6AV6381-2BE07-5AV0
6AV6381-2BE07-5AV0
4xI 0/3xV
The line differential protection SIPROTEC 7SD80 has been conceived for selective line protection of power cables and overhead lines up to 24km for all kind of starpoint configurations. The implemented phase comparison algorithm is a fast and stable b for line protection in industry and distribution grids. The protection interface communication is carried out directly without external equipment over copper wires, optical fibers or both in redundancy. The wide scope of non directional and directional functions can be applied miscellaneously as emergency functions as well as backup functions. For instance, the SIPROTEC 7SD80 enables simplified and cost saving concepts for meshed grids and busbar protection by means of reverse interlocking.
Features
Fast and selective tripping is guaranteed even if the communication fails between the relays. The scope of functions includes protection functions as well as functions for control and monitoring. The interoperable connectivity to substation control systems is give by standard protocols like IEC 61850.
The general concept of redundance for protection and its communication gets completed by Ethernet redundancy protocols (PRP, HSR, RSTP) and thus increases the total system availability. Integrated functions for commissioning help and easy settings lead to short commissioning times.
Hardware
Product homepage - downloads from the internet (catalogs, certificates, firmware, manuals,...)
The SIPROTEC 7SD80 is a numerical line differential protection relay, which in addition to its main function, the selective protection of overhead lines and cables, also covers control and monitoring tasks.
Line protection
SIPROTEC 7SD80 devices are suitable as selective line protection for application in high-voltage and medium-voltage systems of all types of neutral designs (solid, low-resistance or high-resistance earthed, isolated or compensated). Apart from the main protection function, the line differential protection, SIPROTEC 7SD80 offers a lot of additional protection functions. These can be used in parallel as a backup protection function, or as an emergency function if the main protection function fails, and they complement the range of functions of 7SD80 for application in transmission lines.
Control
The integrated control function permits control of disconnect devices, grounding switches or circuit-breakers through the integrated operator panel, binary bs, DIGSI 4 or the control or automation system (e.g. SICAM).
Programmable logic
The integrated logic characteristics (CFC) allow the user to add own functions for automation of switchgear (e.g. interlocking) or switching sequence. The user can also generate user-defi ned messages. This functionality can b the base to create extremely flexible transfer schemes.
Operational measured values
Extensive measured values (e.g. I, V), metered values (e.g. Wp, Wq) and limit values (e.g. for voltage, frequency) provide improved system management as well as simplification by the commissioning As for the operational measured values, a special focus was placed on the measured values critical for differential protection. So, the attenuation values and the signal-to-noise ratio of the communication connection, for example, are acquired and indicated in addition to the measurement of the quality of the begram exchange per time unit. Particular attention was paid to making the commissioning of the differential protection easier and safer. In this context, the amplitude and angle of the currents and of the voltages, if applicable, are displayed additionally with reference to the local measuring variable. In this way, a possible incorrect connection (polarity reversal) of the current transbers can be detected and eliminated early enough.
Operational indication
Monitoring of operation is ensured and documented by storage of event logs, trip logs, fault records and statistics.
Protection functions
Control functions /programmable logic
Monitoring functions
Communication interface