3 Molded-Case Circuit Breakers
Replacement Capabilities
Types LCG, LCCG, LCGA, LCCGA, MARK 75 HLCG, HLCCG, HLCGA,
HLCCGA SELTRONIC with Built-In Ground Fault Protection
Accessories and Modifications
Field-Mountable Attachments 12345
For CSA, see Page V12-T3-48.
Type LC breakers meet requirements for Class 21a circuit
breakers, and Type HLC meet requirements for Class 23a as
defined by Federal Specification W-C-375b.
UL Listed Interrupting Ratings 8
For all three-phase delta, grounded B phase applications, contact
Avery Creek, NC, Technical Resource Center at 1-800-356-1243.
Additional Accessories and Modifications
Refer to Pages V12-T3-65–V12-T3-79.
Terminals
Note: Order separaby.
Two terminals are required per pole.
Terminals are UL Listed for wire type and range listed below.
When used with aluminum cable, use joint compound.
150, 300 and 400A Frames Only
600A Frame Only
Notes
1 Only one attachment may be mounted per breaker.
2 Contact Avery Creek, NC, Technical Resource Center for other combinations.
3 Molded-case switches do not use standard SELTRONIC attachments, and should be ordered
by debion for factory mounting.
4 Does not void listing of UL Listed breakers.
5 Left pole mounting.
6 Rated 48 volts minimum for ground fault applications requiring tripping at 55% of voltage.
7 Not for use on ground fault applications.
8 Interrupting capacities shown do not apply to molded-case switches.
MARK 75 frame color changed from gray to black in mid-2002.
Debion Style Number
Provision to trip flux transfer shunt trip from external source
32 to 120 Vdc to 60 Hz 6
1371D11G22
240 to 600 Vac, 50/60 Hz 7 1371D11G32
Provision to trip flux transfer shunt trip from external source,
plus a 1A-1B auxiliary switch
32 to 120 Vdc to 60 Hz 6
1371D11G15
240 to 600 Vac, 50/60 Hz 7 1371D11G25
Provision to trip flux transfer shunt trip from 24 Vdc source 1371D93G01
1A-1B auxiliary switch 1371D11G03
24 Vdc shunt trip and 1A-1B auxiliary switch 1371D94G08
Maximum Volts Amperes
Standard Breakers
240 AC 50,000 Asymmetrical, 42,000 Symmetrical
480 AC 35,000 Asymmetrical, 30,000 Symmetrical
600 AC 25,000 Asymmetrical, 22,000 Symmetrical
MARK 75 Breakers
240 AC 75,000 Asymmetrical, 65,000 Symmetrical
480 AC 40,000 Asymmetrical, 35,000 Symmetrical
600 AC 30,000 Asymmetrical, 25,000 Symmetrical
Maximum
Amperes Number of Cables, Wire Range, Type
Catalog
Number
Al/Cu Pressure Terminals
225 (1) #6–350 kcmil Cu, or (1) #4–350 kcmil Al TA225LA1
400 (1) #4–250 kcmil Al/Cu, plus (1) 3/0–600 kcmil Al/Cu TA400LA1
Optional Copper Pressure Terminals
225 (1) #6–350 kcmil Cu T225LA
225 (1) #6–250 kcmil Cu T225LBF
400 (1) #4–250 kcmil Cu, plus (1) 3/0–600 kcmil Cu T401LA
Maximum
Amperes Number of Cables, Wire Range, Type
Catalog
Number
Al/Cu Pressure Terminals
500 (2) 250–350 kcmil Al/Cu TA602LD
600 (2) 400–500 kcmil Al/Cu TA603LA
600 (std.) (2) 250–500 kcmil Al/Cu TA600LA
Optional Copper Pressure Terminals
600 (2) 250–500 kcmil Cu T600LA
V12-T3-52 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Types MC, MCC, MCA, MCCA, MARK 75 Types HMC, HMCC, HMCA, HMCCA SELTRONIC with Solid-State Trip Units 600 Vac, 50/60 Hz
■Shaded area denotes obsolete or discontinued products and services. 1
Breakers for Standard Applications—Frame Only
Breakers for Application at 100% Rating—Frame Only 1
Notes
1 These frames are obsolete. Effective 2/1/02, only the MARK 75 version is available. For replacement solutions, see the cross-reference on
Pages V12-T3-114–V12-T3-167.
2 Two-pole breakers are supplied in three-pole frames with current-carrying parts omitted from center pole.
3 UL Recognized component.
Type MC800 molded-case switch; refer to Page V12-T3-62. MARK 75 frame color changed from gray to black in mid-2002.
Number
of Poles 2
Standard
(Long Delay and Short Time) Short Time Only 3
Long Delay, Short Time and Adjustable
Short Delay Time (0.08 –0.30 seconds)
Catalog Number Catalog Number Catalog Number
Types MC and MCA (400–800A)
2 MC2800F MC2800FM MCA2800F
3 MC3800F MC3800FM MCA3800F
MARK 75 Types HMC and HMCA (400–800A)
2 HMC2800F HMC2800FM HMCA2800F
3 HMC3800F HMC3800FM HMCA3800F
Number
of Poles 2
Standard
(Long Delay and Short Time) Short Time Only 3
Long Delay, Short Time and Adjustable
Short Delay Time (0.08 –0.30 seconds)
Catalog Number Catalog Number Catalog Number
Types MCC and MCCA (400–800A)
3 MCC3800F — MCCA3800F
MARK 75 Types HMCC and HMCCA (400–800A)
3 HMCC3800F — HMCCA3800F
MCA: 600 Vac
Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-53
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Types MCG, MCCG, MCGA, MCCGA and MARK 75 Types HMCG,
HMCCG, HMCGA, HMCCGA SELTRONIC with Built-In Ground
Fault Protection
Complete breaker requires frame and rating plug. See the table
and terminals on Page V12-T3-60. Extra current transber
included for neutral. See accessories on Page V12-T3-65 for
remote ground fault trip indicator.
■Shaded area denotes obsolete or discontinued products
and services. 1
Note: Order two of the desired terminals for each pole of the breaker and
two for the neutral CT. The standard ground fault unit can also be used
without the neutral CT. MARK 75 frame color changed from gray to black
in mid-2002.
Breakers for Standard Applications—Frame Only
Breakers for Application at 100% Rating—Frame Only
Accessories and Modifications
Field-Mountable Attachments 3456
Additional Accessories and Modifications
Refer to Pages V12-T3-65–V12-T3-79.
Rating Plugs
Select from the table on Page V12-T3-60.
For CSA, see Page V12-T3-48.
Type MC SELTRONIC breakers meet requirements for Class 21a,
and MARK 75. Type HMC meet Class 23a as defined by
Federal Spec. W-C-375b.
UL Listed Interrupting Capacity, rms Symmetrical Amperes 9
Terminals
Terminals—Two Terminals Required Per Pole
Notes
1 These frames are obsolete. Effective 2/1/02, only the MARK 75 version is available. For
replacement solutions, see the cross-reference on Pages V12-T3-114–V12-T3-167.
2 For applications other than standard residual scheme, see Application Data 29-160.
3 Does not void listing of UL Listed breakers.
4 Only one of the attachments may be mounted per breaker.
5 For other possible combinations, refer to factory.
6 Molded-case switches do not use standard SELTRONIC attachments and should be ordered
by debion.
7 Rated 48V minimum for ground fault applications requiring tripping at 55% of voltage.
8 Not for ground fault applications.
9 Interrupting capacities shown do not apply to molded-case switches.
j Type Al/Cu pressure terminal.
Also used on breakers with ground fault and on separaby mounted neutral current
transbers. MARK 75 frame color changed from gray to black in mid-2002.
Note: Available without extra CT for neutral. Order by debion as
similar to above except without neutral CT or external CT terminal
connections at same price.
Number
of Poles
Standard
(Long Delay,
Short Time and
Ground Fault Trip)
Long Delay,
Short Time, Adjustable
Short Delay Time and
Ground Fault Trip
Ground Fault
Characteristics
Pickup
Setting
Amperes
Time
Catalog Number Setting
Types MCG and MCGA (400–800A) 2
3 MCG3800F MCGA3800F 80–800 3.5–30 Cy
MARK 75 Types HMCG and HMCGA (400–800A) 2
3 HMCG3800F HMCGA3800F 80–800 3.5-30 Cy
Number
of Poles
Standard
(Long Delay,
Short Time and
Ground Fault Trip)
Long Delay,
Short Time, Adjustable
Short Delay Time and
Ground Fault Trip
Ground Fault
Characteristics
Pickup
Setting
Amperes
Time
Catalog Number Catalog Number Setting
Types MCCG and MCCGA (400–800A) 2
3 MCCG3800F MCCGA3800F 80–800 3.5–30 Cy
MARK 75 Types HMCCG and HMCCGA (400–800A) 2
3 HMCCG3800F HMCCGA3800F 80–800 3.5–30 Cy
Debion Style Number
Provision to trip flux transfer shunt trip from external source
32 to 120 Vdc to 60 Hz 7
1371D72G22
240 to 600 Vac, 50/60 Hz 8 1371D72G32
Provision to trip flux transfer shunt trip from external source,
plus 1a-1b auxiliary switch
32 to 120 Vdc to 60 Hz 7
1371D72G15
240 to 600 Vac, 50/60 Hz 8 1371D72G25
Provision to trip flux transfer shunt trip from external 24 Vdc source 1370D85G01
1A-1B auxiliary switch 1371D72G03
Breaker
AC Volts
240 480 600
MC, MCG 42,000 30,000 22,000
HMC, HMCG 65,000 50,000 25,000
Maximum Amperes Number of Cables, Wire Range, Type Catalog Number
Al/Cu Pressure Terminals
600 (2) #1–500 kcmil TA700MA1 j
800 (std.) (3) 3/0–400 kcmil TA800MA2 j
800 (2) 500–750 kcmil TA801MA j
Optional Copper Pressure Terminals
600 (2) 2/0–500 kcmil T600MA1
800 (3) 3/0–300 kcmil T800MA1
V12-T3-54 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Types NC, NCA, NCG, NCGA, MARK 75 Type HNC, HNCA, HNCG, HNCGA SELTRONIC with Solid-State Trip Units, 600 Vac
Complete breaker requires frame and rating plug. See the table and terminals on Page V12-T3-60. Extra current transber included
for neutral. See accessories on Page V12-T3-65 for remote ground fault trip indicator.
■Shaded area denotes obsolete or discontinued products and services. 1
Type NC, NCA, MARK 75 Type HNC, HNCA SELTRONIC with Solid-State Trip Units, 600 Vac—Frame Only 2
Types NCG, NCGA, and MARK 75 Types HNCG, HNCGA SELTRONIC with Built-In Ground Fault Protection
Complete breaker requires frame and rating plug. See the table and terminals on Page V12-T3-60. Extra current transber included
for neutral. See accessories on Page V12-T3-65 for remote ground fault trip indicator.
Note: The standard ground fault unit above can also be used without the neutral CT. Order two of the desired terminals for each pole of the breaker and
two for the neutral CT.
Types NCG, NCGA and MARK 75 Type HNCG, HNCGA SELTRONIC with Built-In Ground Fault Protection—
Frame Only
Notes
1 These frames are obsolete. Effective 2/1/02, only the MARK 75 version is available. For replacement solutions, see the cross-reference on
Pages V12-T3-114–V12-T3-167.
2 Complete breaker requires frame and rating plug. See the table on Page V12-T3-60. For terminals, see the table on Page V12-T3-55.
3 Two-pole breakers are supplied in three-pole frames with current-carrying parts omitted from center pole.
4 UL Recognized component.
5 For applications other than standard residual scheme, see Application Data 29-160.
Type NC 1200A molded-case switch; refer to Page V12-T3-62. MARK 75 frame color changed from gray to black in mid-2002.
Number
of Poles 3
Standard (Long Delay and Short Time) Short Time Only 4
Long Delay, Short Time and Adjustable
Short Delay Time (0.08 –0.30 Seconds)
Catalog Number Catalog Number Catalog Number
Types NC and NCA (800–1200A)
2 NC21200F NC21200FM NCA21200F
3 NC31200F NC31200FM NCA31200F
Mark 75 Types HNC and HNCA (800–1200A)
2 HNC21200F HNC21200FM HNCA21200F
3 HNC31200F HNC31200FM HNCA31200F
Number
of Poles
Standard (Long Delay, Short Time
and Ground Fault Trip)
Long Delay, Short Time, Adjustable
Short Delay Time, and Ground Fault Trip
Ground Fault Characteristics
Pickup Setting
Catalog Number Catalog Number Amperes Time Setting
Types NCG and NCGA (800–1200A) 5
3 NCG31200F NCGA31200F 120–1200 3.5–30 Cy
MARK 75 Types HNCG and HNCGA (800–1200A) 5
3 HNCG31200F HNCGA31200F 120–1200 3.5–30 Cy
NC: 600 Vac
Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-55
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Types NC, NCA, NCG, NCGA, MARK 75 Type HNC, HNCA, HNCG,
HNCGA SELTRONIC with Solid-State Trip Units, 600 Vac
Accessories and Modifications
Field-Mountable Attachments—Left Handed 12345
For CSA, see Page V12-T3-48.
Type NC SELTRONIC breakers meet requirements for Class 21a,
and MARK 75. Type HNC meet Class 23a as defined by Federal
Spec. W-C-375b.
UL Listed Interrupting Capacity, rms Symmetrical Amperes 8
Rating Plugs
Select from the table on Page V12-T3-60.
Terminals
Note: Two terminals required per pole.
Terminals 9
Additional Accessories and Modifications
Refer to Pages V12-T3-65–V12-T3-79.
Note: MARK 75 frame color changed from gray to black in mid-2002.
Notes
1 For other possible combinations, refer to factory.
2 Molded-case switches do not use standard SELTRONIC attachments and should be ordered
by debion.
3 Does not void listing of UL Listed breakers.
4 Only one of the attachments may be mounted per breaker.
5 Left pole mounting.
6 Rated 48V minimum for ground fault applications requiring tripping at 55% of voltage.
7 Not for ground fault applications.
8 Interrupting capacities shown do not apply to molded-case switches.
9 Also used on breakers with ground fault and on separaby mounted neutral
current transbers.
j Type Al/Cu pressure terminal.
Debion Style Number
Provision to trip flux transfer shunt trip from external source
32 to 120 Vdc to 60 Hz 6 1372D39G13
240 to 600 Vac, 50/60 Hz 7 1372D39G23
Provision to trip flux transfer shunt trip from external source,
plus a 1A-1B auxiliary switch
32 to 120 Vdc to 60 Hz 6 1372D39G16
240 to 600 Vac, 50/60 Hz 7 1372D39G26
Provision to trip flux transfer shunt trip from external 24 Vdc source 1371D94G05
1A-1B auxiliary switch 1371D39G03
24 Vdc shunt trip and 1A-1B auxiliary switch 1371D94G08
Breaker
AC Volts
240 480 600
NC, NCG 42,000 30,000 22,000
HNC, HNCG 65,000 50,000 25,000
Maximum
Amperes
Number of Cables,
Wire Range, Type
Catalog
Number
Al/Cu Pressure Terminals
1000 (3) 3/0–400 kcmil TA1000NB1 j
1200 (std.) (4) 4/0–500 kcmil TA1200NB1 j
1200 (3) 500–750 kcmil TA1201NB1 j
Optional Copper Pressure Terminals
1000 (3) 3/0–500 kcmil T1000NB1
1200 (4) 3/0–400 kcmil T1200NB1
V12-T3-56 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Types PC, PCA, PCC, PCCA 2000, 2500 and 3000A SELTRONIC with Solid-State Trip Units, 600 Vac, 50/60 Hz
Complete breaker requires frame and rating plug. See the table on Page V12-T3-60 and rear connectors (connectors are included in
3000A and all front-connected frames.) Suitable for reverse-feed applications.
■Shaded area denotes obsolete or discontinued products and services. 1
Breakers for Standard Applications—Frame Only
Breakers for Standard Application at 100% Rating—Frame Only
Notes
1 These frames are obsolete. For replacement solutions, see the cross-reference on Pages V12-T3-114–V12-T3-167.
2 Two-pole breakers are supplied in three-pole frames with current carrying parts omitted from center pole.
3 UL Recognized component.
4 UL Listed for standard applications.
5 These breakers are UL Listed for application at 100% of rating per NEC exceptions when used in a properly ventilated and listed enclosure.
Number
of Poles 2
Standard (Long Delay and Short Time) Short Time Only 3
Long Delay, Short Time Trip, and Adjustable
Short Delay Time (0.08 –0.30 seconds)
Catalog Number Catalog Number Catalog Number
Type PC 2000, 1000 to 2000A 4
Rear-Connected Breakers
Type PCA 2000 4
Rear-Connected Breakers
2 PC22000F PC22000FM PCA22000F
3 PC32000F PC32000FM PCA32000F
Front-Connected Breakers Front-Connected Breakers
2 PCF22000F PCF22000FM PCFA22000F
3 PCF32000F PCF32000FM PCFA32000F
Type PC 2500, 1400 to 2500A 4
Rear-Connected Breakers
Type PCA 2500 4
Rear-Connected Breakers
2 PC22500F PC22500FM PCA22500F
3 PC32500F PC32500FM PCA32500F
Front-Connected Breakers Front-Connected Breakers
2 PCF22500F PCF22500FM PCFA22500F
3 PCF32500F PCF32500FM PCFA32500F
Type PC 3000, 1600 to 3000A 4 Type PCA 3000 4
2 PC23000F PC23000FM PCA23000F
3 PC33000F PC33000FM PCA33000F
Number
of Poles 2
Standard (Long Delay and Short Time) Short Time Only 3
Long Delay, Short Time Trip, and Adjustable
Short Delay Time (0.08 –0.30 seconds)
Catalog Number Catalog Number Catalog Number
Type PCC 2000, 1000 to 2000A 5—Rear-Connected Breakers
2 PCC22000F PCC22000FM PCCA22000F
3 PCC32000F PCC32000FM PCCA32000F
Front Connected Breakers
2 PCCF22000F PCCF22000FM PCCFA22000F
3 PCCF32000F PCCF32000FM PCCFA32000F
Type PCC 2500, 1400 to 2500A 5—Rear-Connected Breakers
2 PCC22500F PCC22500FM PCCA22500F
3 PCC32500F PCC32500FM PCCA32500F
Front-Connected Breakers
2 PCCF22500F PCCF22500FM PCCFA22500F
3 PCCF32500F PCCF32500FM PCCFA32500F
Type PC 3000, 1600 to 3000A 5
2 PCC23000F PCC23000FM PCCA23000F
3 PCC33000F PCC33000FM PCCA33000F
PC: 600 Vac
Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-57
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Accessories and
Modifications
Drawout Mounting Breakers,
Three-Pole Only
Breaker frame and complete
drawout frame with safety
tripping interlock.
Order by debion.
Secondary contacts supplied
as required at no extra
charge. Order required rating
plug separaby. Refer to
Page V12-T3-79.
Note: Includes breakers without
adjustable short delay time.
Rating Plugs
Select from the table on
Page V12-T3-60.
Stationary portion of drawout
frame only for future breaker
installations, three-pole only.
Refer to Page V12-T3-79.
Special Type PCC Breakers for
SCR Power Supplies
These drawout mounting
breakers are designed with
a 2 to 4 times magnetic trip
adjustment and special time
delay trip characteristics to
provide maximum protection
and coordination with SCR
power supplies on offshore
drilling rigs. Suitable for
application at 100% of rating.
Order by debion.
Secondary contacts supplied
as required. Order standard
rating plugs separaby.
Availability: PCC2000,
PCC2500 drawout-mounting
breakers.
Type PC and PCC meet
requirements of Class 25a
as defined in Federal Spec.
W-C-375b.
For CSA, see
Page V12-T3-48.
UL Listed Interrupting Capacity rms Symmetrical Amperes
(Standard and Ground Fault Breakers) 1
Note
1 Interrupting capacities shown do not apply to molded-case switches.
Additional Accessories
and Modifications
Refer to Pages V12-T3-65–
V12-T3-79.
Breaker
AC Volts
240 480 600
PC, PCC 125,000 100,000 100,000
V12-T3-58 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Types PCG, PCGA, PCCG,
PCCGA SELTRONIC with
Built-In Ground Fault
Protection Includes Extra
Current Transber for
Neutral (Optional Remote
Ground Fault Trip Indicator
Kit, Page V12-T3-65)
Complete breaker requires
frame and rating plug. See the
table on Page V12-T3-60 and
rear connectors (except frontconnected
frames and 3000A
frames include connectors).
■Shaded area denotes
obsolete or discontinued
products and services.
Note: The standard ground fault
unit listed can also be used
without the neutral CT.
Note: Available without
extra CT for neutral. Order
by debion as similar to
above except without neutral
CT or external CT terminal
connections at same price.
Older catalog numbers:
PCFGX—”X” means without
fourth CT.
Breakers for Standard Application—Frame Only
Breakers for Application at 100% Rating—Frame Only
Notes
1 UL Listed for standard applications.
2 For application other than standard residual schemes, refer to Application Data 29-160.
3 These breakers are UL Listed for application at 100% of rating per NEC exceptions when used in a properly ventilated and listed enclosure.
Number
of Poles
Standard (Long Delay,
Short Time and Ground Fault Trip)
Long Delay, Short Time, Ground Fault
Trip, and Adjustable Short Delay Time
(0.08 –0.30 Seconds)
Ground Fault Characteristics
Pickup
Setting
Time
Catalog Number Catalog Number Setting
Type PCG 2000 12—Rear-Connected Breakers Type PCGA 2000 12 1000 to 2000A 2—Rear-Connected Breakers
3 PCG32000F PCGA32000F 200–1200 3.5–30 cycles
Front-Connected Breakers
3 PCFG32000F PCFGA32000F 200–1200 3.5–30 cycles
Type PCG 2500 12—Rear-Connected Breakers Type PCGA 2500 12 1400 to 2500A 2—Rear-Connected Breakers
3 PCG32500F PCGA32500F 240–1200 3.5–30 cycles
Front-Connected Breakers
3 PCFG32500F PCFGA32500F 240–1200 3.5–30 cycles
Type PCG 3000 12 Type PCGA 3000 12 1600 to 3000A 2
3 PCG33000F PCGA33000F 300–1200 3.5–30 cycles
Number
of Poles
Standard (Long Delay,
Short Time and Ground Fault Trip)
Long Delay, Short Time, Ground Fault
Trip, and Adjustable Short Delay Time
(0.08 –0.30 Seconds)
Ground Fault
Characteristics
Pickup
Setting
Time
Catalog Number Catalog Number Setting
Type PCCG 2000 3—Rear-Connected Breakers Type PCCGA 2000 3 1000 to 2000A 2—Rear-Connected Breakers
3 PCCG32000F PCCGA32000F 200–1200 3.5–30 cycles
Front-Connected Breakers
3 PCCFG32000F PCCFGA32000F 200–1200 3.5–30 cycles
Type PCCG 2500 3—Rear-Connected Breakers Type PCCGA 2500 3 1400 to 2500A 2—Rear-Connected Breakers
3 PCCG32500F PCCGA32500F 240–1200 3.5–30 cycles
Front-Connected Breakers
3 PCCFG32500F PCCFGA32500F 240–1200 3.5–30 cycles
Type PCCG 3000 3 Type PCCGA 3000 3 1600 to 3000A 2
3 PCCG33000F PCCGA33000F 300–1200 3.5–30 cycles
Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-59
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Types PCG, PCGA, PCCG, PCCGA SELTRONIC with Built-In
Ground Fault Protection Accessories and Modifications
PC breakers are not UL Listed.
Field-Mountable Attachments 123
Rear Bus Connectors
Two required per pole. Fixed mounting breakers.
Rear Bus Connectors
Racking Crank for
Drawout Frames
To engage or withdraw
the moving portion of
the drawout. A standard
0.50-inch hex socket with
extension can be used for
this purpose.
Racking Crank
Cell Switches Mounted on
Drawout Frames, All Ratings
A maximum of four switches
can be provided. Order by
debion. Each switch
provides a NO and NC
contact that transfers before
reaching the test b
when being withdrawn, and
after the test b when
being racked in.
Approximate Shipping Weights, PC and PCC Breakers
(Three-Pole)
Debion Style Number
Provision to trip flux transfer shunt trip from external source
32 to 120 Vdc to 60 Hz 4
1372D35G22
240 to 600 Vac, 50/60 Hz 5 1372D35G32
Provision to trip flux transfer shunt trip from external source
plus 1A-1B auxiliary switch
32 to 120 Vdc to 60 Hz 4
1372D35G15
240 to 600 Vac, 50/60 Hz 5 1372D35G25
2A-2B auxiliary switch 1372D35G18
Provision to trip flux transfer shunt trip from external 24 Vdc source 1371D95G01
1A-1B auxiliary switch 1372D35G03
1A-1B auxiliary switch and 24 Vdc shunt trip 1371D95G04
2A-2B auxiliary switch and 24 Vdc shunt trip 1371D95G07
3A-3B auxiliary switch and 24 Vdc shunt trip 1371D95G10
Breaker Frame 6 Connector Style/Catalog Number
PC2000 7, PCC2000 7 BA2000PB
PC2500 7, PCC2500 7 BA2500PB
PC3000, PCC3000 Included in frame
Style Number
765A767G01
Rating
Breaker
PC, PCC PCF, PCCF PCG, PCCG PCFG, PCCFG
2000 136 lbs 163 lbs 160 lbs 185 lbs
2500 145 lbs 175 lbs 170 lbs 200 lbs
3000 220 lbs — 245 lbs —
Busbar Connections
Busbar Connections—“T” Connector
(For Cu/AI Bus)
Two required per pole. For rear bus connection of breakers
through 2000A. Accepts up to four bus bolts. May be rotated 90°.
Note: Shipped separaby from breaker.
“C” Connector (For Cu/AI Bus)
Two required per pole. For rear bus connection of
2500A breakers.
Cable Connector
Fits “T” Connector and 2000A front-connected breakers.
Accepts four 400–600 kcmil copper cables.
Notes
1 For other possible combinations, contact your local Eaton Field Sales office.
2 Only one of these attachments may be mounted per breaker.
3 Left pole mounting.
4 Rated 48V minimum for ground fault applications.
5 Not for ground fault applications.
6 Also apply to equivalent ratings of PCG and PCCG ground fault breakers.
7 Not required for front-connected frames.
Catalog Number
BA2000PB
Breaker Amperes Catalog Number
2500 BA2500PB
Catalog Number
505C706G04
“T” Connector
“C” Connector
Cable Connector
V12-T3-60 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
SELTRONIC Rating Plug Selection Data
Rating plugs listed below are for both standard breakers and breakers with built-in ground fault protection.
Rating Plug Selection Data
Notes
1 Ampere rating when used in short time only frames:
LC-150: 150A MC-800: 800A PC-3000: 3000A
LC-300: 300A NC-1200: 1200A LCL-250: 250A
LC-400: 400A PC-2000: 2000A LCL-400: 400A
LC-600: 600A PC-2500: 2500A
2 Magnetic trip range of adjustable rating plugs:
LC, HLC, MC, HMC: 3 to 10 times ampere setting
NC, HNC, PC, PCC, LCL-400: 2 to 8 times ampere setting
LCL-250: 3 to 9 times ampere setting
3 Adjustable 70 to 100% except as noted.
4 Adjustable 75 to 100%.
5 Adjustable 50 to 100%.
6 Adjustable 80 to 100%.
Contact Avery Creek, NC, Technical Resource Center for old style (three prong) ground fault
rating plugs.
Rating Plugs Only (For Two- or Three-Pole Frames)
Continuous
Ampere
Rating 1
Magnetic Trip
Setting, Amperes
Fixed
Rating Plugs
Adjustable
Rating Plugs 23
Low High Catalog Number Catalog Number
For 150A Frames: LC, LCA, LCG, LCGA, HLC, HLCA, HLCG, HLCGA
75 225 750 1LC75 —
90 270 900 1LC90 —
100 300 1000 1LC100 A1LC100 4
125 375 1250 1LC125 A1LC125
150 450 1500 1LC150 A1LC150 5
For 300A Frames: LC, LCA, LCG, LCGA, HLC, HLCA, HLCA, HLCG, HLCGA
150 450 1500 3LC150 —
175 525 1750 3LC175 —
200 600 2000 3LC200 —
225 675 2250 3LC225 A3LC225
250 750 2500 3LC250 A3LC250
275 825 2750 3LC275 A3LC275
300 900 3000 3LC300 A3LC300 5
For 400A Frames: LC, LCA, LCG, LCGA, HLC, HLCA, HLCG, HLCGA
200 600 2000 4LC200 —
225 675 2250 4LC225 —
250 750 2500 4LC250 —
300 900 3000 4LC300 A4LC300
350 1050 3500 4LC350 A4LC350
400 1200 4000 4LC400 A4LC400 5
For 600A Frames: LC, LCA, LCG, LCGA, HLC, HLCA, HLCG, HLCGA, LCC,
LCCA, HLCC, HLCCA, LCCG, LCCGA, HLCCG, HLCCGA
300 900 3000 6LC300 —
350 1050 3500 6LC350 —
400 1200 4000 6LC400 A6LC400 4
450 1350 4500 6LC450 A6LC450
500 1500 5000 6LC500 A6LC500
600 1800 6000 6LC600 A6LC600 5
For 800A Frames: MC, MCA, MCG, MCGA, HMC, HMCA, HMCG, HMCGA,
MCC, MCCA, HMCC, HMCCA, MCCG, MCCGA, HMCCG, HMCCGA, MDS
400 1200 4000 8MC400 —
500 1500 5000 8MC500 A8MC500 6
600 1800 6000 8MC600 A8MC600
700 2100 7000 8MC700 A8MC700
800 2400 8000 8MC800 A8MC800 5
Rating Plugs Only (For Two- or Three-Pole Frames)
Continuous
Ampere
Rating 1
Magnetic Trip
Setting, Amperes
Fixed
Rating Plugs
Adjustable
Rating Plugs 23
Low High Catalog Number Catalog Number
For 1200A Frames: NC, NCA, NCG, NCGA, HNC, HNCA, HNCG, HNCGA
800 1600 6400 12NC800 A12NC800 4
900 1800 7200 12NC900 A12NC900
1000 2000 8000 12NC1000 A12NC1000
1200 2400 9600 12NC1200 A12NC1200 5
For 2000A Frames: PC, PCA, PCC, PCCA, PCG, PCGA, PCCG, PCCGA
1000 2000 8000 20PC1000 —
1200 2400 9600 20PC1200 —
1400 2800 11,200 20PC1400 —
1600 3200 12,800 20PC1600 A20PC1600
1800 3600 14,400 20PC1800 A20PC1800
2000 4000 16,000 20PC2000 A20PC2000 5
For 2500A Frames: PC, PCA, PCC, PCCA, PCG, PCGA, PCCG, PCCGA
1400 2800 11,200 25PC1400 —
1600 3200 12,800 25PC1600 —
1800 3600 14,400 25PC1800 A25PC1800
2000 4000 16,000 25PC2000 A25PC2000
2500 5000 20,000 25PC2500 A25PC2500 5
For 3000A Frames: PC, PCA, PCC, PCCA, PCG, PCGA, PCCG, PCCGA
1600 3200 12,800 30PC1600 —
1800 3600 14,400 30PC1800 —
2000 4000 16,000 30PC2000 —
2500 5000 20,000 30PC2500 A30PC2500
3000 6000 24,000 30PC3000 A30PC3000 5
Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-61
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Molded-Case Switches
Molded-case switches are UL Listed devices and are available
only as high magnetic trip type with fixed trip setting.
■Shaded area denotes obsolete or discontinued
products and services. 1
Molded-Case Switches with High Magnetic Trip
(Fixed Trip Setting)
Molded-Case Switch Terminal Data
Molded-Case Switches with High Magnetic Trip—
Trip Setting and Tolerance
Notes
1 These frames are obsolete. For replacement solutions, see the cross-reference
on Pages V12-T3-114–V12-T3-167.
2 Catalog number suffix identification:
K = Molded-case switch with high magnetic trip (fixed trip setting)
S = Saf-T-Vue cover
L = With line and load terminals
W = No terminals
3 Molded-case switch dimensions are the same as the equivalent thermal-magnetic breaker.
Refer to Dimension Sheet 29-171.
Number
of Poles
Maximum
Volts
Maximum
Amperes
Switch
Catalog Number 23
2 240 400 DA2400WK
3 240 400 DA3400WK
1 120 100 EB1100LK
2 240 100 EB2100LK
3 240 100 EB3100LK
3 240 100 EB3100SLK
1 277 100 EHB1100LK
2 480 100 EHB2100LK
3 480 100 EHB3100LK
3 480 100 EHB3100SLK
2 600 100 FB2100LK
2 600 150 FB2150LK
3 600 100 FB3100LK
3 600 150 FB3150LK
3 600 150 FB3150SLK
4 277/480 100 FB4100LK
4 277/480 150 FB4150LK
2 600 225 JA2225WK
2 600 225 JA2225WSK
3 600 225 JA3225WK
3 600 225 JA3225WSK
2 600 250 JB2250WK
2 600 250 JB2250WSK
3 600 250 JB3250WK
3 600 250 JB3250WSK
2 600 225 KA2225WK
2 600 225 KA2225WSK
3 600 225 KA3225WK
3 600 225 KA3225WSK
2 600 250 KB2250WK
2 600 250 KB2250WSK
3 600 250 KB3250WK
3 600 250 KB3250WSK
2 600 400 LB2400WK
2 600 400 LB2400WSK
3 600 400 LB3400WK
3 600 400 LB3400WSK
2 600 400 LBB2400WK
2 600 400 LBB2400WSK
3 600 400 LBB3400WK
3 600 400 LBB3400WSK
MCS
Type
Maximum
Switch
Amperes
Wire
Type
Number
of Wires
Wire
Range
Terminal Type
or Catalog
Number
Standard Terminals
DA, LB, LBB 400 Cu only 2 3/0–250 kcmil T400DA2
EB, EHB, FB 100 Cu 1 #14–1/0 Pressure
FB 150 Cu/Al 1 #4–4/0 Pressure
JA, KA 225 Cu/Al 1 #4–350 kcmil TA225LA1
JB, KB
250
Cu/Al 1 #4–350 kcmil TA250KB
Optional Terminals
DA, LB, LBB 400 — — — —
EB, EHB, FB 100 Cu/Al 1 #4–4/0 Pressure
FB 150 — — — —
JA, KA 225 Cu 1 #6–350 kcmil T225LA
JB, KB 250 Cu 1 #4–350 kcmil T250KB
Frame Rating
Trip Setting
(Amperes)
Tolerance
(%)
EB 100 1000 ±20
EHB/FB 100 1200 ±20
FB 150 1500 ±20
DA/LB/LBB 400 4000 +10
– 0
JA/KA 225 2250 +10
– 0
JB/KB 250 2500 +10
– 0
V12-T3-62 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
■Shaded area denotes obsolete or discontinued products and services. 1
Molded-Case Switches with High Magnetic Trip
(Fixed Trip Setting)
Molded-Case Switch Terminal Data
Molded-Case Switches With High Magnetic Trip—
Trip Setting and Tolerance
Notes
1 These frames are obsolete. For replacement solutions, see the cross-reference
on Pages V12-T3-114–V12-T3-167.
2 Catalog number suffix identification:
K = Molded-case switch with high magnetic trip (fixed trip setting)
S = Saf-T-Vue cover
W = No terminals
3 Molded-case switch dimensions are the same as the equivalent thermal-magnetic breaker.
Refer to Dimension Sheet 29-171.
4 For molded-case switch types LC, LCC—use LA attachments;
MC and MCC—use MA attachments; NC—use NB attachments.
5 For molded-case switch types PC, PCC and PCF, rating plug is included and use SELTRONIC
PC attachments.
Number
of Poles
Maximum
Volts
Maximum
Amperes
Switch
Catalog Number 23
2 240 225 CA2225KW
3 240 225 CA3225KW
2 600 400 LA2400WK
2 600 400 LA2400WSK
2 600 600 LA2600WK
2 600 600 LA2600WSK
3 600 400 LA3400WK
3 600 400 LA3400WSK
3 600 400 LA3600WK
3 600 400 LA3600WSK
2 600 400 LAB2400WK
2 600 400 LAB2400WSK
3 600 400 LAB3400WK
3 600 400 LAB3400WSK
2 600 600 LC2600WK 4
3 600 600 LC3600WK 4
2 600 600 LCC2600WK 4
3 600 600 LCC3600WK 4
2 600 800 MA2800WK
2 600 800 MA2800WSK
3 600 800 MA3800WK
3 600 800 MA3800WSK
2 600 800 MC2800WK 4
3 600 800 MC3800WK 4
2 600 800 MCC2800WK 4
3 600 800 MCC3800WK 4
2 600 1200 NB21200WK
2 600 1200 NB21200WSK
3 600 1200 NB31200WK
3 600 1200 NB31200WSK
2 600 1200 NC21200WK 4
3 600 1200 NC31200WK 4
2 600 2000 PB22000WK
2 600 2500 PB22500WK
3 600 2000 PB32000WK
3 600 2500 PB32500WK
2 600 2000 PBF22000K
3 600 2000 PBF32000WK
2 5 600 2000 PC22000WK
2 5 600 2500 PC22500WK
2 5 600 3000 PC23000K
3 5 600 2000 PC32000WK
3 5 600 2500 PC32500WK
3 5 600 3000 PC33000K
2 5 600 2000 PCC22000WK
2 5 600 2500 PCC22500WK
2 5 600 3000 PCC23000K
3 5 600 2000 PCC32000WK
3 5 600 2500 PCC32500WK
3 5 600 3000 PCC33000K
2 5 600 2000 PCF22000K
3 5 600 2000 PCF32000K
MCS
Type
Maximum
Switch
Amperes
Wire
Range
Wire
Type
Number
of Wires
Terminal
Type or
Catalog
Number
Standard Terminals (Aluminum Body)
CA 225 #1–300 kcmil Cu/Al 1 TA225CA2
LA400, LAB 400 #4–250 kcmil,
plus 3/0–600 kcmil
Cu/Al 1 TA400LA1
LA600, LC600 600 250/500 kcmil Cu/Al 2 TA600LA
MC, MA 800 3/0–400 kcmil Cu/Al 3 TA800MA2
NC, NB 1200 4/0–500 kcmil Cu/Al 4 TA1200NB1
NC, NB 1200 — — — —
PC2000, PCC2000 2000 BA2000PB rear bus connector
PC2500, PCC2500 2500 BA2500PB rear bus connector
PC3000, PCC3000 3000 Rear bus connector included in frame
Optional Terminals
CA 225 — — — —
LA400, LAB 400 #4–250 kcmil,
plus 3/0–600 kcmil
Cu 1 T401LA
LA600, LC600 600 250/500 kcmil Cu 2 T600LA
MC, MA 800 3/0–300 kcmil Cu 3 T800MA1
NC, NB 1200 3/0–400 kcmil Cu 4 T1200NB1
NC, NB 1200 500–750 kcmil Cu/Al 3 TA1201NB1
PC2000, PCC2000 2000 BA2000PB rear bus connector
PC2500, PCC2500 2500 BA2500PB rear bus connector
PC3000, PCC3000 3000 Rear bus connector included in frame
Frame Rating
Trip Setting
(Amperes)
Tolerance
(%)
CA 225 2250 +20
–10
LA (400) 400 4000 +10
– 0
LA/LC 600 6000 +10
– 0
MA/MC 800 8000 +10
– 0
NB/NC 1200 12,000 +10
– 0
PB/PC 2000–3000 12,000 +10
– 0
Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com V12-T3-63
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Type MCP Motor
Circuit Protector
The motor circuit protector
(MCP) is designed specifically
for the protection of motor
circuits. It operates on the
magnetic principle with a
current sensing coil in each of
the three poles, with the trippoint
adjustable from the front.
MCPs are the fastest devices
available for bing low level
faults and offer circuit breaker
features and convenience—
resettable, quick-make
quick-break, deadfront
and protection against
single phasing.
MCPs are rated to correspond
to NEMA starter size.
Current Limiter Attachment
The EL current limiter is an
attachment that bolts to
the load end of the MCP to
provide increased interrupting
capacity. The combination is
UL Listed as a recognized
component for application at
up to 200,000A symmetrical
at 600 Vac. It is coordinated
with the MCP so that normal
short circuits will be bed
automatically by the MCP,
opening all three poles, and
only the rare high fault will
cause the limiter to function.
Current limiters must be
applied as shown in the
terminal table above.
Note: Sizes 0–4 only.
Terminals
Terminals are included
with both the MCP and the
current limiter. Standard
terminals are aluminum alloy,
with non-aluminum terminals
optional for use with only
the MCP. Both standard
and optional terminals will
accommodate aluminum
or copper conductors.
Note: Except 400A Size 5.
Non-aluminum terminal suitable
for copper only.
When using aluminum
conductors, use of joint
compound is recommended.
Wire ranges are listed in the
terminal table above.
Terminals
Motor Circuit Protectors
■Shaded area denotes obsolete or discontinued products
and services. 1
UL Listed
The MCP is UL Listed as a
recognized component and
requires additional listing by
the control manufacturer in
combination with a contactor
and overload relay.
Modifications for MCP
These modifications must be
factory installed. Consult
factory for pricing.
Modifications for MCP 3
Accessories for MCP
For handle mechanisms
refer to Pages V12-T3-95–
V12-T3-112.
Note: On 400A Size 5, an external
resistor is supplied for voltages,
above 240 Vac and 24 Vdc.
Accessories for MCP
Current Limiters
Interrupting Ratings
Maximum application current
shall be determined by testing
the MCP in combination with
a contactor and overload relay.
Additional capacity can be
obtained by using the current
limiter attachment.
Base Mounting Hardware
No charge when ordered
with MCP. Order separaby
when required.
Base Mounting Hardware
Notes
1 These frames are obsolete. For
replacement solutions, see the crossreference
on Pages V12-T3-114–
V12-T3-167.
2 Catalog numbers ending in CR were
previously listed ending in RC. This
is a catalog number change only, not
a material change.
3 Not UL Listed.
4 Mounts only in right pole; only one
Modification marked can be used in
MCP (Sizes 0–4).
5 On 400A Size 5, an external resistor is
supplied for voltages above 240 Vac
and 24 Vdc.
6 On Sizes 0–4 and 250A Size 5, an
external resistor is supplied for customer
mounting, except for 120 Vac, 12, 24,
125 Vdc.
7 Also applicable to MCPs with
optional terminals.
MCP or Limiter
(Amperes)
Terminals
Standard Aluminum Optional Non-Aluminum
Size 0, 1, 2 #14–#4 #14–1/0
Size 3 #6–3/0 #14–1/0
Size 4 #4–4/0 #4–4/0
Size 5 (250) #4–350 kcmil #4–350 kcmil
Size 5 (400) — (2) 3/0–250 kcmil
Limiters to 50 #14–#2 —
Limiters to 100 #1–4/0 —
Limiters to 150 #1–4/0 —
Starter
Size
Trip
Range,
Amperes
Continuous
Ampere
Rating
With Standard Aluminum
Alloy Terminals
Catalog Number
With Optional
Non-Aluminum Terminals 2
Catalog Number
0 7–22 3 MCP0322R MCP0322CR
0 18–58 7 MCP0358R MCP0358CR
0 50–150 15 MCP03150R MCP03150CR
1 100–300 30 MCP13300R MCP13300CR
2 160–480 50 MCP23480R MCP23480CR
3 275–1000 100 MCP331000R MCP331000CR
4 450–1550 150 MCP431550R MCP431550CR
4 575–1800 150 MCP431800R MCP431800CR
5 1250–2500 250 MCP532500 MCP532500C
5 2000–4000 400 — MCP534000C
Sizes 0–4 MCP with
Current Limiter
Size 5 MCP 532500
Debion
Auxiliary switches 4—1A and 1B,
2As and 2Bs
Shunt trip 4
Undervoltage release 456
Moisture-fungus treatment
For
MCP Size
Use
Accessories For
Sizes 0–4 FB
5 (250A) KB
5 (400A) LB
Limiter Catalog
Numbers
For MCP Catalog
Numbers 7
EL3003R MCP0322R
EL3007R MCP0358R
EL3015R MCP03150R
EL3030R MCP13300R
EL3050R MCP23480R
EL3100R MCP331000R
EL3150R MCP431550R
EL3150R MCP431800R
Debion Style Number
Sizes 0–4 21C6782G18
Size 5 (250A) 673B125G12
Size 5 (400A) 21C6782G22
V12-T3-64 Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions CA08100014E—October 2016 www.eaton.com
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
3 Molded-Case Circuit Breakers
Replacement Capabilities
Series C 30 mA Ground Fault
(Earth Leakage)
The Series C units (prefix only
listed below) that included a
breaker and integral Earth
Leakage module have been