3 Molded-Case Circuit Breakers
Replacement Capabilities
Series C 30 mA Ground Fault
(Earth Leakage)
The Series C units (prefix only
listed below) that included a
breaker and integral Earth
Leakage module have been
replaced by the Series G
solution that has the flexibility
to add the Earth Leakage
module in the field. The
Series G solution has an
extended range of 15–630A.
Series C 30 mA Ground
Fault (Earth Leakage)
Note: Please contact Eaton
customer service for assistance
with crossing from the obsolete
product to the new Series G.
Ampere Range—15–400A
Catalog Prefix
Three-Pole Four-Pole
ELFD EL4FD
ELFW EL4FW
ELHMCP EL4HFD
ELHFD EL4HFW
ELHFW EL4HJW
ELHJD EL4HKW
ELHJW EL4JW
ELHKD EL4KW
ELHKW —
ELJD —
ELJW —
ELKD —
ELKW —
Earth Leakage
Ampere
Rating
Series C
Four-Pole
Series G
MCCB
Series G
MCCB
Alt
Series G Earth
Leakage Module
15 EL4FD3015L EGS4015FFG EGC4015FFG ELEBN4125G
20 EL4FD3020L EGS4020FFG EGC4020FFG ELEBN4125G
25 EL4FD3025L EGS4025FFG EGC4025FFG ELEBN4125G
30 EL4FD3030L EGS4030FFG EGC4030FFG ELEBN4125G
35 EL4FD3035L EGS4035FFG EGC4035FFG ELEBN4125G
40 EL4FD3040L EGS4040FFG EGC4040FFG ELEBN4125G
45 EL4FD3045L EGS4045FFG EGC4045FFG ELEBN4125G
50 EL4FD3050L EGS4050FFG EGC4050FFG ELEBN4125G
60 EL4FD3060L EGS4060FFG EGC4060FFG ELEBN4125G
70 EL4FD3070L EGS4070FFG EGC4070FFG ELEBN4125G
80 EL4FD3080L EGS4080FFG EGC4080FFG ELEBN4125G
90 EL4FD3090L EGS4090FFG EGC4090FFG ELEBN4125G
100 EL4FD3100L EGS4100FFG EGC4100FFG ELEBN4125G
110 EL4FD3110L EGS4110FFG EGC4110FFG ELEBN4125G
125 EL4FD3125L EGS4125FFG EGC4125FFG ELEBN4125G
150 EL4FD3150L JGE4150FAG JGC4150FAG ELJBN4150W
50 EL4FW3050JL GES4050AFM — ELEBE4125G
50 EL4FWC3050JL GEC4050AFM — ELEBE4125G
15 EL4HFD3015L EGH4015FFG — ELEBN4125G
20 EL4HFD3020L EGH4020FFG — ELEBN4125G
25 EL4HFD3025L EGH4025FFG — ELEBN4125G
30 EL4HFD3030L EGH4030FFG — ELEBN4125G
35 EL4HFD3035L EGH4035FFG — ELEBN4125G
40 EL4HFD3040L EGH4040FFG — ELEBN4125G
45 EL4HFD3045L EGH4045FFG — ELEBN4125G
50 EL4HFD3050L EGH4050FFG — ELEBN4125G
60 EL4HFD3060L EGH4060FFG — ELEBN4125G
70 EL4HFD3070L EGH4070FFG — ELEBN4125G
80 EL4HFD3080L EGH4080FFG — ELEBN4125G
90 EL4HFD3090L EGH4090FFG — ELEBN4125G
100 EL4HFD3100L EGH4100FFG — ELEBN4125G
110 EL4HFD3110L EGH4110FFG — ELEBN4125G
125 EL4HFD3125L EGH4125FFG — ELEBN4125G
150 EL4HFD3150L JGH3150FAG — ELJBN4150W
Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-65
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Portable Test Kit and Remote
Ground Fault Trip Indicator
Portable Test Kit
Provides verification of
perbance of all frame
sizes of SELTRONIC breakers
while devices are still in
service under varying load
and/or phase unbalance.
The tester operates on
120V, 50/60 Hz, and includes
complete instructions and
test times for testing the long
time, instantaneous operation
and optional ground fault
operation of the breaker.
Portable Test Kit
Remote Ground Fault
Trip Indicator
For use only with SELTRONIC
circuit breakers (LCG, HLCG,
MCG, HMCG, NCG, HNCG,
PCG and PCCG) with built-in
ground fault protection.
Note: UL Listed as a recognized
component.
The SELTRONIC ground fault
indicator is a remoby
mounted device with a
combination indicating light/
reset/test button that will
light when the breaker trips
on a ground fault. Tripping
from overloads or short
circuits will not activate the
device. A separate 120V,
50/60 Hz power source is
required to power the light
and internal relay, which
has 1NO/1NC contacts
for customer connected
alarm, etc. Designed for
panel mounting, it can be
face-mounted by ordering
the optional mounting
bracket below.
Remote Ground
Fault Indicator
Face Mounting Bracket
Face Mounting Bracket for
Ground Fault Indicator
Style Number
STK2
Style Number Catalog Number
1259C14G01 GFAU
Style Number
1264C67G01
V12-T3-66 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Accessories
Rear-Connected Studs
For complete stud assembly,
order a stud and an
appropriate tube based on
thickness of customer’s
mounting panel. A short stud
must be assembled adjacent
to a long stud to maintain
bances required by
Underwriters Laboratories.
400A LA studs of the
same length have sufficient
bance; however, customer
connections may make it
necessary to use a short stud
adjacent to a long stud. Two
studs are required per pole.
Refer to DS29171 Dimension
Sheets for stud sizes and
extensions behind breaker.
For DA, EB, EHB, FB, JA, KA, JB, KB, LB, LBB, HFB, HKA, HKB and HLB Breakers 1
Notes
1 For insulated panels only; two required per pole.
2 Not UL Listed.
3 Included at no charge when ordered with stud.
Mounting Panel
Thickness, Inches
Stud 2 Tube 3
Length Style Number Length Style Number
DA, LB, LBB and HLB Breakers
3/4–1 Short 656D565G03 27/32 313C909H17
3/4–1 Long 656D565G04 3-25/32 313C909H20
1/2–3/4 Short 656D565G03 1-3/32 313C909H18
1/2–3/4 Long 656D565G04 4-1/32 313C909H21
1/4–1/2 Short 656D565G03 1-11/32 313C909H19
1/4–1/2 Long 656D565G04 4-9/32 313C909H22
EB, EHB, FB and HFB (100A Maximum)
1 Short 451D874G01 1-1/16 32B9446H20
1 Long 451D874G02 3-7/16 32B9446H24
1-1/16–15/16 Short 451D874G01 1-3/8 32B9446H21
1-1/16–15/16 Long 451D874G02 3-3/4 32B9446H25
3/8–5/8 Short 451D874G01 1-11/16 32B9446H22
3/8–5/8 Long 451D874G02 4-1/16 32B9446H26
1/4–5/16 Short 451D874G01 2 32B9446H23
1/4–5/16 Long 451D874G02 4-3/8 32B9446H27
FB, HFB 150 Ampere Breakers
1 Short 374D883G01 1-1/16 374D883H06
1 Long 374D883G02 4-5/16 374D883H10
11/16–15/16 Short 374D883G01 1-3/8 374D883H07
11/16–15/16 Long 374D883G02 4-5/8 374D883H11
3/8–5/8 Short 374D883G01 1-11/16 374D883H08
3/8–5/8 Long 374D883G02 4-15/16 374D883H12
1/4–5/16 Short 374D883G01 2 374D883H09
1/4–5/16 Long 374D883G02 5-1/4 374D883H13
JA, KA and HKA Breakers
3/4–1 Short 656D565G01 27/32 456D983H05
3/4–1 Long 656D565G02 3-25/32 456D983H08
1/2–3/4 Short 656D565G01 1-3/32 456D983H06
1/2–3/4 Long 656D565G02 4-1/32 456D983H09
1/4 –1/2 Short 656D565G01 1-11/32 456D983H07
1/4 –1/2 Long 656D565G02 4-9/32 456D983H10
JB, KB and HKB Breakers
3/4–1 Short 5010D23G01 27/32 456D983H05
3/4–1 Long 5010D23G02 3-7/8 5010D23H05
1/2–3/4 Short 5010D23G01 1-3/32 456D983H06
1/2–3/4 Long 5010D23G02 4-1/8 5010D23H06
1/4 –1/2 Short 5010D23G01 1-11/32 456D983H07
1/4 –1/2 Long 5010D23G02 4-3/8 5010D23H07
Rear Connected Stud
Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-67
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
For LAB, LA, MA, HLA, HMA and HNB Breakers 1
Notes
1 For insulated panels only; two required per pole.
2 150, 250, 300 and 400A frames only.
3 This is a special stud that includes six contact nuts for use where bus contact nuts
must be used.
4 600A frames only.
Stud Ampere
Rating
Diameter, Inches
and Thread
Extension Back
of Breaker, Inches
Stud
Style Number
LAB, LA, HLA, LC and HLC Breakers
225 2 1/2–13 3-7/32 1241 345
225 2 1/2–13 6-9/32 1241 346
225 23 1/2–13 4-31/32 1241 392
400 2 3/4–16 5-15/32 5B7383G15
400 2 3/4–16 7-31/32 5B7383G16
400 2 3/4–16 10-15/32 5B7383G17
600 4 1–12 5-29/32 314C960G07
600 4 1–12 5-13/32 314C960G08
600 4 1–12 5-29/32 314C960G09
MA, HMA, MC, HMC, MD and MDS Breakers
225 1/2–13 3-21/32 314C960G01
400 3/4–16 5-29/32 314C960G04
400 3/4–16 8-13/32 314C960G05
400 3/4–16 10-29/32 314C960G06
600 1–12 5-29/32 314C960G07
600 1–12 8-13/32 314C960G08
600 1–12 10-29/32 314C960G09
800 1-1/8–12 5-29/32 314C960G10
800 1-1/8–12 8-13/32 314C960G11
800 1-1/8–12 10-29/32 314C960G12
NB, HNB, NC and HNC Breakers
800 1-1/8–12 5-1/2 623B222G01
800 1-1/8–12 8 623B222G02
800 1-1/8–12 10-1/2 623B222G03
1200 1-1/4–12 5-1/2 373B375G04
1200 1-1/4–12 10-1/2 373B375G03
V12-T3-68 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Panelboard Connecting Straps
For connecting line end of breakers to panelboard bus.
For DA, EB, EHB, FB, JA, KA, JB, KB, LB,
LBB, HFB, HKB and HLB Breakers
For CA, LAB, LA, MA, HLA, HMA and HNB Breakers
Notes
1 Not UL Listed.
2 Bus spacing 2.75 inches in box 5.75 inches deep (600V maximum).
3 Bus spacing 3.50 inches.
Ampere Rating Connector Type 1 Style Number
EB, EHB, FB and HFB Breakers
Narrow Distribution Panelboards 2
50 Center 673B142G02
50 Outside 673B142G09
100 Center 673B142G02
100 Outside 673B142G10
150 Center 673B142G04
150 Outside 673B142G03
Power Panelboards (Convertible) 3
50 Center 1253C72G01
50 Outside 1253C72G03
100 Center 1253C73G03
100 Outside 1253C73G06
150 Center 1253C73G01
150 Outside 1253C73G05
Three-pole mounting bracket 624B600H01
Two-pole mounting bracket 624B600H02
DA, LB, LBB and HLB Breakers 3
400 Center 314C940G04
400 Outside 505C680G01
Mounting bracket (one required) 208B264H01
JA, KA and HKA Breakers 3
225 Center 314C940G03
225 Outside 180C074G01
Mounting bracket (one required) 208B264H01
JB, KB and HKB Breakers 3
250 Center 2600D26G01
250 Outside 2600D26G02
Mounting bracket (one required) 1576707
Panelboard
Connecting Strap Ampere Rating Connector Type 1 Style Number
CA Breaker Power Panelboards (Convertible) 3
225 Center 1253C74G01
225 Outside 1253C74G02
Three-pole mounting bracket 624B624H01
Two-pole mounting bracket 624B624H02
LAB, LA, HLA, LC, HLC 150, 300 and 400A Frames 3
400 Center 32B4570G02
400 Outside 314C541G01
Mounting bracket (two required) 208B297H01
LA, HLA, LC and HLC 600A Frames 3
600 Center 624B609G01
600 Outside 506C052G01
Mounting bracket (two required) 208B297H01
MA, HMA, MC, HMC, MD and MDS Breakers 3
800 Short 314C996G01
800 Medium 314C996G02
800 Long 314C996G03
Mounting bracket (four required) 315C270H01
NB, HNB, NC and HNC Breakers 3
1200 Short 505C606G04
1200 Medium 505C606G05
1200 Long 505C606G06
Mounting bracket (four required) 315C270H01
Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-69
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Plug-In Adapter Kits
For rear-connected applications such as switchboards.
Facilitates ease of installation and front removal of breaker.
Includes conductor for mounting on breaker, plug-in mounting
blocks with matching conductor, rear studs and mounting
hardware. Order two mounting blocks style number when line
and load are required; order one mounting block style number
when either line or load is required.
■Shaded area denotes obsolete or discontinued products
and services. 1
Flat Bus Type
Threaded Studs Type
Mounting Plates
Notes
1 These accessories are no longer available.
2 These plug-in adapter kits are UL Listed as recognized
components.
3 700–1200A adapter kit is front removable, bolt-on design—
not plug-in type.
4 Not UL Listed.
Debion Style Number
EB, EHB, FB Thermal-Magnetic Breakers 2
Flat Bus Type—One Mounting Block, Line or Load
Two-pole, 100A 1480D13G05
Two-pole, 150A 1480D13G05
Three-pole, 100A 1480D13G06
Three-pole, 150A 1480D13G06
FB and HFB Magnetic Only, HFB Thermal-Magnetic 2
Flat Bus Type—One Mounting Block, Line or Load
Two-pole, 100A 1480D13G05
Two-pole, 150A 1480D13G05
Three-pole, 100A 1480D13G06
Three-pole, 150A 1480D13G06
JB, KB, HKB Breakers 1 Flat Bus Type—
Two Mounting Blocks, Line and Load
Two-pole 506C144G17
Three-pole 506C144G18
One Mounting Block, Line Only
Two-pole 1260C86G01
Three-pole 1260C86G02
Two-pole 1260C86G03
Three-pole 1260C86G04
LAB, LA, HLA, LC and HLC (150, 250, 300 and
400A Frame) (Threaded Studs Type)—
Two Mounting Blocks, Line and Load
Two-pole 313C644G25
Three-pole 313C644G26
One Mounting Block, Line or Load
Two-pole 450D010G15
Three-pole 450D010G16
DA, LB, LBB, HLB Breakers 2 Flat Bus Type—
Two Mounting Blocks, Line and Load
Two-pole 313C644G45
Three-pole 313C644G46
One Mounting Block, Line or Load
Two-pole 314C932G03
Three-pole 314C932G04
MA, HMA, MC, HMC, MD and MDS Breakers 3
Threaded Studs—Two Mounting Blocks,
Line and Load
Two-pole, 125–600A 313C644G27
Two-pole, 700–800A 176C544G01 3
Three-pole, 125–600A 313C644G28
Three-pole, 700–800A 176C544G02 3
One Mounting Block, Line or Load
Two-pole, 125–600A 313C370G03
Two-pole, 700–800A 507C049G01 3
Three-pole, 125–600A 313C370G04
Three-pole, 700–800A 507C049G02 3
Flat Bus Type
Debion Style Number
JA, KA and HKA Breakers 4 (Threaded Studs
Type)—Two Mounting Blocks, Line and Load
Two-pole 313C644G29
Three-pole 313C644G30
One Mounting Block, Line or Load
Two-pole 314C932G01
Three-pole 314C932G02
LA, HLA, LC and HLC (600A Frames) 2 (Threaded
Studs)—Two Mounting Blocks, Line and Load
Two-pole 313C644G50
Three-pole 313C644G51
One Mounting Block, Line or Load
Two-pole 506C059G03
Three-pole 506C059G04
One Mounting Block, Line or Load Flat Bus Type
Two-pole 1288C19G01
Three-pole 1288C19G02
MA, HMA, MC, HMC, MD, MDS, NB, HNB, NC, HNC
and NB TRI-PAC Breakers 4 (Flat Bus Type)—
One Mounting Block, Line or Load
MA, HMA, MC, HMC, MD, MDS two-pole 2614D53G05
MA, HMA, MC, HMC, MD, MDS three-pole 2614D53G06
NB, HNB, NC, HNC, NB TRI-PAC two-pole 2614D53G03
NB, HNB, NC, HNC, NB TRI-PAC three-pole 2614D53G04
Debion Style Number
Predrilled panels for:
EB, EHB, FB, HFB 507C047H01
JB, KB 179C207H01
JA, KA 504C823H01
DA, LB, LBB, ALB 178C781H01
LA, LAB, HLA, LC, HLC 504C824H01
MA, HMA, MC, MMC, NB, HNB, NC, HNC 1290C73H01
Threaded Stud Type
V12-T3-70 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Extended Line Terminal Shields
For shielding line side terminal connections. One shield required
per breaker. Order separaby when needed. Sold only in lots of
10, including hardware.
Extended Line Terminal Shields 1
Base Mounting Hardware
No charge when ordered with breaker. Order separaby
when needed.
Base Mounting Hardware
Fuse Mounting Base for PB Breakers
For 2000A non-automatic breakers only.
Fuse Mounting Base for PB Breakers
For use with non-automatic, three-pole circuit breaker. Includes
fuse mounting base and hardware to mount standard Class L
current limiting fuses, 801–2000A (fuses not included).
Note: Interrupters used with fuse mounting base will accept all standard
PB accessories. See Dimension Sheet 29-171 for mounting details.
Breaker Frame Style Number
JB, KB, HKB 1266C07G01
MA, HMA, MC, HMC 208B966G01
NB, HNB, NC, HNC 208B966G02
LAB, LA, (Saf-T-Vue) 314C420G02
JA, KA, LB, LBB (Saf-T-Vue) 314C420G04
LAB, LA, HLA, LC, HLC 314C420G05
DA 314C420G06
JA, KA, HKA, LB, LBB, HLB (standard breaker) 314C420G06
EB, EHB, FB, HFB 625B229G08 2
Debion Style Number
Single-Pole Breakers
EB, EHB, HFB 3 624B375G01
EB, EHB, HFB 4 624B375G02
Two- and Three-Pole Breakers
LAB, LA, HLA, LC, HLC, MA, NB, HMA, HNB, MC 21C6782G05
HMC, NC, HNC 1091716
PB, PC, PCC 624B375G22
DA, JA, KA, HKA, LB, LBB, HLB 21C6782G22
EB, EHB, FB, HFB, MCP 21C6782G18
JB, KB, HKB 673B125G12
CA two-pole 21C6782G28
CA three-pole 21C6782G29
Style Number
6635C78G02 1
Line Terminal Shield
Line Terminal Shield
For complete installation, order:
1. Front-connected, non-automatic PB breaker.
(Order similar to standard front connected, except
omit load conductor extensions.)
2. Fuse mounting base.
3. Fuses (from distributor).
Handle Locks
Non-Padlockable
For prevention of unintentional operation of breaker. Fits over
breaker handle and may be removed.
Padlockable
For prevention of unauthorized operation of breaker. Is nonremovable
once installed on breaker. Meets Underwriters
Laboratories and California Code requirements.
Handle Locks 15
Notes
1 Not UL Listed.
2 One of style 625B229G08 is one package of 10.
3 Individually mounted.
4 Group mounted.
5 All breakers are trip free and will trip with handle locks attached.
Cannot be used when handle extension is used.
Breaker Frame Style Number
Non-Padlockable
FA, EA, CA, EB, EHB, FB, HFB 29B2721H01
LAB, LA, LC, HLC, MA, NB, HLA, HMA, HNB,
MC, HMC, NC, HNC
28B4596G01
GB, GC, GHB, GHC 1294C01H01
DA, JA, KA, HKA, LB, LBB, HLB 29B2721H04
Padlockable
CA 506C438G01
FA, EA, EB, EHB, FB, HFB, MCP150 765A754G01
DA, JA, KA, LB, LBB, HKA, HLB, MCP400 673B796G02
JB, KB, HKB, MCP250 673B796G01
LAB, LA, HLA, LC, HLC 373B591G02
MA, HMA, MC, HMC, MD, MDS 6591C30G02–OFF
MA, HMA, MC, HMC, MD, MDS 6591C30G05–ON/OFF
NB, HNB, NC, HNC 6591C30G01–OFF
NB, HNB, NC, HNC 6591C30G04–ON/OFF
PA, SPCB, PB, Tri-Pac PB, PC 6591C30G03–OFF
Handle Locks
Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-71
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Cable Connectors
The fuse mounting base will accept the following terminals
for front cable connection (omit “T” connectors from rear
connected breakers).
Cable Connectors
Molded Type Handle Extension
For LAB, LA and HLA Breakers 1
For MA, HMA, MC, HMC, NB, HNB, NC and HNC Breakers 1
For PB, PC, PCC and PA/RD Breakers 1
Wire Range, Type Number of Cables Style Number
(3) 3/0–400 kcmil Cu 672B655G01
(4) 400–500 kcmil Cu 180C046G03
Style Number
372B399G01
Style Number
1251C65G01 2
Style Number
6635C78G02 2
Modifications
Only two internally mounted
modifications—shunt trip,
undervoltage release,
auxiliary switch, alarm
switch—may be mounted
in EB through PB. Only one
of these modifications may
be mounted in FB, HFB
magnetic only, two-pole EB,
EHB, FB and SELTRONIC
breakers. None are available
in single-pole breakers except
alarm switch in EB, EHB and
HFB. Contact Avery Creek,
NC, Technical Resource
Center for possible special
combinations of the following
modifications not in
tabulations. Contact factory
for pricing if accessories
are factory installed.
Shunt Trip
For tripping breaker from
a remote point. A solenoid
device mounts within breaker
case. Breaker trips when
coil is energized.
Shunt trips should not be
used as circuit interlocks
using maintained contact
pilot devices.
A cutoff switch breaks the
circuit to the momentary rated
coil when the breaker opens.
Available for control voltages
up to 250 Vdc or 600 Vac.
Voltage and frequency must
be specified. Standard leads
extend 18.00 inches outside
the breaker. Longer leads may
be specified.
Factory-Mounted Shunt Trips
Factory-mounted shunt trips
only can be supplied for the
following breakers: CA, HCA,
CAH, HFB magnetic only
and PB/PBF non-automatic
breakers (molded-case
switches). They are 120 Vac
rated, suitable for 55% pickup
for ground fault application.
Right hand mounting is
standard and they are not
UL Listed.
Notes
1 Not UL listed.
2 Included with frame at no charge.
V12-T3-72 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
■Shaded area denotes obsolete or discontinued products and services. 4
Shunt Trip for Field Mounting 123
Notes
1 120 Vac ratings suitable for 55% pickup for ground fault applications.
2 Not field mountable on non-automatic breakers (molded-case switches).
3 Field mounting voids breakers’ UL listing except on LA, HLA, MA, HMA, NB, HNB, PB, KB, HKB, KA, HKA, LB, HLB and SELTRONIC breakers.
4 These frames are obsolete. For replacement solutions, see the cross-reference on Pages V12-T3-114–V12-T3-168.
5 Available similar to this except “Leads out the load end—(not UL Listed).” Order by debion.
Voltage/Hz
Breaker Type Catalog Number
EB, EHB, FB, HFB 5
(Thermal-Magnetic Only) JB, KB, HKB
JA, KA, HKA, DA,
LB, LBB, HLB LA, LAB, HLA MA, HMA NB, HNB
PB TRI-PAC
and PA
Right-Hand Mounting
600/50–60 Hz 2609D39G15 2609D42G15 2605D15G15 2606D56G15 2606D57G15 2606D58G15 2606D59G15
480/50–60 Hz 2609D39G16 2609D42G16 2605D15G16 2606D56G16 2606D57G16 2606D58G16 2606D59G16
240/50–60 Hz 2609D39G17 2609D42G17 2605D15G17 2606D56G17 2606D57G17 2606D58G17 2606D59G17
208/50–60 Hz 2609D39G18 2609D42G18 2605D15G18 2606D56G18 2606D57G18 2606D58G18 2606D59G18
120/50–60 Hz 2609D39G19 2609D42G19 2605D15G19 2606D56G19 2606D57G19 2606D58G19 2606D59G19
60/50–60 Hz 2609D39G20 2609D42G20 2605D15G20 2606D56G20 2606D57G20 2606D58G20 2606D59G20
48/50–60 Hz 2609D39G21 2609D42G21 2605D15G21 2606D56G21 2606D57G21 2606D58G21 2606D59G21
24/50–60 Hz 2609D39G22 2609D42G22 2605D15G22 2606D56G22 2606D57G22 2606D58G22 2606D59G22
250 DC 2609D39G23 2609D42G23 2605D15G23 2606D56G23 2606D57G23 2606D58G23 2606D59G23
125 DC 2609D39G24 2609D42G24 2605D15G24 2606D56G24 2606D57G24 2606D58G24 2606D59G24
60 DC 2609D39G25 2609D42G25 2605D15G25 2606D56G25 2606D57G25 2606D58G25 2606D59G25
48 DC 2609D39G26 2609D42G26 2605D15G26 2606D56G26 2606D57G26 2606D58G26 2606D59G26
24 DC 2609D39G27 2609D42G27 2605D15G27 2606D56G27 2606D57G27 2606D58G27 2606D59G27
12 DC 2609D39G28 2609D42G28 2605D15G28 2606D56G28 2606D57G28 2606D58G28 2606D59G28
Left-Hand Mounting
600/50–60 Hz 2609D39G01 2609D42G01 2605D15G01 2606D56G01 2606D57G01 2606D58G01 2606D59G01
480/50–60 Hz 2609D39G02 2609D42G02 2605D15G02 2606D56G02 2606D57G02 2606D58G02 2606D59G02
240/50–60 Hz 2609D39G03 2609D42G03 2605D15G03 2606D56G03 2606D57G03 2606D58G03 2606D59G03
208/50–60 Hz 2609D39G04 2609D42G04 2605D15G04 2606D56G04 2606D57G04 2606D58G04 2606D59G04
120/50–60 Hz 2609D39G05 2609D42G05 2605D15G05 2606D56G05 2606D57G05 2606D58G05 2606D59G05
60/50–60 Hz 2609D39G06 2609D42G06 2605D15G06 2606D56G06 2606D57G06 2606D58G06 2606D59G06
48/50–60 Hz 2609D39G07 2609D42G07 2605D15G07 2606D56G07 2606D57G07 2606D58G07 2606D59G07
24/50–60 Hz 2609D39G08 2609D42G08 2605D15G08 2606D56G08 2606D57G08 2606D58G08 2606D59G08
250 DC 2609D39G09 2609D42G09 2605D15G09 2606D56G09 2606D57G09 2606D58G09 2606D59G09
125 DC 2609D39G10 2609D42G10 2605D15G10 2606D56G10 2606D57G10 2606D58G10 2606D59G10
60 DC 2609D39G11 2609D42G11 2605D15G11 2606D56G11 2606D57G11 2606D58G11 2606D59G11
48 DC 2609D39G12 2609D42G12 2605D15G12 2606D56G12 2606D57G12 2606D58G12 2606D59G12
24 DC 2609D39G13 2609D42G13 2605D15G13 2606D56G13 2606D57G13 2606D58G13 2606D59G13
12 DC 2609D39G14 2609D42G14 2605D15G14 2606D56G14 2606D57G14 2606D58G14 2606D59G14
Shunt Trip
Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-73
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Left-Hand Mounting Kits for SELTRONIC Breakers
Left-Hand Mounting Kits for SELTRONIC Breakers
Shunt Trip Coil Data
Notes
1 Rated 48V minimum for ground fault applications.
2 Also available for 24 Vdc. Order by debion.
3 Not for ground fault.
Debion
Breaker
Type
Style
Number
Provision to trip flux transfer shunt trip from
external 32 to 120 Vdc and Vac to 60 Hz source 12
MC, HMC 1371D72G22
NC, HNC 1372D39G13
PC, PCC 1372D35G22
LC, HLC 1371D11G22
Provision to trip flux transfer shunt trip from
external 240 to 600 Vac, 50/60 Hz source 23
MC, HMC 1371D72G32
NC, HNC 1372D39G23
PC, PCC 1372D35G32
LC, HLC 1371D11G32
Shunt Trip
Voltage
Rating
For All Breakers Listed in Previous
Table and on Previous Page
Except CA and SELTRONIC SELTRONIC
Coil Inrush Coil Inrush
Amperes Volt-Amperes Amperes Volt-Amperes
600 AC 0.105 63.0 — —
480 AC 0.085 40.8 — —
240 AC 1.7 408.0 — —
208 AC 1.4 291.2 — —
120 AC 0.88 105.6 15 18
60 AC 9.10 546.0 — —
48 AC 7.50 360.0 — —
24 AC 3.95 94.8 — —
250 DC 2.5 625.0 — —
125 DC 0.975 121.9 — —
60 DC 0.525 31.5 — —
48 DC 1.3 62.4 — —
24 DC (FB) 6 144.0 — —
24 DC (KB) 3.8 91.2 — —
24 DC (others) 8 192 — —
12 DC 6 72 — —
V12-T3-74 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Standard Undervoltage Release
For undervoltage protection.
A solenoid device mounts
within a breaker case. Coil
must be energized before
closing breaker. Trips breaker
when voltage drops below 35
to 70% of coil rating. Picks
up and seals in at 85% of coil
rating. For line voltages
up to 250 Vdc or 600 Vac.
Externally mounted resistors
are supplied for certain
ratings. Standard leads
extend 18.00 inches outside
of breaker. Longer leads may
be specified.
Note: Undervoltage release
attachments are not designed
for, and should not be used as,
circuit interlocks. For further
inbation, Contact Avery
Creek, NC, Technical Resource
Center at 1-800-356-1243.
Factory-Mounted
Undervoltage Releases
All of the above undervoltage
releases can be specified for
factory mounting. Contact
factory for pricing. These
attachments have the leads
out the side and are UL
Listed when factory mounted
unless other non-UL Listed
modifications are used.
Note: Right-hand mounting
is considered standard unless
specified otherwise except JA,
KA, DA, HKA, LB, LBB, HLB
and SELTRONIC available
for left-hand only. JB, KB, HKB
are obsolete.
Factory-mounted
undervoltage releases
only can be supplied for
the following breakers:
● SELTRONIC breakers
(120 Vac, 60 Hz only
standard), MC, HMC, NC,
HNC, PC, PCC, LC, HLC
● SELTRONIC breakers with
remote trip provisions,
MC, HMC 2, NC, HNC 2,
PC, PCC 2, LC, HLC 2
● EB 3, EHB 3, FB 3, HFB 3,
FB 45 and HFB magnetic
only 45
● No UVR available for CA,
CAH and HCA
Undervoltage Release Attachment Kits for Field Mounting 67
Notes
1 Cannot be used with other attachments except a small 1A-1B auxiliary switch rated 250V can be supplied in
right-hand pole.
2 Provided with two leads (total of four) for use with a remote normally open contact (pushbutton, etc.) to trip the
breaker. No external power required.
3 Not available on ambient compensating breakers.
4 Not UL Listed.
5 Right-hand mounting only.
6 Not field mountable on non-automatic breakers (molded-case switches).
7 Field mounting voids UL listing of breaker except on LA, HLA, MA, HMA, NB, HNB, PB, KA, HKA, LB and HLB.
Attachment
Voltage, Hz
Breaker Type
JA, KA, DA, HKA,
LB, LBB, HLB LA, LAB, HLA MA, HMA NB, HNB PB, PA 4
For Right-Hand Mounting
24, 60 — 60A9355G17 — — —
48, 60 — 60A9355G08 — — 5674D29G16
120, 60 — 60A9355G01 457D727G01 373D632G01 5674D29G09
208, 60 — 60A9355G02 457D727G19 373D632G19 5674D29G10
240, 60 — 60A9355G03 457D727G02 373D632G02 5674D29G11
480, 60 — 60A9355G05 457D727G03 373D632G03 5674D29G13
600, 60 — 60A9355G06 457D727G04 373D632G04 5674D29G14
12 DC — 458D020G01 457D727G09 372D032G01 4976D85G01
24 DC — 458D020G02 457D727G10 372D032G02 4976D85G02
48 DC — 458D020G03 457D727G11 372D032G03 4976D85G03
60 DC — 458D020G04 457D727G21 — 4976D85G04
125 DC — 458D020G07 457D727G12 372D032G04 4976D85G07
250 DC — 458D020G08 457D727G13 372D032G05 4976D85G08
For Left-Hand Mounting
48, 60 — 60A9355G16 — — 5674D29G08
120, 60 458D070G01 60A9355G09 457D727G05 373D632G05 5674D29G01
208, 60 458D070G05 60A9355G10 457D727G20 373D632G20 5674D29G02
240, 60 458D070G02 60A9355G11 457D727G06 373D632G06 5674D29G03
480, 60 458D070G03 60A9355G13 457D727G07 373D632G07 5674D29G05
600, 60 458D070G04 60A9355G14 457D727G08 373D632G08 5674D29G06
12 DC 458D070G09 458D020G11 457D727G14 372D032G06 4976D85G11
24 DC 458D070G10 458D020G12 457D727G15 372D032G07 4976D85G12
48 DC 458D070G11 458D020G13 457D727G16 372D032G08 4976D85G13
60 DC — 458D020G14 457D727G22 — 4976D85G14
125 DC 458D070G12 458D020G17 457D727G17 372D032G09 4976D85G17
250 DC 458D070G13 458D020G18 457D727G18 372D032G10 4976D85G18
Standard Undervoltage
Release
Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-75
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Undervoltage Release Coil Data
Voltage
Rating Hz
Breaker Type
EB, EHB, FB, HFB, JB, KB and HKB JA, KA, HKA, DA, LB, LBB and HLB LA, LAB, HLA and PB
Coil
Amperes
External Series
Resistance (Ohms)
Total
VA
Coil
Amperes
External Series
Resistance (Ohms)
Total
VA
Coil
Amperes
External Series
Resistance (Ohms)
Total
VA
600 AC 0.020 25,000 12.0 0.012 50,000 7.2 0.029 20,000 17.4
480 AC 0.016 20,000 7.7 0.013 30,000 6.3 0.014 — 6.8
240 AC 0.021 6000 5.1 0.013 — 3.2 0.036 — 8.7
208 AC 0.019 6000 4.0 0.018 — 3.8 0.036 — 7.5
120 AC 0.023 — 2.8 0.023 — 2.8 0.073 — 8.8
60 AC 0.203 250 12.2 — — — — — —
48 AC 0.245 150 11.8 — — — 0.152 — 7.3
24 AC 0.250 50 6.0 — — — — — —
250 DC 0.026 5000 6.5 0.013 16,500 3.3 0.035 5000 8.8
125 DC 0.026 — 3.3 0.013 6500 1.7 0.039 1500 4.9
60 DC 0.248 200 14.9 0.013 1500 0.8 0.034 — 2.1
48 DC 0.260 150 12.5 0.012 600 0.6 0.040 — 2.0
24 DC 0.141 — 3.4 0.023 — 0.6 0.069 — 1.7
12 DC 0.286 — 3.5 0.048 — 0.6 0.136 — 1.7
MA and HMA NB and HNB MC, HMC, NC, HNC, PC, PCC, LC and HLC
Coil
Amperes
External Series
Resistance (Ohms)
Total
VA
Coil
Amperes
External Series
Resistance (Ohms)
Total
VA
Coil
Amperes
External Series
Resistance (Ohms)
Total
VA
600 AC 0.012 50,000 7.2 0.016 35,000 9.6 — — —
480 AC 0.013 30,000 6.3 0.013 30,000 6.3 — — —
240 AC 0.013 — 3.2 0.013 — 3.2 — — —
208 AC 0.018 — 3.8 0.018 — 3.8 — — —
120 AC 0.023 — 2.8 0.023 — 2.8 0.5 — 6
60 AC — — — — — — — — —
48 AC — — — — — — — — —
24 AC — — — — — — — — —
250 DC 0.013 16,500 3.3 0.013 16,500 3.3 — — —
125 DC 0.013 6500 1.7 0.013 6500 1.7 — — —
60 DC 0.013 1500 0.8 — — — — — —
48 DC 0.012 600 0.6 0.012 600 0.6 — — —
24 DC 0.02 — 0.6 0.023 — 0.6 — — —
12 DC 0.048 — 0.6 0.048 — 0.6 — — —
V12-T3-76 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Alarm Switch
Availability: EB through PC.
For light or alarm indication
when breaker trips. Does
not function with manual
operation. Automatically
resets when breaker is
relatched. Standard leads
extend 18.00 inches outside
of breaker. Longer leads
may be specified. Not
field mountable.
Alarm Switch Contact
Rating (Non-Inductive)
● MC, HMC, LA, LAB, HLA,
LC, HLC: 10A, 120 Vac;
5A, 240 Vac
● EB, EHB, FB, HFB:
5A, 120 Vac
● All other breakers:
10A, 120–240 Vac
Auxiliary Switch
For auxiliary control circuits.
Miniature switches mount
within breaker. Commonly
used for remote indication
of open or closed breaker
and electrically interlocking
component control circuits.
“A” contacts are closed
when breaker is closed.
“B” contacts are open when
breaker is closed. Standard
leads extend 18.00 inches
outside of breaker. Longer
leads may be specified.
Note: Right-hand mounting
standard for EB, EHB, FB, HFB,
JB, KB and HKB. All others are
left-hand mounting as standard
unless otherwise specified.
Factory-Mounted
Auxiliary Switches
All of the above auxiliary
switches can be specified
for factory mounting at the
same price as listed for the
kit. These attachments have
the leads out the side of the
breaker and are UL Listed
when factory mounted
unless other non-UL Listed
modifications are used
(except as noted).
Note: Right-hand mounting
standard for EB, EHB, FB, HFB,
JB, KB and HKB. All others are
left-hand mounting as standard
unless otherwise specified.
Factory-mounted switches
only can be supplied for the
following breaker:
● JB, LBB, LAB, JA, DA, FB l
magnetic only 2m and HFB
magnetic only 2m
Switch Schematic
Alarm Switch
■Shaded area denotes obsolete or discontinued products and services. 9
Auxiliary Switch Attachment Kits for Field Mounting 678
Notes
1 Alarm switches are no longer available
for these frames.?TCSESM083F2CU0,TCSESM083F2CS0,TCSESM063F2CU1,TCSESM083F1CU0
施耐德 莫迪康--MODICON TCSESM083F2CU0 交換機(jī)
TCSESM083F2CS0 交換機(jī)
TCSESM163F2CU0 交換機(jī)
TCSESM163F2CS0 交換機(jī)
TCSESM243F2CU0 交換機(jī)
TCSESM083F1CS0 交換機(jī)
TCSESM083F1CU0 交換機(jī)
TCSESM083F1CS0
TCSESM063F2CU1
TCSESM063F2CS1
TCSESM083F1CU0
499NSS25101
499NSS25102
499NMS25101
499NMS25102
TCSECN300R2
TSXETG1000
TSXETG1010
174CEV20040
TSXETG100
TSXETG3000
TSXETG3010
TSXETG3021
TSXETG3022
TSXETGCF01GI
499NES18100
TCSESM043F2CU0
TCSESM043F1CS0
TCSESM043F2CS0
TCSESM083F23F0
TCSESM083F1CU0
TCSESM083F1CS0
TCSESM163F23F0
TCSESM103F23G0
TCSESM103F2LG0
TCSEAAF1LFS00
TCSEAAF1LFH00
TCSESB083F23F0
TCSESB083F2CU0
TCSESB093F2CU0
TCSESM103F23G0
TCSESM103F2LG0
TCSEAAF1LFS00
TCSEAAF1LFH00
TCSESM083F23F1
TCSESM063F2CU1
TCSESM063F2CS1?特別推薦公司優(yōu)勢(shì)庫(kù)存:
140DAO84210?
140DDI35310?
140MSB10100 1
140DRA84000 60?
140CPU11303 57?
140CPU67160 51?
140BE10000 26?
140DDI35300 22?
140DDI85300 16?
140CPS12400 10?
140CPS11420 9?
140DDO84300 9?
140CPU65160 7?
140CPU43412A 6?
140NOM21100 6?
140CPU65150 5?
140CPU11302 5?
140CPS11410 4?
140CPU53414B 4?
140CRA93200 4?
140CRP93200 4?
140NOE77101 4?
140ARI03010 4?
140ACI03000 3?
140CRP93100 3?
140CRP81100 2?
140DAI55300 2?
140CPS11100 2?
140CPS22400 2?
140CRA93100 2?
140EHC10500 2?
TSXAZY414 2?
140ACI04000 1?
140ACO02000 1?
140AVI03000 1?
140AVO02000 1?
140CHS11000 1?
140CRA21110 1?
140DDO35300 1?
140ESI06210 1?
140NOE77100 1?
140BP01600 1?
PTQ-PDPMV1 140PTQ-PDPMV1 1?
TSXP575634M 1?
TSXPSY5500M 1?
140DAO84000 1?
施耐德莫迪康MODICON昆騰Quantum140PLC常規(guī)件
現(xiàn)貨AS-BADU-205
現(xiàn)貨AS-HDTA-200C
現(xiàn)貨AS-HDTA-201
現(xiàn)貨AS-HDTA-201C
現(xiàn)貨AS-HDTA-202
現(xiàn)貨AS-HDTA-202C
現(xiàn)貨AS-MBKT-085
現(xiàn)貨AS-MBKT-185
現(xiàn)貨AS-MBPL-001
現(xiàn)貨AS-MEEP-000
現(xiàn)貨AS-P120-000
現(xiàn)貨AS-P120-125
現(xiàn)貨AS-WBXT-201
現(xiàn)貨AS-WBXT-203
現(xiàn)貨AS-BADU-206
現(xiàn)貨AS-BADU-210
現(xiàn)貨AS-BADU-211
現(xiàn)貨AS-BADU-212
現(xiàn)貨AS-BADU-214
現(xiàn)貨AS-BADU-216
現(xiàn)貨AS-BADU-254
現(xiàn)貨AS-BADU-254C
現(xiàn)貨AS-BADU-256
現(xiàn)貨AS-BADU-256C
現(xiàn)貨AS-BADU-257
現(xiàn)貨AS-BADU-257C
現(xiàn)貨AS-BBKF-201
現(xiàn)貨AS-BBKF-202
現(xiàn)貨AS-BCTR-205
現(xiàn)貨AS-BCTR-212
現(xiàn)貨AS-BCTR-224
現(xiàn)貨AS-BDA0-216
現(xiàn)貨AS-BDAP-204
現(xiàn)貨AS-BDAP-208
現(xiàn)貨AS-BDAP-210
現(xiàn)貨AS-BDAP-211
現(xiàn)貨AS-BDAP-212
現(xiàn)貨AS-BDAP216N
現(xiàn)貨AS-BDAP-217
現(xiàn)貨AS-BDAP-218
現(xiàn)貨AS-BDAP-220
現(xiàn)貨AS-BDAP-250
現(xiàn)貨AS-BDAP-250C
現(xiàn)貨AS-BDAP-252
現(xiàn)貨AS-BDAP-252C
現(xiàn)貨AS-BDAP-253
現(xiàn)貨AS-BDAP-253C
現(xiàn)貨AS-BDAP-258
現(xiàn)貨AS-BDAP-258C
現(xiàn)貨AS-BDAP-292
現(xiàn)貨AS-BDAU-202
現(xiàn)貨AS-BDAU-208
現(xiàn)貨AS-BDE0-216
現(xiàn)貨AS-BDEA-202
現(xiàn)貨AS-BDEA-203
現(xiàn)貨AS-BDEP-208
現(xiàn)貨AS-BDEP-210
現(xiàn)貨AS-BDEP-211
現(xiàn)貨AS-BDEP-214
現(xiàn)貨AS-BDEP-215
現(xiàn)貨AS-BDEP-216
現(xiàn)貨AS-BDEP-217
現(xiàn)貨AS-BDEP-218
現(xiàn)貨AS-BDEP-220
現(xiàn)貨AS-BDEP-254
現(xiàn)貨AS-BDEP-254C
現(xiàn)貨AS-BDEP-256
現(xiàn)貨AS-BDEP-256C
現(xiàn)貨AS-BDEP-257
現(xiàn)貨AS-BDEP-257C
現(xiàn)貨AS-BDEP-297
現(xiàn)貨AS-BFRQ-204
現(xiàn)貨AS-470-000
現(xiàn)貨AS-8534-000
現(xiàn)貨AS-9370-001
現(xiàn)貨AS-B351-001
現(xiàn)貨AS-B352-001
現(xiàn)貨AS-B801-000
現(xiàn)貨AS-B802-000
現(xiàn)貨AS-B802-008
現(xiàn)貨AS-B803-008
現(xiàn)貨AS-B804-000
現(xiàn)貨AS-B804-016
現(xiàn)貨AS-B804-116
現(xiàn)貨AS-B805-016
現(xiàn)貨AS-B806-032
現(xiàn)貨AS-B807-032
現(xiàn)貨AS-B807-132
現(xiàn)貨AS-B808-016
現(xiàn)貨AS-B809-016
現(xiàn)貨AS-B814-108
現(xiàn)貨AS-B817-116
現(xiàn)貨AS-B821-008
現(xiàn)貨AS-B821-108
現(xiàn)貨AS-B824-000
現(xiàn)貨AS-B824-016
現(xiàn)貨AS-B825-016
現(xiàn)貨AS-B826-000
現(xiàn)貨AS-B826-032
現(xiàn)貨AS-B826-116
現(xiàn)貨AS-B827-000
現(xiàn)貨AS-B827-001
現(xiàn)貨AS-B827-032
現(xiàn)貨AS-B828-016
現(xiàn)貨AS-B829-116
現(xiàn)貨AS-B832-000
現(xiàn)貨AS-B832-016
現(xiàn)貨AS-B833-000
現(xiàn)貨AS-B833-016
現(xiàn)貨AS-B836-016
現(xiàn)貨AS-B837-016
現(xiàn)貨AS-B838-032
現(xiàn)貨AS-B840-000
現(xiàn)貨AS-B840-108
現(xiàn)貨AS-B846-001
現(xiàn)貨AS-B846-002
現(xiàn)貨AS-B855-016
現(xiàn)貨AS-B862-001
現(xiàn)貨AS-B863-001
現(xiàn)貨AS-B863-016
現(xiàn)貨AS-B864-001
現(xiàn)貨AS-B865-001
現(xiàn)貨AS-B872-000
現(xiàn)貨AS-B872-001
現(xiàn)貨AS-B872-002
現(xiàn)貨AS-B872-011
現(xiàn)貨AS-B872-032
現(xiàn)貨AS-B872-100
現(xiàn)貨AS-B872-200
現(xiàn)貨AS-B873-001
現(xiàn)貨AS-B873-011
現(xiàn)貨AS-B875-001
現(xiàn)貨AS-B875-002
現(xiàn)貨AS-B875-011
現(xiàn)貨AS-B875-012
現(xiàn)貨AS-B875-100
現(xiàn)貨AS-B875-101
現(xiàn)貨AS-B875-102
現(xiàn)貨AS-B875-111
現(xiàn)貨AS-B875-114
現(xiàn)貨AS-B875-200
現(xiàn)貨AS-B882-032
現(xiàn)貨AS-B882-239
現(xiàn)貨AS-B883-001
現(xiàn)貨AS-B883-002
現(xiàn)貨AS-B883-101
現(xiàn)貨AS-B883-111
現(xiàn)貨AS-B883-200
現(xiàn)貨AS-B883-201
現(xiàn)貨AS-B884-002
現(xiàn)貨AS-B885-001
現(xiàn)貨AS-B885-002
現(xiàn)貨AS-B885-100
現(xiàn)貨AS-B885-101
現(xiàn)貨AS-B885-110
現(xiàn)貨AS-B885-111
現(xiàn)貨AS-BADU-201
現(xiàn)貨AS-BADU-202
現(xiàn)貨AS-BADU-204
現(xiàn)貨AS-BADU-205
現(xiàn)貨AS-BADU-206
現(xiàn)貨AS-BADU-211
現(xiàn)貨AS-BADU-212
現(xiàn)貨AS-BADU-214
現(xiàn)貨AS-BADU-216
現(xiàn)貨AS-BADU-254
現(xiàn)貨AS-BADU-256
現(xiàn)貨AS-BADU-257
現(xiàn)貨AS-BCTR-212
現(xiàn)貨AS-BCTR-214
現(xiàn)貨AS-BDAO-216
現(xiàn)貨AS-BDAP-104
現(xiàn)貨AS-BDAP-112
現(xiàn)貨AS-BDAP-204
現(xiàn)貨AS-BDAP-208
現(xiàn)貨AS-BDAP-209
現(xiàn)貨AS-BDAP-210
現(xiàn)貨AS-BDAP-211
現(xiàn)貨AS-BDAP-212
現(xiàn)貨AS-BDAP-216
現(xiàn)貨AS-BDAP-216N
現(xiàn)貨AS-BDAP-217
現(xiàn)貨AS-BDAP-218
現(xiàn)貨AS-BDAP-220
現(xiàn)貨AS-BDAP-258
現(xiàn)貨AS-BDAU-104
現(xiàn)貨AS-BDAU-202
現(xiàn)貨AS-BDAU-204
現(xiàn)貨AS-BDAU-205
現(xiàn)貨AS-BDAU-206
現(xiàn)貨AS-BDAU-208
現(xiàn)貨AS-BDAU-252
現(xiàn)貨AS-BDEO-216
現(xiàn)貨AS-BDEP-112
現(xiàn)貨AS-BDEP-208
現(xiàn)貨AS-BDEP-209
現(xiàn)貨AS-BDEP-210
現(xiàn)貨AS-BDEP-211
現(xiàn)貨AS-BDEP-214
現(xiàn)貨AS-BDEP-215
現(xiàn)貨AS-BDEP-216
現(xiàn)貨AS-BDEP-217
現(xiàn)貨AS-BDEP-218
現(xiàn)貨AS-BDEP-220
現(xiàn)貨AS-BDEP-256
現(xiàn)貨AS-BDEP-296
現(xiàn)貨AS-BM85-000
現(xiàn)貨AS-BMOT-202
現(xiàn)貨AS-BNUL-200
現(xiàn)貨AS-BZAE-201
現(xiàn)貨AS-BZAE-204
現(xiàn)貨AS-E381-902
現(xiàn)貨AS-E685-904
現(xiàn)貨AS-E685-914
現(xiàn)貨AS-E908-016
現(xiàn)貨AS-E908-131
現(xiàn)貨AS-E952-012
現(xiàn)貨AS-H819-100
現(xiàn)貨AS-H819-209
現(xiàn)貨AS-H827-100
現(xiàn)貨AS-H827-103
現(xiàn)貨AS-H827-209
現(xiàn)貨AS-HDTA-200
現(xiàn)貨AS-HDTA-201
現(xiàn)貨AS-HDTA-202
現(xiàn)貨AS-HDTA-212
現(xiàn)貨AS-J378-000
現(xiàn)貨AS-J478-000
現(xiàn)貨AS-J878-000
現(xiàn)貨AS-J890-000
現(xiàn)貨AS-J890-001
現(xiàn)貨AS-J890-002
現(xiàn)貨AS-J890-101
現(xiàn)貨AS-J890-102
現(xiàn)貨AS-J892-101
現(xiàn)貨AS-J892-101
現(xiàn)貨AS-J892-102
現(xiàn)貨AS-M380-004
現(xiàn)貨AS-M680-116
現(xiàn)貨AS-MBII-003
現(xiàn)貨AS-MBKT-005
現(xiàn)貨AS-MBKT-185
現(xiàn)貨AS-MEEP-001
現(xiàn)貨AS-P120-000
現(xiàn)貨AS-P810-000
現(xiàn)貨AS-P810-001
現(xiàn)貨AS-P810-003