    3 Molded-Case Circuit Breakers
    Replacement Capabilities
    Series C 30 mA Ground Fault
    (Earth Leakage)
    The Series C units (prefix only
    listed below) that included a
    breaker and integral Earth
    Leakage module have been
    replaced by the Series G
    solution that has the flexibility
    to add the Earth Leakage
    module in the field. The
    Series G solution has an
    extended range of 15–630A.
    Series C 30 mA Ground
    Fault (Earth Leakage)
    Note: Please contact Eaton
    customer service for assistance
    with crossing from the obsolete
    product to the new Series G.
    Ampere Range—15–400A
    Catalog Prefix
    Three-Pole Four-Pole
    ELFD EL4FD
    ELFW EL4FW
    ELHMCP EL4HFD
    ELHFD EL4HFW
    ELHFW EL4HJW
    ELHJD EL4HKW
    ELHJW EL4JW
    ELHKD EL4KW
    ELHKW —
    ELJD —
    ELJW —
    ELKD —
    ELKW —
    Earth Leakage
    Ampere
    Rating
    Series C
    Four-Pole
    Series G
    MCCB
    Series G
    MCCB
    Alt
    Series G Earth
    Leakage Module
    15 EL4FD3015L EGS4015FFG EGC4015FFG ELEBN4125G
    20 EL4FD3020L EGS4020FFG EGC4020FFG ELEBN4125G
    25 EL4FD3025L EGS4025FFG EGC4025FFG ELEBN4125G
    30 EL4FD3030L EGS4030FFG EGC4030FFG ELEBN4125G
    35 EL4FD3035L EGS4035FFG EGC4035FFG ELEBN4125G
    40 EL4FD3040L EGS4040FFG EGC4040FFG ELEBN4125G
    45 EL4FD3045L EGS4045FFG EGC4045FFG ELEBN4125G
    50 EL4FD3050L EGS4050FFG EGC4050FFG ELEBN4125G
    60 EL4FD3060L EGS4060FFG EGC4060FFG ELEBN4125G
    70 EL4FD3070L EGS4070FFG EGC4070FFG ELEBN4125G
    80 EL4FD3080L EGS4080FFG EGC4080FFG ELEBN4125G
    90 EL4FD3090L EGS4090FFG EGC4090FFG ELEBN4125G
    100 EL4FD3100L EGS4100FFG EGC4100FFG ELEBN4125G
    110 EL4FD3110L EGS4110FFG EGC4110FFG ELEBN4125G
    125 EL4FD3125L EGS4125FFG EGC4125FFG ELEBN4125G
    150 EL4FD3150L JGE4150FAG JGC4150FAG ELJBN4150W
    50 EL4FW3050JL GES4050AFM — ELEBE4125G
    50 EL4FWC3050JL GEC4050AFM — ELEBE4125G
    15 EL4HFD3015L EGH4015FFG — ELEBN4125G
    20 EL4HFD3020L EGH4020FFG — ELEBN4125G
    25 EL4HFD3025L EGH4025FFG — ELEBN4125G
    30 EL4HFD3030L EGH4030FFG — ELEBN4125G
    35 EL4HFD3035L EGH4035FFG — ELEBN4125G
    40 EL4HFD3040L EGH4040FFG — ELEBN4125G
    45 EL4HFD3045L EGH4045FFG — ELEBN4125G
    50 EL4HFD3050L EGH4050FFG — ELEBN4125G
    60 EL4HFD3060L EGH4060FFG — ELEBN4125G
    70 EL4HFD3070L EGH4070FFG — ELEBN4125G
    80 EL4HFD3080L EGH4080FFG — ELEBN4125G
    90 EL4HFD3090L EGH4090FFG — ELEBN4125G
    100 EL4HFD3100L EGH4100FFG — ELEBN4125G
    110 EL4HFD3110L EGH4110FFG — ELEBN4125G
    125 EL4HFD3125L EGH4125FFG — ELEBN4125G
    150 EL4HFD3150L JGH3150FAG — ELJBN4150W
    Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-65
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    3 Molded-Case Circuit Breakers
    Replacement Capabilities
    Portable Test Kit and Remote
    Ground Fault Trip Indicator
    Portable Test Kit
    Provides verification of
    perbance of all frame
    sizes of SELTRONIC breakers
    while devices are still in
    service under varying load
    and/or phase unbalance.
    The tester operates on
    120V, 50/60 Hz, and includes
    complete instructions and
    test times for testing the long
    time, instantaneous operation
    and optional ground fault
    operation of the breaker.
    Portable Test Kit
    Remote Ground Fault
    Trip Indicator
    For use only with SELTRONIC
    circuit breakers (LCG, HLCG,
    MCG, HMCG, NCG, HNCG,
    PCG and PCCG) with built-in
    ground fault protection.
    Note: UL Listed as a recognized
    component.
    The SELTRONIC ground fault
    indicator is a remoby
    mounted device with a
    combination indicating light/
    reset/test button that will
    light when the breaker trips
    on a ground fault. Tripping
    from overloads or short
    circuits will not activate the
    device. A separate 120V,
    50/60 Hz power source is
    required to power the light
    and internal relay, which
    has 1NO/1NC contacts
    for customer connected
    alarm, etc. Designed for
    panel mounting, it can be
    face-mounted by ordering
    the optional mounting
    bracket below.
    Remote Ground
    Fault Indicator
    Face Mounting Bracket
    Face Mounting Bracket for
    Ground Fault Indicator
    Style Number
    STK2
    Style Number Catalog Number
    1259C14G01 GFAU
    Style Number
    1264C67G01
    V12-T3-66 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    3 Molded-Case Circuit Breakers
    Replacement Capabilities
    Accessories
    Rear-Connected Studs
    For complete stud assembly,
    order a stud and an
    appropriate tube based on
    thickness of customer’s
    mounting panel. A short stud
    must be assembled adjacent
    to a long stud to maintain
    bances required by
    Underwriters Laboratories.
    400A LA studs of the
    same length have sufficient
    bance; however, customer
    connections may make it
    necessary to use a short stud
    adjacent to a long stud. Two
    studs are required per pole.
    Refer to DS29171 Dimension
    Sheets for stud sizes and
    extensions behind breaker.
    For DA, EB, EHB, FB, JA, KA, JB, KB, LB, LBB, HFB, HKA, HKB and HLB Breakers 1
    Notes
    1 For insulated panels only; two required per pole.
    2 Not UL Listed.
    3 Included at no charge when ordered with stud.
    Mounting Panel
    Thickness, Inches
    Stud 2 Tube 3
    Length Style Number Length Style Number
    DA, LB, LBB and HLB Breakers
    3/4–1 Short 656D565G03 27/32 313C909H17
    3/4–1 Long 656D565G04 3-25/32 313C909H20
    1/2–3/4 Short 656D565G03 1-3/32 313C909H18
    1/2–3/4 Long 656D565G04 4-1/32 313C909H21
    1/4–1/2 Short 656D565G03 1-11/32 313C909H19
    1/4–1/2 Long 656D565G04 4-9/32 313C909H22
    EB, EHB, FB and HFB (100A Maximum)
    1 Short 451D874G01 1-1/16 32B9446H20
    1 Long 451D874G02 3-7/16 32B9446H24
    1-1/16–15/16 Short 451D874G01 1-3/8 32B9446H21
    1-1/16–15/16 Long 451D874G02 3-3/4 32B9446H25
    3/8–5/8 Short 451D874G01 1-11/16 32B9446H22
    3/8–5/8 Long 451D874G02 4-1/16 32B9446H26
    1/4–5/16 Short 451D874G01 2 32B9446H23
    1/4–5/16 Long 451D874G02 4-3/8 32B9446H27
    FB, HFB 150 Ampere Breakers
    1 Short 374D883G01 1-1/16 374D883H06
    1 Long 374D883G02 4-5/16 374D883H10
    11/16–15/16 Short 374D883G01 1-3/8 374D883H07
    11/16–15/16 Long 374D883G02 4-5/8 374D883H11
    3/8–5/8 Short 374D883G01 1-11/16 374D883H08
    3/8–5/8 Long 374D883G02 4-15/16 374D883H12
    1/4–5/16 Short 374D883G01 2 374D883H09
    1/4–5/16 Long 374D883G02 5-1/4 374D883H13
    JA, KA and HKA Breakers
    3/4–1 Short 656D565G01 27/32 456D983H05
    3/4–1 Long 656D565G02 3-25/32 456D983H08
    1/2–3/4 Short 656D565G01 1-3/32 456D983H06
    1/2–3/4 Long 656D565G02 4-1/32 456D983H09
    1/4 –1/2 Short 656D565G01 1-11/32 456D983H07
    1/4 –1/2 Long 656D565G02 4-9/32 456D983H10
    JB, KB and HKB Breakers
    3/4–1 Short 5010D23G01 27/32 456D983H05
    3/4–1 Long 5010D23G02 3-7/8 5010D23H05
    1/2–3/4 Short 5010D23G01 1-3/32 456D983H06
    1/2–3/4 Long 5010D23G02 4-1/8 5010D23H06
    1/4 –1/2 Short 5010D23G01 1-11/32 456D983H07
    1/4 –1/2 Long 5010D23G02 4-3/8 5010D23H07
    Rear Connected Stud
    Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-67
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    3 Molded-Case Circuit Breakers
    Replacement Capabilities
    For LAB, LA, MA, HLA, HMA and HNB Breakers 1
    Notes
    1 For insulated panels only; two required per pole.
    2 150, 250, 300 and 400A frames only.
    3 This is a special stud that includes six contact nuts for use where bus contact nuts
    must be used.
    4 600A frames only.
    Stud Ampere
    Rating
    Diameter, Inches
    and Thread
    Extension Back
    of Breaker, Inches
    Stud
    Style Number
    LAB, LA, HLA, LC and HLC Breakers
    225 2 1/2–13 3-7/32 1241 345
    225 2 1/2–13 6-9/32 1241 346
    225 23 1/2–13 4-31/32 1241 392
    400 2 3/4–16 5-15/32 5B7383G15
    400 2 3/4–16 7-31/32 5B7383G16
    400 2 3/4–16 10-15/32 5B7383G17
    600 4 1–12 5-29/32 314C960G07
    600 4 1–12 5-13/32 314C960G08
    600 4 1–12 5-29/32 314C960G09
    MA, HMA, MC, HMC, MD and MDS Breakers
    225 1/2–13 3-21/32 314C960G01
    400 3/4–16 5-29/32 314C960G04
    400 3/4–16 8-13/32 314C960G05
    400 3/4–16 10-29/32 314C960G06
    600 1–12 5-29/32 314C960G07
    600 1–12 8-13/32 314C960G08
    600 1–12 10-29/32 314C960G09
    800 1-1/8–12 5-29/32 314C960G10
    800 1-1/8–12 8-13/32 314C960G11
    800 1-1/8–12 10-29/32 314C960G12
    NB, HNB, NC and HNC Breakers
    800 1-1/8–12 5-1/2 623B222G01
    800 1-1/8–12 8 623B222G02
    800 1-1/8–12 10-1/2 623B222G03
    1200 1-1/4–12 5-1/2 373B375G04
    1200 1-1/4–12 10-1/2 373B375G03
    V12-T3-68 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    3 Molded-Case Circuit Breakers
    Replacement Capabilities
    Panelboard Connecting Straps
    For connecting line end of breakers to panelboard bus.
    For DA, EB, EHB, FB, JA, KA, JB, KB, LB,
    LBB, HFB, HKB and HLB Breakers
    For CA, LAB, LA, MA, HLA, HMA and HNB Breakers
    Notes
    1 Not UL Listed.
    2 Bus spacing 2.75 inches in box 5.75 inches deep (600V maximum).
    3 Bus spacing 3.50 inches.
    Ampere Rating Connector Type 1 Style Number
    EB, EHB, FB and HFB Breakers
    Narrow Distribution Panelboards 2
    50 Center 673B142G02
    50 Outside 673B142G09
    100 Center 673B142G02
    100 Outside 673B142G10
    150 Center 673B142G04
    150 Outside 673B142G03
    Power Panelboards (Convertible) 3
    50 Center 1253C72G01
    50 Outside 1253C72G03
    100 Center 1253C73G03
    100 Outside 1253C73G06
    150 Center 1253C73G01
    150 Outside 1253C73G05
    Three-pole mounting bracket 624B600H01
    Two-pole mounting bracket 624B600H02
    DA, LB, LBB and HLB Breakers 3
    400 Center 314C940G04
    400 Outside 505C680G01
    Mounting bracket (one required) 208B264H01
    JA, KA and HKA Breakers 3
    225 Center 314C940G03
    225 Outside 180C074G01
    Mounting bracket (one required) 208B264H01
    JB, KB and HKB Breakers 3
    250 Center 2600D26G01
    250 Outside 2600D26G02
    Mounting bracket (one required) 1576707
    Panelboard
    Connecting Strap Ampere Rating Connector Type 1 Style Number
    CA Breaker Power Panelboards (Convertible) 3
    225 Center 1253C74G01
    225 Outside 1253C74G02
    Three-pole mounting bracket 624B624H01
    Two-pole mounting bracket 624B624H02
    LAB, LA, HLA, LC, HLC 150, 300 and 400A Frames 3
    400 Center 32B4570G02
    400 Outside 314C541G01
    Mounting bracket (two required) 208B297H01
    LA, HLA, LC and HLC 600A Frames 3
    600 Center 624B609G01
    600 Outside 506C052G01
    Mounting bracket (two required) 208B297H01
    MA, HMA, MC, HMC, MD and MDS Breakers 3
    800 Short 314C996G01
    800 Medium 314C996G02
    800 Long 314C996G03
    Mounting bracket (four required) 315C270H01
    NB, HNB, NC and HNC Breakers 3
    1200 Short 505C606G04
    1200 Medium 505C606G05
    1200 Long 505C606G06
    Mounting bracket (four required) 315C270H01
    Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-69
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    3 Molded-Case Circuit Breakers
    Replacement Capabilities
    Plug-In Adapter Kits
    For rear-connected applications such as switchboards.
    Facilitates ease of installation and front removal of breaker.
    Includes conductor for mounting on breaker, plug-in mounting
    blocks with matching conductor, rear studs and mounting
    hardware. Order two mounting blocks style number when line
    and load are required; order one mounting block style number
    when either line or load is required.
    ■Shaded area denotes obsolete or discontinued products
    and services. 1
    Flat Bus Type
    Threaded Studs Type
    Mounting Plates
    Notes
    1 These accessories are no longer available.
    2 These plug-in adapter kits are UL Listed as recognized
    components.
    3 700–1200A adapter kit is front removable, bolt-on design—
    not plug-in type.
    4 Not UL Listed.
    Debion Style Number
    EB, EHB, FB Thermal-Magnetic Breakers 2
    Flat Bus Type—One Mounting Block, Line or Load
    Two-pole, 100A 1480D13G05
    Two-pole, 150A 1480D13G05
    Three-pole, 100A 1480D13G06
    Three-pole, 150A 1480D13G06
    FB and HFB Magnetic Only, HFB Thermal-Magnetic 2
    Flat Bus Type—One Mounting Block, Line or Load
    Two-pole, 100A 1480D13G05
    Two-pole, 150A 1480D13G05
    Three-pole, 100A 1480D13G06
    Three-pole, 150A 1480D13G06
    JB, KB, HKB Breakers 1 Flat Bus Type—
    Two Mounting Blocks, Line and Load
    Two-pole 506C144G17
    Three-pole 506C144G18
    One Mounting Block, Line Only
    Two-pole 1260C86G01
    Three-pole 1260C86G02
    Two-pole 1260C86G03
    Three-pole 1260C86G04
    LAB, LA, HLA, LC and HLC (150, 250, 300 and
    400A Frame) (Threaded Studs Type)—
    Two Mounting Blocks, Line and Load
    Two-pole 313C644G25
    Three-pole 313C644G26
    One Mounting Block, Line or Load
    Two-pole 450D010G15
    Three-pole 450D010G16
    DA, LB, LBB, HLB Breakers 2 Flat Bus Type—
    Two Mounting Blocks, Line and Load
    Two-pole 313C644G45
    Three-pole 313C644G46
    One Mounting Block, Line or Load
    Two-pole 314C932G03
    Three-pole 314C932G04
    MA, HMA, MC, HMC, MD and MDS Breakers 3
    Threaded Studs—Two Mounting Blocks,
    Line and Load
    Two-pole, 125–600A 313C644G27
    Two-pole, 700–800A 176C544G01 3
    Three-pole, 125–600A 313C644G28
    Three-pole, 700–800A 176C544G02 3
    One Mounting Block, Line or Load
    Two-pole, 125–600A 313C370G03
    Two-pole, 700–800A 507C049G01 3
    Three-pole, 125–600A 313C370G04
    Three-pole, 700–800A 507C049G02 3
    Flat Bus Type
    Debion Style Number
    JA, KA and HKA Breakers 4 (Threaded Studs
    Type)—Two Mounting Blocks, Line and Load
    Two-pole 313C644G29
    Three-pole 313C644G30
    One Mounting Block, Line or Load
    Two-pole 314C932G01
    Three-pole 314C932G02
    LA, HLA, LC and HLC (600A Frames) 2 (Threaded
    Studs)—Two Mounting Blocks, Line and Load
    Two-pole 313C644G50
    Three-pole 313C644G51
    One Mounting Block, Line or Load
    Two-pole 506C059G03
    Three-pole 506C059G04
    One Mounting Block, Line or Load Flat Bus Type
    Two-pole 1288C19G01
    Three-pole 1288C19G02
    MA, HMA, MC, HMC, MD, MDS, NB, HNB, NC, HNC
    and NB TRI-PAC Breakers 4 (Flat Bus Type)—
    One Mounting Block, Line or Load
    MA, HMA, MC, HMC, MD, MDS two-pole 2614D53G05
    MA, HMA, MC, HMC, MD, MDS three-pole 2614D53G06
    NB, HNB, NC, HNC, NB TRI-PAC two-pole 2614D53G03
    NB, HNB, NC, HNC, NB TRI-PAC three-pole 2614D53G04
    Debion Style Number
    Predrilled panels for:
    EB, EHB, FB, HFB 507C047H01
    JB, KB 179C207H01
    JA, KA 504C823H01
    DA, LB, LBB, ALB 178C781H01
    LA, LAB, HLA, LC, HLC 504C824H01
    MA, HMA, MC, MMC, NB, HNB, NC, HNC 1290C73H01
    Threaded Stud Type
    V12-T3-70 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    3 Molded-Case Circuit Breakers
    Replacement Capabilities
    Extended Line Terminal Shields
    For shielding line side terminal connections. One shield required
    per breaker. Order separaby when needed. Sold only in lots of
    10, including hardware.
    Extended Line Terminal Shields 1
    Base Mounting Hardware
    No charge when ordered with breaker. Order separaby
    when needed.
    Base Mounting Hardware
    Fuse Mounting Base for PB Breakers
    For 2000A non-automatic breakers only.
    Fuse Mounting Base for PB Breakers
    For use with non-automatic, three-pole circuit breaker. Includes
    fuse mounting base and hardware to mount standard Class L
    current limiting fuses, 801–2000A (fuses not included).
    Note: Interrupters used with fuse mounting base will accept all standard
    PB accessories. See Dimension Sheet 29-171 for mounting details.
    Breaker Frame Style Number
    JB, KB, HKB 1266C07G01
    MA, HMA, MC, HMC 208B966G01
    NB, HNB, NC, HNC 208B966G02
    LAB, LA, (Saf-T-Vue) 314C420G02
    JA, KA, LB, LBB (Saf-T-Vue) 314C420G04
    LAB, LA, HLA, LC, HLC 314C420G05
    DA 314C420G06
    JA, KA, HKA, LB, LBB, HLB (standard breaker) 314C420G06
    EB, EHB, FB, HFB 625B229G08 2
    Debion Style Number
    Single-Pole Breakers
    EB, EHB, HFB 3 624B375G01
    EB, EHB, HFB 4 624B375G02
    Two- and Three-Pole Breakers
    LAB, LA, HLA, LC, HLC, MA, NB, HMA, HNB, MC 21C6782G05
    HMC, NC, HNC 1091716
    PB, PC, PCC 624B375G22
    DA, JA, KA, HKA, LB, LBB, HLB 21C6782G22
    EB, EHB, FB, HFB, MCP 21C6782G18
    JB, KB, HKB 673B125G12
    CA two-pole 21C6782G28
    CA three-pole 21C6782G29
    Style Number
    6635C78G02 1
    Line Terminal Shield
    Line Terminal Shield
    For complete installation, order:
    1. Front-connected, non-automatic PB breaker.
    (Order similar to standard front connected, except
    omit load conductor extensions.)
    2. Fuse mounting base.
    3. Fuses (from distributor).
    Handle Locks
    Non-Padlockable
    For prevention of unintentional operation of breaker. Fits over
    breaker handle and may be removed.
    Padlockable
    For prevention of unauthorized operation of breaker. Is nonremovable
    once installed on breaker. Meets Underwriters
    Laboratories and California Code requirements.
    Handle Locks 15
    Notes
    1 Not UL Listed.
    2 One of style 625B229G08 is one package of 10.
    3 Individually mounted.
    4 Group mounted.
    5 All breakers are trip free and will trip with handle locks attached.
    Cannot be used when handle extension is used.
    Breaker Frame Style Number
    Non-Padlockable
    FA, EA, CA, EB, EHB, FB, HFB 29B2721H01
    LAB, LA, LC, HLC, MA, NB, HLA, HMA, HNB,
    MC, HMC, NC, HNC
    28B4596G01
    GB, GC, GHB, GHC 1294C01H01
    DA, JA, KA, HKA, LB, LBB, HLB 29B2721H04
    Padlockable
    CA 506C438G01
    FA, EA, EB, EHB, FB, HFB, MCP150 765A754G01
    DA, JA, KA, LB, LBB, HKA, HLB, MCP400 673B796G02
    JB, KB, HKB, MCP250 673B796G01
    LAB, LA, HLA, LC, HLC 373B591G02
    MA, HMA, MC, HMC, MD, MDS 6591C30G02–OFF
    MA, HMA, MC, HMC, MD, MDS 6591C30G05–ON/OFF
    NB, HNB, NC, HNC 6591C30G01–OFF
    NB, HNB, NC, HNC 6591C30G04–ON/OFF
    PA, SPCB, PB, Tri-Pac PB, PC 6591C30G03–OFF
    Handle Locks
    Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-71
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    3 Molded-Case Circuit Breakers
    Replacement Capabilities
    Cable Connectors
    The fuse mounting base will accept the following terminals
    for front cable connection (omit “T” connectors from rear
    connected breakers).
    Cable Connectors
    Molded Type Handle Extension
    For LAB, LA and HLA Breakers 1
    For MA, HMA, MC, HMC, NB, HNB, NC and HNC Breakers 1
    For PB, PC, PCC and PA/RD Breakers 1
    Wire Range, Type Number of Cables Style Number
    (3) 3/0–400 kcmil Cu 672B655G01
    (4) 400–500 kcmil Cu 180C046G03
    Style Number
    372B399G01
    Style Number
    1251C65G01 2
    Style Number
    6635C78G02 2
    Modifications
    Only two internally mounted
    modifications—shunt trip,
    undervoltage release,
    auxiliary switch, alarm
    switch—may be mounted
    in EB through PB. Only one
    of these modifications may
    be mounted in FB, HFB
    magnetic only, two-pole EB,
    EHB, FB and SELTRONIC
    breakers. None are available
    in single-pole breakers except
    alarm switch in EB, EHB and
    HFB. Contact Avery Creek,
    NC, Technical Resource
    Center for possible special
    combinations of the following
    modifications not in
    tabulations. Contact factory
    for pricing if accessories
    are factory installed.
    Shunt Trip
    For tripping breaker from
    a remote point. A solenoid
    device mounts within breaker
    case. Breaker trips when
    coil is energized.
    Shunt trips should not be
    used as circuit interlocks
    using maintained contact
    pilot devices.
    A cutoff switch breaks the
    circuit to the momentary rated
    coil when the breaker opens.
    Available for control voltages
    up to 250 Vdc or 600 Vac.
    Voltage and frequency must
    be specified. Standard leads
    extend 18.00 inches outside
    the breaker. Longer leads may
    be specified.
    Factory-Mounted Shunt Trips
    Factory-mounted shunt trips
    only can be supplied for the
    following breakers: CA, HCA,
    CAH, HFB magnetic only
    and PB/PBF non-automatic
    breakers (molded-case
    switches). They are 120 Vac
    rated, suitable for 55% pickup
    for ground fault application.
    Right hand mounting is
    standard and they are not
    UL Listed.
    Notes
    1 Not UL listed.
    2 Included with frame at no charge.
    V12-T3-72 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    3 Molded-Case Circuit Breakers
    Replacement Capabilities
    ■Shaded area denotes obsolete or discontinued products and services. 4
    Shunt Trip for Field Mounting 123
    Notes
    1 120 Vac ratings suitable for 55% pickup for ground fault applications.
    2 Not field mountable on non-automatic breakers (molded-case switches).
    3 Field mounting voids breakers’ UL listing except on LA, HLA, MA, HMA, NB, HNB, PB, KB, HKB, KA, HKA, LB, HLB and SELTRONIC breakers.
    4 These frames are obsolete. For replacement solutions, see the cross-reference on Pages V12-T3-114–V12-T3-168.
    5 Available similar to this except “Leads out the load end—(not UL Listed).” Order by debion.
    Voltage/Hz
    Breaker Type Catalog Number
    EB, EHB, FB, HFB 5
    (Thermal-Magnetic Only) JB, KB, HKB
    JA, KA, HKA, DA,
    LB, LBB, HLB LA, LAB, HLA MA, HMA NB, HNB
    PB TRI-PAC
    and PA
    Right-Hand Mounting
    600/50–60 Hz 2609D39G15 2609D42G15 2605D15G15 2606D56G15 2606D57G15 2606D58G15 2606D59G15
    480/50–60 Hz 2609D39G16 2609D42G16 2605D15G16 2606D56G16 2606D57G16 2606D58G16 2606D59G16
    240/50–60 Hz 2609D39G17 2609D42G17 2605D15G17 2606D56G17 2606D57G17 2606D58G17 2606D59G17
    208/50–60 Hz 2609D39G18 2609D42G18 2605D15G18 2606D56G18 2606D57G18 2606D58G18 2606D59G18
    120/50–60 Hz 2609D39G19 2609D42G19 2605D15G19 2606D56G19 2606D57G19 2606D58G19 2606D59G19
    60/50–60 Hz 2609D39G20 2609D42G20 2605D15G20 2606D56G20 2606D57G20 2606D58G20 2606D59G20
    48/50–60 Hz 2609D39G21 2609D42G21 2605D15G21 2606D56G21 2606D57G21 2606D58G21 2606D59G21
    24/50–60 Hz 2609D39G22 2609D42G22 2605D15G22 2606D56G22 2606D57G22 2606D58G22 2606D59G22
    250 DC 2609D39G23 2609D42G23 2605D15G23 2606D56G23 2606D57G23 2606D58G23 2606D59G23
    125 DC 2609D39G24 2609D42G24 2605D15G24 2606D56G24 2606D57G24 2606D58G24 2606D59G24
    60 DC 2609D39G25 2609D42G25 2605D15G25 2606D56G25 2606D57G25 2606D58G25 2606D59G25
    48 DC 2609D39G26 2609D42G26 2605D15G26 2606D56G26 2606D57G26 2606D58G26 2606D59G26
    24 DC 2609D39G27 2609D42G27 2605D15G27 2606D56G27 2606D57G27 2606D58G27 2606D59G27
    12 DC 2609D39G28 2609D42G28 2605D15G28 2606D56G28 2606D57G28 2606D58G28 2606D59G28
    Left-Hand Mounting
    600/50–60 Hz 2609D39G01 2609D42G01 2605D15G01 2606D56G01 2606D57G01 2606D58G01 2606D59G01
    480/50–60 Hz 2609D39G02 2609D42G02 2605D15G02 2606D56G02 2606D57G02 2606D58G02 2606D59G02
    240/50–60 Hz 2609D39G03 2609D42G03 2605D15G03 2606D56G03 2606D57G03 2606D58G03 2606D59G03
    208/50–60 Hz 2609D39G04 2609D42G04 2605D15G04 2606D56G04 2606D57G04 2606D58G04 2606D59G04
    120/50–60 Hz 2609D39G05 2609D42G05 2605D15G05 2606D56G05 2606D57G05 2606D58G05 2606D59G05
    60/50–60 Hz 2609D39G06 2609D42G06 2605D15G06 2606D56G06 2606D57G06 2606D58G06 2606D59G06
    48/50–60 Hz 2609D39G07 2609D42G07 2605D15G07 2606D56G07 2606D57G07 2606D58G07 2606D59G07
    24/50–60 Hz 2609D39G08 2609D42G08 2605D15G08 2606D56G08 2606D57G08 2606D58G08 2606D59G08
    250 DC 2609D39G09 2609D42G09 2605D15G09 2606D56G09 2606D57G09 2606D58G09 2606D59G09
    125 DC 2609D39G10 2609D42G10 2605D15G10 2606D56G10 2606D57G10 2606D58G10 2606D59G10
    60 DC 2609D39G11 2609D42G11 2605D15G11 2606D56G11 2606D57G11 2606D58G11 2606D59G11
    48 DC 2609D39G12 2609D42G12 2605D15G12 2606D56G12 2606D57G12 2606D58G12 2606D59G12
    24 DC 2609D39G13 2609D42G13 2605D15G13 2606D56G13 2606D57G13 2606D58G13 2606D59G13
    12 DC 2609D39G14 2609D42G14 2605D15G14 2606D56G14 2606D57G14 2606D58G14 2606D59G14
    Shunt Trip
    Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-73
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    3 Molded-Case Circuit Breakers
    Replacement Capabilities
    Left-Hand Mounting Kits for SELTRONIC Breakers
    Left-Hand Mounting Kits for SELTRONIC Breakers
    Shunt Trip Coil Data
    Notes
    1 Rated 48V minimum for ground fault applications.
    2 Also available for 24 Vdc. Order by debion.
    3 Not for ground fault.
    Debion
    Breaker
    Type
    Style
    Number
    Provision to trip flux transfer shunt trip from
    external 32 to 120 Vdc and Vac to 60 Hz source 12
    MC, HMC 1371D72G22
    NC, HNC 1372D39G13
    PC, PCC 1372D35G22
    LC, HLC 1371D11G22
    Provision to trip flux transfer shunt trip from
    external 240 to 600 Vac, 50/60 Hz source 23
    MC, HMC 1371D72G32
    NC, HNC 1372D39G23
    PC, PCC 1372D35G32
    LC, HLC 1371D11G32
    Shunt Trip
    Voltage
    Rating
    For All Breakers Listed in Previous
    Table and on Previous Page
    Except CA and SELTRONIC SELTRONIC
    Coil Inrush Coil Inrush
    Amperes Volt-Amperes Amperes Volt-Amperes
    600 AC 0.105 63.0 — —
    480 AC 0.085 40.8 — —
    240 AC 1.7 408.0 — —
    208 AC 1.4 291.2 — —
    120 AC 0.88 105.6 15 18
    60 AC 9.10 546.0 — —
    48 AC 7.50 360.0 — —
    24 AC 3.95 94.8 — —
    250 DC 2.5 625.0 — —
    125 DC 0.975 121.9 — —
    60 DC 0.525 31.5 — —
    48 DC 1.3 62.4 — —
    24 DC (FB) 6 144.0 — —
    24 DC (KB) 3.8 91.2 — —
    24 DC (others) 8 192 — —
    12 DC 6 72 — —
    V12-T3-74 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    3 Molded-Case Circuit Breakers
    Replacement Capabilities
    Standard Undervoltage Release
    For undervoltage protection.
    A solenoid device mounts
    within a breaker case. Coil
    must be energized before
    closing breaker. Trips breaker
    when voltage drops below 35
    to 70% of coil rating. Picks
    up and seals in at 85% of coil
    rating. For line voltages
    up to 250 Vdc or 600 Vac.
    Externally mounted resistors
    are supplied for certain
    ratings. Standard leads
    extend 18.00 inches outside
    of breaker. Longer leads may
    be specified.
    Note: Undervoltage release
    attachments are not designed
    for, and should not be used as,
    circuit interlocks. For further
    inbation, Contact Avery
    Creek, NC, Technical Resource
    Center at 1-800-356-1243.
    Factory-Mounted
    Undervoltage Releases
    All of the above undervoltage
    releases can be specified for
    factory mounting. Contact
    factory for pricing. These
    attachments have the leads
    out the side and are UL
    Listed when factory mounted
    unless other non-UL Listed
    modifications are used.
    Note: Right-hand mounting
    is considered standard unless
    specified otherwise except JA,
    KA, DA, HKA, LB, LBB, HLB
    and SELTRONIC available
    for left-hand only. JB, KB, HKB
    are obsolete.
    Factory-mounted
    undervoltage releases
    only can be supplied for
    the following breakers:
    ● SELTRONIC breakers
    (120 Vac, 60 Hz only
    standard), MC, HMC, NC,
    HNC, PC, PCC, LC, HLC
    ● SELTRONIC breakers with
    remote trip provisions,
    MC, HMC 2, NC, HNC 2,
    PC, PCC 2, LC, HLC 2
    ● EB 3, EHB 3, FB 3, HFB 3,
    FB 45 and HFB magnetic
    only 45
    ● No UVR available for CA,
    CAH and HCA
    Undervoltage Release Attachment Kits for Field Mounting 67
    Notes
    1 Cannot be used with other attachments except a small 1A-1B auxiliary switch rated 250V can be supplied in
    right-hand pole.
    2 Provided with two leads (total of four) for use with a remote normally open contact (pushbutton, etc.) to trip the
    breaker. No external power required.
    3 Not available on ambient compensating breakers.
    4 Not UL Listed.
    5 Right-hand mounting only.
    6 Not field mountable on non-automatic breakers (molded-case switches).
    7 Field mounting voids UL listing of breaker except on LA, HLA, MA, HMA, NB, HNB, PB, KA, HKA, LB and HLB.
    Attachment
    Voltage, Hz
    Breaker Type
    JA, KA, DA, HKA,
    LB, LBB, HLB LA, LAB, HLA MA, HMA NB, HNB PB, PA 4
    For Right-Hand Mounting
    24, 60 — 60A9355G17 — — —
    48, 60 — 60A9355G08 — — 5674D29G16
    120, 60 — 60A9355G01 457D727G01 373D632G01 5674D29G09
    208, 60 — 60A9355G02 457D727G19 373D632G19 5674D29G10
    240, 60 — 60A9355G03 457D727G02 373D632G02 5674D29G11
    480, 60 — 60A9355G05 457D727G03 373D632G03 5674D29G13
    600, 60 — 60A9355G06 457D727G04 373D632G04 5674D29G14
    12 DC — 458D020G01 457D727G09 372D032G01 4976D85G01
    24 DC — 458D020G02 457D727G10 372D032G02 4976D85G02
    48 DC — 458D020G03 457D727G11 372D032G03 4976D85G03
    60 DC — 458D020G04 457D727G21 — 4976D85G04
    125 DC — 458D020G07 457D727G12 372D032G04 4976D85G07
    250 DC — 458D020G08 457D727G13 372D032G05 4976D85G08
    For Left-Hand Mounting
    48, 60 — 60A9355G16 — — 5674D29G08
    120, 60 458D070G01 60A9355G09 457D727G05 373D632G05 5674D29G01
    208, 60 458D070G05 60A9355G10 457D727G20 373D632G20 5674D29G02
    240, 60 458D070G02 60A9355G11 457D727G06 373D632G06 5674D29G03
    480, 60 458D070G03 60A9355G13 457D727G07 373D632G07 5674D29G05
    600, 60 458D070G04 60A9355G14 457D727G08 373D632G08 5674D29G06
    12 DC 458D070G09 458D020G11 457D727G14 372D032G06 4976D85G11
    24 DC 458D070G10 458D020G12 457D727G15 372D032G07 4976D85G12
    48 DC 458D070G11 458D020G13 457D727G16 372D032G08 4976D85G13
    60 DC — 458D020G14 457D727G22 — 4976D85G14
    125 DC 458D070G12 458D020G17 457D727G17 372D032G09 4976D85G17
    250 DC 458D070G13 458D020G18 457D727G18 372D032G10 4976D85G18
    Standard Undervoltage
    Release
    Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-75
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    3 Molded-Case Circuit Breakers
    Replacement Capabilities
    Undervoltage Release Coil Data
    Voltage
    Rating Hz
    Breaker Type
    EB, EHB, FB, HFB, JB, KB and HKB JA, KA, HKA, DA, LB, LBB and HLB LA, LAB, HLA and PB
    Coil
    Amperes
    External Series
    Resistance (Ohms)
    Total
    VA
    Coil
    Amperes
    External Series
    Resistance (Ohms)
    Total
    VA
    Coil
    Amperes
    External Series
    Resistance (Ohms)
    Total
    VA
    600 AC 0.020 25,000 12.0 0.012 50,000 7.2 0.029 20,000 17.4
    480 AC 0.016 20,000 7.7 0.013 30,000 6.3 0.014 — 6.8
    240 AC 0.021 6000 5.1 0.013 — 3.2 0.036 — 8.7
    208 AC 0.019 6000 4.0 0.018 — 3.8 0.036 — 7.5
    120 AC 0.023 — 2.8 0.023 — 2.8 0.073 — 8.8
    60 AC 0.203 250 12.2 — — — — — —
    48 AC 0.245 150 11.8 — — — 0.152 — 7.3
    24 AC 0.250 50 6.0 — — — — — —
    250 DC 0.026 5000 6.5 0.013 16,500 3.3 0.035 5000 8.8
    125 DC 0.026 — 3.3 0.013 6500 1.7 0.039 1500 4.9
    60 DC 0.248 200 14.9 0.013 1500 0.8 0.034 — 2.1
    48 DC 0.260 150 12.5 0.012 600 0.6 0.040 — 2.0
    24 DC 0.141 — 3.4 0.023 — 0.6 0.069 — 1.7
    12 DC 0.286 — 3.5 0.048 — 0.6 0.136 — 1.7
    MA and HMA NB and HNB MC, HMC, NC, HNC, PC, PCC, LC and HLC
    Coil
    Amperes
    External Series
    Resistance (Ohms)
    Total
    VA
    Coil
    Amperes
    External Series
    Resistance (Ohms)
    Total
    VA
    Coil
    Amperes
    External Series
    Resistance (Ohms)
    Total
    VA
    600 AC 0.012 50,000 7.2 0.016 35,000 9.6 — — —
    480 AC 0.013 30,000 6.3 0.013 30,000 6.3 — — —
    240 AC 0.013 — 3.2 0.013 — 3.2 — — —
    208 AC 0.018 — 3.8 0.018 — 3.8 — — —
    120 AC 0.023 — 2.8 0.023 — 2.8 0.5 — 6
    60 AC — — — — — — — — —
    48 AC — — — — — — — — —
    24 AC — — — — — — — — —
    250 DC 0.013 16,500 3.3 0.013 16,500 3.3 — — —
    125 DC 0.013 6500 1.7 0.013 6500 1.7 — — —
    60 DC 0.013 1500 0.8 — — — — — —
    48 DC 0.012 600 0.6 0.012 600 0.6 — — —
    24 DC 0.02 — 0.6 0.023 — 0.6 — — —
    12 DC 0.048 — 0.6 0.048 — 0.6 — — —
    V12-T3-76 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
    1
    2
    3
    4
    5
    6
    7
    8
    9
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    3 Molded-Case Circuit Breakers
    Replacement Capabilities
    Alarm Switch
    Availability: EB through PC.
    For light or alarm indication
    when breaker trips. Does
    not function with manual
    operation. Automatically
    resets when breaker is
    relatched. Standard leads
    extend 18.00 inches outside
    of breaker. Longer leads
    may be specified. Not
    field mountable.
    Alarm Switch Contact
    Rating (Non-Inductive)
    ● MC, HMC, LA, LAB, HLA,
    LC, HLC: 10A, 120 Vac;
    5A, 240 Vac
    ● EB, EHB, FB, HFB:
    5A, 120 Vac
    ● All other breakers:
    10A, 120–240 Vac
    Auxiliary Switch
    For auxiliary control circuits.
    Miniature switches mount
    within breaker. Commonly
    used for remote indication
    of open or closed breaker
    and electrically interlocking
    component control circuits.
    “A” contacts are closed
    when breaker is closed.
    “B” contacts are open when
    breaker is closed. Standard
    leads extend 18.00 inches
    outside of breaker. Longer
    leads may be specified.
    Note: Right-hand mounting
    standard for EB, EHB, FB, HFB,
    JB, KB and HKB. All others are
    left-hand mounting as standard
    unless otherwise specified.
    Factory-Mounted
    Auxiliary Switches
    All of the above auxiliary
    switches can be specified
    for factory mounting at the
    same price as listed for the
    kit. These attachments have
    the leads out the side of the
    breaker and are UL Listed
    when factory mounted
    unless other non-UL Listed
    modifications are used
    (except as noted).
    Note: Right-hand mounting
    standard for EB, EHB, FB, HFB,
    JB, KB and HKB. All others are
    left-hand mounting as standard
    unless otherwise specified.
    Factory-mounted switches
    only can be supplied for the
    following breaker:
    ● JB, LBB, LAB, JA, DA, FB l
    magnetic only 2m and HFB
    magnetic only 2m
    Switch Schematic
    Alarm Switch
    ■Shaded area denotes obsolete or discontinued products and services. 9
    Auxiliary Switch Attachment Kits for Field Mounting 678
    Notes
    1 Alarm switches are no longer available
    for these frames.?TCSESM083F2CU0,TCSESM083F2CS0,TCSESM063F2CU1,TCSESM083F1CU0
    施耐德 莫迪康--MODICON TCSESM083F2CU0 交換機(jī)
    TCSESM083F2CS0 交換機(jī)
    TCSESM163F2CU0 交換機(jī)
    TCSESM163F2CS0 交換機(jī)
    TCSESM243F2CU0 交換機(jī)
    TCSESM083F1CS0 交換機(jī)
    TCSESM083F1CU0 交換機(jī)
    TCSESM083F1CS0
    TCSESM063F2CU1
    TCSESM063F2CS1
    TCSESM083F1CU0
    499NSS25101
    499NSS25102
    499NMS25101
    499NMS25102
    TCSECN300R2
    TSXETG1000
    TSXETG1010
    174CEV20040
    TSXETG100
    TSXETG3000
    TSXETG3010
    TSXETG3021
    TSXETG3022
    TSXETGCF01GI
    499NES18100
    TCSESM043F2CU0
    TCSESM043F1CS0
    TCSESM043F2CS0
    TCSESM083F23F0
    TCSESM083F1CU0
    TCSESM083F1CS0
    TCSESM163F23F0
    TCSESM103F23G0
    TCSESM103F2LG0
    TCSEAAF1LFS00
    TCSEAAF1LFH00
    TCSESB083F23F0
    TCSESB083F2CU0
    TCSESB093F2CU0
    TCSESM103F23G0
    TCSESM103F2LG0
    TCSEAAF1LFS00
    TCSEAAF1LFH00
    TCSESM083F23F1
    TCSESM063F2CU1
    TCSESM063F2CS1?特別推薦公司優(yōu)勢(shì)庫(kù)存:
    140DAO84210?
    140DDI35310?
    140MSB10100 1
    140DRA84000 60?
    140CPU11303 57?
    140CPU67160 51?
    140BE10000 26?
    140DDI35300 22?
    140DDI85300 16?
    140CPS12400 10?
    140CPS11420 9?
    140DDO84300 9?
    140CPU65160 7?
    140CPU43412A 6?
    140NOM21100 6?
    140CPU65150 5?
    140CPU11302 5?
    140CPS11410 4?
    140CPU53414B 4?
    140CRA93200 4?
    140CRP93200 4?
    140NOE77101 4?
    140ARI03010 4?
    140ACI03000 3?
    140CRP93100 3?
    140CRP81100 2?
    140DAI55300 2?
    140CPS11100 2?
    140CPS22400 2?
    140CRA93100 2?
    140EHC10500 2?
    TSXAZY414 2?
    140ACI04000 1?
    140ACO02000 1?
    140AVI03000 1?
    140AVO02000 1?
    140CHS11000 1?
    140CRA21110 1?
    140DDO35300 1?
    140ESI06210 1?
    140NOE77100 1?
    140BP01600 1?
    PTQ-PDPMV1 140PTQ-PDPMV1 1?
    TSXP575634M 1?
    TSXPSY5500M 1?
    140DAO84000 1?
    施耐德莫迪康MODICON昆騰Quantum140PLC常規(guī)件
    現(xiàn)貨AS-BADU-205
    現(xiàn)貨AS-HDTA-200C
    現(xiàn)貨AS-HDTA-201
    現(xiàn)貨AS-HDTA-201C
    現(xiàn)貨AS-HDTA-202
    現(xiàn)貨AS-HDTA-202C
    現(xiàn)貨AS-MBKT-085
    現(xiàn)貨AS-MBKT-185
    現(xiàn)貨AS-MBPL-001
    現(xiàn)貨AS-MEEP-000
    現(xiàn)貨AS-P120-000
    現(xiàn)貨AS-P120-125
    現(xiàn)貨AS-WBXT-201
    現(xiàn)貨AS-WBXT-203
    現(xiàn)貨AS-BADU-206
    現(xiàn)貨AS-BADU-210
    現(xiàn)貨AS-BADU-211
    現(xiàn)貨AS-BADU-212
    現(xiàn)貨AS-BADU-214
    現(xiàn)貨AS-BADU-216
    現(xiàn)貨AS-BADU-254
    現(xiàn)貨AS-BADU-254C
    現(xiàn)貨AS-BADU-256
    現(xiàn)貨AS-BADU-256C
    現(xiàn)貨AS-BADU-257
    現(xiàn)貨AS-BADU-257C
    現(xiàn)貨AS-BBKF-201
    現(xiàn)貨AS-BBKF-202
    現(xiàn)貨AS-BCTR-205
    現(xiàn)貨AS-BCTR-212
    現(xiàn)貨AS-BCTR-224
    現(xiàn)貨AS-BDA0-216
    現(xiàn)貨AS-BDAP-204
    現(xiàn)貨AS-BDAP-208
    現(xiàn)貨AS-BDAP-210
    現(xiàn)貨AS-BDAP-211
    現(xiàn)貨AS-BDAP-212
    現(xiàn)貨AS-BDAP216N
    現(xiàn)貨AS-BDAP-217
    現(xiàn)貨AS-BDAP-218
    現(xiàn)貨AS-BDAP-220
    現(xiàn)貨AS-BDAP-250
    現(xiàn)貨AS-BDAP-250C
    現(xiàn)貨AS-BDAP-252
    現(xiàn)貨AS-BDAP-252C
    現(xiàn)貨AS-BDAP-253
    現(xiàn)貨AS-BDAP-253C
    現(xiàn)貨AS-BDAP-258
    現(xiàn)貨AS-BDAP-258C
    現(xiàn)貨AS-BDAP-292
    現(xiàn)貨AS-BDAU-202
    現(xiàn)貨AS-BDAU-208
    現(xiàn)貨AS-BDE0-216
    現(xiàn)貨AS-BDEA-202
    現(xiàn)貨AS-BDEA-203
    現(xiàn)貨AS-BDEP-208
    現(xiàn)貨AS-BDEP-210
    現(xiàn)貨AS-BDEP-211
    現(xiàn)貨AS-BDEP-214
    現(xiàn)貨AS-BDEP-215
    現(xiàn)貨AS-BDEP-216
    現(xiàn)貨AS-BDEP-217
    現(xiàn)貨AS-BDEP-218
    現(xiàn)貨AS-BDEP-220
    現(xiàn)貨AS-BDEP-254
    現(xiàn)貨AS-BDEP-254C
    現(xiàn)貨AS-BDEP-256
    現(xiàn)貨AS-BDEP-256C
    現(xiàn)貨AS-BDEP-257
    現(xiàn)貨AS-BDEP-257C
    現(xiàn)貨AS-BDEP-297
    現(xiàn)貨AS-BFRQ-204
    現(xiàn)貨AS-470-000
    現(xiàn)貨AS-8534-000
    現(xiàn)貨AS-9370-001
    現(xiàn)貨AS-B351-001
    現(xiàn)貨AS-B352-001
    現(xiàn)貨AS-B801-000
    現(xiàn)貨AS-B802-000
    現(xiàn)貨AS-B802-008
    現(xiàn)貨AS-B803-008
    現(xiàn)貨AS-B804-000
    現(xiàn)貨AS-B804-016
    現(xiàn)貨AS-B804-116
    現(xiàn)貨AS-B805-016
    現(xiàn)貨AS-B806-032
    現(xiàn)貨AS-B807-032
    現(xiàn)貨AS-B807-132
    現(xiàn)貨AS-B808-016
    現(xiàn)貨AS-B809-016
    現(xiàn)貨AS-B814-108
    現(xiàn)貨AS-B817-116
    現(xiàn)貨AS-B821-008
    現(xiàn)貨AS-B821-108
    現(xiàn)貨AS-B824-000
    現(xiàn)貨AS-B824-016
    現(xiàn)貨AS-B825-016
    現(xiàn)貨AS-B826-000
    現(xiàn)貨AS-B826-032
    現(xiàn)貨AS-B826-116
    現(xiàn)貨AS-B827-000
    現(xiàn)貨AS-B827-001
    現(xiàn)貨AS-B827-032
    現(xiàn)貨AS-B828-016
    現(xiàn)貨AS-B829-116
    現(xiàn)貨AS-B832-000
    現(xiàn)貨AS-B832-016
    現(xiàn)貨AS-B833-000
    現(xiàn)貨AS-B833-016
    現(xiàn)貨AS-B836-016
    現(xiàn)貨AS-B837-016
    現(xiàn)貨AS-B838-032
    現(xiàn)貨AS-B840-000
    現(xiàn)貨AS-B840-108
    現(xiàn)貨AS-B846-001
    現(xiàn)貨AS-B846-002
    現(xiàn)貨AS-B855-016
    現(xiàn)貨AS-B862-001
    現(xiàn)貨AS-B863-001
    現(xiàn)貨AS-B863-016
    現(xiàn)貨AS-B864-001
    現(xiàn)貨AS-B865-001
    現(xiàn)貨AS-B872-000
    現(xiàn)貨AS-B872-001
    現(xiàn)貨AS-B872-002
    現(xiàn)貨AS-B872-011
    現(xiàn)貨AS-B872-032
    現(xiàn)貨AS-B872-100
    現(xiàn)貨AS-B872-200
    現(xiàn)貨AS-B873-001
    現(xiàn)貨AS-B873-011
    現(xiàn)貨AS-B875-001
    現(xiàn)貨AS-B875-002
    現(xiàn)貨AS-B875-011
    現(xiàn)貨AS-B875-012
    現(xiàn)貨AS-B875-100
    現(xiàn)貨AS-B875-101
    現(xiàn)貨AS-B875-102
    現(xiàn)貨AS-B875-111
    現(xiàn)貨AS-B875-114
    現(xiàn)貨AS-B875-200
    現(xiàn)貨AS-B882-032
    現(xiàn)貨AS-B882-239
    現(xiàn)貨AS-B883-001
    現(xiàn)貨AS-B883-002
    現(xiàn)貨AS-B883-101
    現(xiàn)貨AS-B883-111
    現(xiàn)貨AS-B883-200
    現(xiàn)貨AS-B883-201
    現(xiàn)貨AS-B884-002
    現(xiàn)貨AS-B885-001
    現(xiàn)貨AS-B885-002
    現(xiàn)貨AS-B885-100
    現(xiàn)貨AS-B885-101
    現(xiàn)貨AS-B885-110
    現(xiàn)貨AS-B885-111
    現(xiàn)貨AS-BADU-201
    現(xiàn)貨AS-BADU-202
    現(xiàn)貨AS-BADU-204
    現(xiàn)貨AS-BADU-205
    現(xiàn)貨AS-BADU-206
    現(xiàn)貨AS-BADU-211
    現(xiàn)貨AS-BADU-212
    現(xiàn)貨AS-BADU-214
    現(xiàn)貨AS-BADU-216
    現(xiàn)貨AS-BADU-254
    現(xiàn)貨AS-BADU-256
    現(xiàn)貨AS-BADU-257
    現(xiàn)貨AS-BCTR-212
    現(xiàn)貨AS-BCTR-214
    現(xiàn)貨AS-BDAO-216
    現(xiàn)貨AS-BDAP-104
    現(xiàn)貨AS-BDAP-112
    現(xiàn)貨AS-BDAP-204
    現(xiàn)貨AS-BDAP-208
    現(xiàn)貨AS-BDAP-209
    現(xiàn)貨AS-BDAP-210
    現(xiàn)貨AS-BDAP-211
    現(xiàn)貨AS-BDAP-212
    現(xiàn)貨AS-BDAP-216
    現(xiàn)貨AS-BDAP-216N
    現(xiàn)貨AS-BDAP-217
    現(xiàn)貨AS-BDAP-218
    現(xiàn)貨AS-BDAP-220
    現(xiàn)貨AS-BDAP-258
    現(xiàn)貨AS-BDAU-104
    現(xiàn)貨AS-BDAU-202
    現(xiàn)貨AS-BDAU-204
    現(xiàn)貨AS-BDAU-205
    現(xiàn)貨AS-BDAU-206
    現(xiàn)貨AS-BDAU-208
    現(xiàn)貨AS-BDAU-252
    現(xiàn)貨AS-BDEO-216
    現(xiàn)貨AS-BDEP-112
    現(xiàn)貨AS-BDEP-208
    現(xiàn)貨AS-BDEP-209
    現(xiàn)貨AS-BDEP-210
    現(xiàn)貨AS-BDEP-211
    現(xiàn)貨AS-BDEP-214
    現(xiàn)貨AS-BDEP-215
    現(xiàn)貨AS-BDEP-216
    現(xiàn)貨AS-BDEP-217
    現(xiàn)貨AS-BDEP-218
    現(xiàn)貨AS-BDEP-220
    現(xiàn)貨AS-BDEP-256
    現(xiàn)貨AS-BDEP-296
    現(xiàn)貨AS-BM85-000
    現(xiàn)貨AS-BMOT-202
    現(xiàn)貨AS-BNUL-200
    現(xiàn)貨AS-BZAE-201
    現(xiàn)貨AS-BZAE-204
    現(xiàn)貨AS-E381-902
    現(xiàn)貨AS-E685-904
    現(xiàn)貨AS-E685-914
    現(xiàn)貨AS-E908-016
    現(xiàn)貨AS-E908-131
    現(xiàn)貨AS-E952-012
    現(xiàn)貨AS-H819-100
    現(xiàn)貨AS-H819-209
    現(xiàn)貨AS-H827-100
    現(xiàn)貨AS-H827-103
    現(xiàn)貨AS-H827-209
    現(xiàn)貨AS-HDTA-200
    現(xiàn)貨AS-HDTA-201
    現(xiàn)貨AS-HDTA-202
    現(xiàn)貨AS-HDTA-212
    現(xiàn)貨AS-J378-000
    現(xiàn)貨AS-J478-000
    現(xiàn)貨AS-J878-000
    現(xiàn)貨AS-J890-000
    現(xiàn)貨AS-J890-001
    現(xiàn)貨AS-J890-002
    現(xiàn)貨AS-J890-101
    現(xiàn)貨AS-J890-102
    現(xiàn)貨AS-J892-101
    現(xiàn)貨AS-J892-101
    現(xiàn)貨AS-J892-102
    現(xiàn)貨AS-M380-004
    現(xiàn)貨AS-M680-116
    現(xiàn)貨AS-MBII-003
    現(xiàn)貨AS-MBKT-005
    現(xiàn)貨AS-MBKT-185
    現(xiàn)貨AS-MEEP-001
    現(xiàn)貨AS-P120-000
    現(xiàn)貨AS-P810-000
    現(xiàn)貨AS-P810-001
    現(xiàn)貨AS-P810-003
在線詢盤(pán)/留言
  • 免責(zé)聲明:以上所展示的信息由企業(yè)自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布企業(yè)負(fù)責(zé),本網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。我們?cè)瓌t 上建議您選擇本網(wǎng)高級(jí)會(huì)員或VIP會(huì)員。
    0571-87774297