Power Circuit Breakers
    New AK and AKR low voltage power circuit breakers are available for replacement and
    retrofill needs. The following circuit breakers are available:
    AK Circuit Breaker
    AC Voltage Rating Frame Size Short-circuit Ratings — RMS Symmetrical KA
    60 Hertz Breaker Type (Amps) With Instantaneous Trip Without Instantaneous Trip
    AK-25 600 22 22
    600 AK-50 1600 42 42
    AK-50H 1600 65 65
    AK-25 600 30 22
    480 AK-50 1600 50 50
    AK-50H 1600 65 65
    AK-25 600 42 22
    240 AK-50 1600 65 50
    AK-50H 1600 85 65
    AKR Circuit Breaker
    AC Voltage Rating Frame Size Short-circuit Ratings — RMS Symmetrical KA
    50/60 Hertz Breaker Type (Amps) With Instantaneous Trip Without Instantaneous Trip
    AKR-30 800 30 30
    AKR-30H 800 42 42
    600 AKR-50 1600 42 42
    AKR-50H 1600 65 65
    AKRT-50H 2000 65 65
    AKR-75 3200 65 65
    AKR-100 4000 85 85
    AKR-30 800 30 30
    AKR-30H 800 42 42
    480 AKR-50 1600 50 50
    AKR-50H 1600 65 65
    AKRT-50H 2000 65 65
    AKR-75 3200 65 65
    AKR-100 4000 85 85
    AKR-30 800 42 30
    AKR-30H 800 50 42
    240 AKR-50 1600 65 50
    AKR-50H 1600 65 65
    AKRT-50H 2000 65 65
    AKR-75 3200 85 65
    AKR-100 4000 130 85
    Contact your local GE sales representative for price and delivery. Be prepared to provide full
    nameplate data from your existing low voltage switchgear lineup.
    AK-25 Breaker
    AKR-30H Breaker
    Switchgear
    2
    Prices and data subject Aftermarket Catalog www.geelectrical.com 2-5
    to change without notice
    AK-25 Breaker with EnbliGuard? TU Trip Unit
    Low Voltage Power and DC Circuit Breakers
    Trip Unit Conversion Kits
    EnbliGuard? TU Conversion Kits
    GE offers a complete line of trip unit upgrade kits for low voltage
    power circuit breakers manufactured by GE, as well as by
    Westinghouse, I-T-E, and Allis-Chalmers. These conversion kits
    contain everything necessary to convert an old-style electromechanical
    or solid-state trip unit to today's latest electronic,
    digital technology—including the addition of metering, protective
    relay, waveb capture, RELT, and communication functions.
    All conversion kits designed by GE are tested to ANSI C37.59
    standards for each breaker type so customers have the
    assurance of safe, reliable operation.
    Features and Benefits–All Kits
    —Kit includes everything needed in one compact package
    —Full-range of interchangeable rating plugs
    —Trip targets for quick identification of overload, short circuit,
    and ground fault trips
    —Sealable, see-through cover to prevent unauthorized access to
    trip unit settings
    —Portable Trip Unit Test Kits; GTUTK20 and TVRMS2
    —Eliminate costly downtime due to nuisance tripping
    —Improved power system coordination and protection
    —Extend life and function of existing breakers and low voltage
    equipment
    EnbliGuard? TU Conversion Kits
    —True RMS sensing with a sampling rate of 48 samples per cycle
    with the ability to Waveb capture 4 cycles prior and 4 cycles
    after an event
    —Long Time, Short Time, and Instantaneous Standard on all trip
    units. S and I switchable on ANSI breakers
    —Large backlit LCD screen, view all currents on one screen
    —Trip settings and trip target inbation stored in non-volatile
    memory
    —On-board lithium battery (field replaceable) for cold set-up and
    reading trip targets
    —Status and Event Log, view the last 10 events
    —Health Status LED and Thermal Memory
    —Comm port for interface with set-up software and to download
    Waveb
    —Optional metering, relaying, communications, ZSI - I, ground
    fault (trip & alarm), and fused shaped curves
    —Plug and Play with previous generation of RMS9, EPIC, MVT and
    Enhanced MVT Trip Units
    ProTrip? Conversion Kits
    —Cost-effective upgrade with standard adjustable long time,
    short time, instantaneous, and defeatable ground fault functions
    —Simple-to-use rotary switches for selecting the trip unit pickup
    and delay settings
在線詢盤(pán)/留言
  • 免責(zé)聲明:以上所展示的信息由企業(yè)自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布企業(yè)負(fù)責(zé),本網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。我們?cè)瓌t 上建議您選擇本網(wǎng)高級(jí)會(huì)員或VIP會(huì)員。