詳細參數(shù) | |||
---|---|---|---|
品牌 | 西門子 | 型號 | 6ES7288-2DT32-0AA0 |
結構形式 | 其他 | 安裝方式 | 現(xiàn)場安裝 |
LD指令處理器 | 軟PLC | 加工定制 | 否 |
西門子EM DT32模塊6ES7288-2DT32-0AA0
西門子EM DT32模塊6ES7288-2DT32-0AA0
潯之漫智控技術上海有限公司(西門子系統(tǒng)集成商)專業(yè)銷售西門子S7-200/300/400/1200PLC、
數(shù)控系統(tǒng)、變頻器、人機界面、觸摸屏、伺服、電機、西門子電纜等,
并可提供西門子維修服務,歡迎來電垂詢
SIPLUS extreme products are based on SIMATIC standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme specific inbation was added.
The modules are used centrally with SIMATIC S7-31xF-2 DP and in the ET 200M distributed I/O device together with SIMATIC IM151-7 F-CPU, S7-31xF-2 DP, S7-416F-2 and S7-400F/FH.
0 - 20 mA and 4 - 20 mA current transmitters (also HART) can be connected as encoders.
The analog b module converts analog signals from the process to digital signals for internal processing by the fail-safe SIMATIC S7 CPUs.
The safety functions required for fail-safe operation are integrated in the module.
The following functions are available:
Article number |
6AG1336-4GE00-2AB0 |
|
---|---|---|
|
SIPLUS S7-300 SM336 F 6AI 15BIT |
|
Supply voltage |
|
|
Rated value (DC) |
24 V; ±5 % |
|
Reverse polarity protection |
Yes |
|
Input current |
|
|
From power supply L+, typ. |
150 mA |
|
from backplane bus 5 V DC, max. |
90 mA |
|
Power loss |
|
|
Power loss, typ. |
4.5 W |
|
Analog bs |
|
|
Number of analog bs |
6 |
|
permissible b current for current b (destruction limit), max. |
40 mA |
|
Input ranges |
|
|
|
No |
|
|
Yes |
|
|
No |
|
|
No |
|
|
No |
|
Input ranges (rated values), currents |
|
|
|
Yes |
|
|
150 ?; typ. 150 ohms max. 175 ohms |
|
|
Yes |
|
|
150 ?; typ. 150 ohms max. 175 ohms |
|
Cable length |
|
|
|
1 000 m |
|
Analog value generation for the bs |
|
|
Integration and conversion time/resolution per channel |
|
|
|
16 bit; 15 bit + sign |
|
|
20 ms @ 50 Hz, 16.7 ms @ 60 Hz |
|
|
f=n x (f1 ±0.5 %) |
|
Encoder |
|
|
Connection of signal encoders |
|
|
|
Yes |
|
|
Yes |
|
Errors/accuracies |
|
|
Operational error limit in overall temperature range |
|
|
|
0.3 %; 60 μA |
|
Basic error limit (operational limit at 25 °C) |
|
|
|
0.1 %; 20 μA |
|
Interrupts/diagnostics/status inbation |
|
|
Diagnostics function |
Yes |
|
Alarms |
|
|
|
Yes |
|
Diagnoses |
|
|
|
Yes |
|
Diagnostics indication LED |
|
|
|
Yes |
|
|
Yes |
|
|
No |
|
Potential separation |
|
|
Potential separation analog bs |
|
|
|
Yes |
|
|
Yes |
|
|
Yes |
|
Isolation |
|
|
Isolation tested with |
370V for 1 min |
|
Standards, approvals, certificates |
|
|
CE mark |
Yes |
|
Highest safety class achievable in safety mode |
|
|
|
4 |
|
|
e |
|
|
SIL 3 |
|
Ambient conditions |
|
|
Ambient temperature during operation |
|
|
|
-25 °C; = Tmin; Startup @ -25 °C |
|
|
60 °C; = T max; *+70 °C when forced convection at a minimum air speed of 0.3 m/s through the modules is ensured. If in the course of maintenance or automatic diagnosis it is determined that the admissible specified beters have been exceeded, the modules should be subjected to a proof test (function check) by the manufacturer. |
|
Ambient temperature during storage/transportation |
|
|
|
-40 °C |
|
|
70 °C |
|
Altitude during operation relating to sea level |
|
|
|
2 000 m |
|
|
Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) |
|
Relative humidity |
|
|
|
100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
|
Resistance |
|
|
Use in stationary industrial systems |
|
|
|
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
|
|
Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
|
|
Yes; Class 3S4 incl. sand, dust, * |
|
Use on ships/at sea |
|
|
|
Yes; Class 6B2 mold and fungal spores (excluding fauna); Class 6B3 on request |
|
|
Yes; Class 6C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
|
|
Yes; Class 6S3 incl. sand, dust; * |
|
Usage in industrial process technology |
|
|
|
Yes; Class 3 (excluding trichlorethylene) |
|
|
Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) |
|
Remark |
|
|
|
* The supplied plug covers must remain in place over the unused interfaces during operation! |
|
connection b / header |
|
|
required front connector |
20-pin |
|
Dimensions |
|
|
Width |
40 mm |
|
Height |
125 mm |
|
Depth |
120 mm |
|
Weights |
|
|
Weight, approx. |
350 g |
西門子EM DT32模塊6ES7288-2DT32-0AA0 西門子EM DT32模塊6ES7288-2DT32-0AA0