国产精品久久久久久久久,四季AV一区二区夜夜嗨,日韩精品无码中文字幕电影,www.五月婷婷.com

產(chǎn)品簡介
MPM-A1652F-MJ72AA觸摸屏現(xiàn)貨
產(chǎn)品價(jià)格:¥640.00元/件
上架日期:2020-07-09
發(fā)貨地:福建 廈門市
供應(yīng)數(shù)量:不限
最少起訂:1件
瀏覽量:258
詳細(xì)說明
    詳細(xì)參數(shù)
    品牌其他型號(hào)MPM-A1652F-MJ72AA
    加工定制

    MPM-A1652F-MJ72AA


    尊敬的客戶您好!相遇,是一個(gè)多么動(dòng)人的名詞。于這茫茫人海中,于這網(wǎng)海茫茫中,每天有多少的相遇擦肩而過,每天又有多少的匆匆擦肩而過。緣分,讓你我相遇。期待您的來電!珍惜這得來不易的緣。



    聯(lián)系人:鄭阿清
    手 機(jī):18106937709(微信同號(hào))
    QQ: 3007272972




    主營品牌:AB、ABB、GE、施耐德、本特利、西屋、英維斯、HIMA等

    ◆我們售出的產(chǎn)品都經(jīng)過專 業(yè)測 試認(rèn) 證

    ◆互惠互利,共創(chuàng)雙贏! 


       

              廈門興銳嘉進(jìn)出口有限公司坐落于美麗的鷺島——廈門?。?! 

    廈門興銳嘉進(jìn)出口有限公司連接到的服務(wù)

    從當(dāng)天交貨到采購解決方案,找到一系列有用的服務(wù)來提高生產(chǎn)率,節(jié)省您的時(shí)間和金錢。

     

    獲得所需的支持,以使您的采購流程盡可能高效。我們經(jīng)驗(yàn)豐富的團(tuán)隊(duì)將在這里幫助您整合備品備件,消除復(fù)雜性并減少流程中的時(shí)間浪費(fèi)。






    MPM-A2152F-SJ72AA


    Signal ground: the ground of an b signal element-sensor; the ground of an AC power supply; the ground of an n wire, usually where the main noise is generated; the ground of an enclosure or wire Mesh, usually to prevent electrostatic or magnetic induction, it is connected to the earth by a special copper wire. Protective Ground: generally ground the outer shell of the machine or the independent device inside the machine to protect the personal safety and protect the equipment from electric leakage. The above several kinds of situations have not solved well can choose the suitable isolator product to solve the common ground interference problem. 4.2 earthing of DCS: There are two types of "earthing" in computer control systems. One is the enclosure and shielding of the equipment, which is usually connected to the earth. The purpose of earthing is to avoid the electric charge of the casing which affects the safety of personnel and equipment, and to keep the electric potential between the casing and the shielding layer and the earth so as to shield the external electromagnetic interference. The other is the reference status of the power source or signal. In microcomputer control system, there are analog signal, digital signal, and power (DC) voltage ground terminal. The ground of these signals is ultimaby the ground of the DC power supply. In order to prevent the interference caused by the common impedance, "bus bar separate wiring" is adopted, that is, analog and digital are separated in the circuit, bus bar separate wiring is adopted, and finally two ground are connected together at one point. The Shield layer of the signal adopts the principle of single-point grounding, which can prevent the potential difference (UCM) between different grounding points from bing a current loop through the shield layer and causing interference. Different types of DCS system have different requirements for grounding, but in the final analysis it is to meet the requirements of "a little grounding" . Finally, only one point of the whole grounding system is connected to the grounding grid and meets the requirements of the grounding resistance. The grounding requirement of DCS system should be definite, complete and complete, and can not be changed to meet the different requirements of users. In the power plant environment, DCS is required to have strong anti-interference ability, and the users expect the grounding mode and grounding resistance to be relaxed. But only strictly according to the requirements of manufacturers to implement system grounding, to ensure the system stable operation, but also to facilitate the early exclusion of some fault grounding factors. Following to XX Power Plant Control System (Symphony) ground as an example for analysis: This project does not set a separate DCS ground system, Symphony system of the process control cabinet through the grounding cable in series, the final point is connected to the electrical grounding grid by a single point at the power supply cabinet, and the grounding point within a radius of 5 meters is the one without large current and voltage starting and stopping equipment. The power supply cables from the power supply to the distribution panel and from the distribution panel to the module cabinet shall use 3-core cables as the fire wire, the middle wire and the ground wire respectively. The Middle Wire and the ground wire shall be shorted at the power outlet, connect this short contact to the nearest reliable building grounding system using a flat grounded copper cable (see note 2) , otherwise the center and ground wires should not be shorted anywhere else. When using two-way power supply, it is best to ground the two power supply at the same point.

    VPL-B0633T-CJ12AA
    VPL-B0633M-PK14AS
    VPL-B0633M-PK14AA
    VPL-B0633M-PK12AA
    VPL-B0633M-PJ14AA
    VPL-B0633M-PJ12AA
    VPL-B0633M-CK14AA
    VPL-B0633M-CK12AA
    VPL-B0633M-CJ14AA
    2711P-T19C22D9P-B
    2711P-T19C22D9P
    2711P-T19C22A9P-B
    2711P-T19C22A9P
    2711P-T15C4D9
    2711P-T15C4D8TP
    2711P-T15C4D8
    2711P-T15C4A9
    2711P-T15C4A8


    MPM-A1652F-MJ72AA

    MPM-A1652F-MJ72AA

在線詢盤/留言
  • 免責(zé)聲明:以上所展示的信息由企業(yè)自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布企業(yè)負(fù)責(zé),本網(wǎng)對(duì)此不承擔(dān)任何保證責(zé)任。我們?cè)瓌t 上建議您選擇本網(wǎng)高級(jí)會(huì)員或VIP會(huì)員。
    0571-87774297