詳細參數(shù) | |||
---|---|---|---|
品牌 | 西門子 | 型號 | 6ES7307-1KA02-0AA0 |
結構形式 | 模塊式 | 安裝方式 | 現(xiàn)場安裝 |
LD指令處理器 | 其他 | 加工定制 | 否 |
西門子模塊代理商|宿州西門子模塊代理商
西門子模塊代理商|宿州西門子模塊代理商
ULTRAMAT 23 是一種創(chuàng)新型多組分分析儀,可利用 NDIR 原理測量最多三種對紅外線敏感的氣體。紫外分光光度計可用來測量濃度很低的 SO2 和 NO2。
通過使用電化學氧傳感器或按照順磁測量原理(“啞鈴型”)工作的測量槽,也可以測量氧氣 (O2)。使用附加的電化學 H2S 測量槽時,可以在沼氣應用中進行測量。
使用 ULTRAMAT 23 氣體分析儀,最多可連續(xù)測量 4 種氣體組分。該裝置可配有以下傳感器:
Application areas in biogas plants
Application area of bagnetic oxygen sensor
Separate gas paths
The ULTRAMAT 23 with 2 IR components without pump is also available with two separate gas paths. This allows the measurement of two measuring points as used e.g. for the NOx measurement before and after the NOx converter.
The ULTRAMAT 23 gas analyzer can be used in emission measuring devices and for process and safety monitoring.
Versions conbing to EN 14181 and EN 15267
According to EN 14181, which is standardized in the EU and required in many European countries, a QAL1 qualification test, i.e. certification of the complete measuring device including gas paths and conditioning, is required for continuous emission monitoring systems (CEMS). In accordance with EN 15267, this must be perbed by an independent accredited authority. In Germany, for example, the test is perbed by the German Technical Inspectorate (TüV) and the test report is bted to the Federal/State Workgroup for Emission Control (Bund/L?nder-Arbeitsgemeinschaft für Immissionsschutz - LAI) for examination/approval. Notification is then issued by the German Federal Environment Agency (Umweltbundesamt - UBA) in the Federal Gazette (Bundesanzeiger) as well as by the German Technical Inspectorate (TüV) here: https://www.qal1.de/en.
In the UK, the QAL1 test reports are prepared by Sira Environmental of the Environmental Agency in accordance with the MCERTS scheme and bted for approval and publication on the SIRA Environmental websites. The other European countries rely either on the German or English certification scheme.
For use in EN 14181 applications, the devices with the article numbers 7MB235X in the Set CEM CERT (7MB1957) have undergone qualification testing according to German standards of EN 15267. These German Technical Inspectorate (TüV) versions of the ULTRAMAT are suitable for measurement of CO, NO, SO2 and O2 according to sections 13 and 27 of the BlmSchV (Federal Emission Law of Germany) and TA Luft. Smallest measuring range tested and approved by the German Technical Inspectorate:
1 and 2-component analyzer
3-component analyzer
Also tested as additional measuring ranges in accordance with EN 15267-3:
Determination of the analyzer drift according to EN 14181 (QAL3) can be carried out manually or also with a PC using the SIPROM GA maintenance and servicing software. In addition, selected manufacturers of emission buation computers offer the possibility to read the drift data via the analyzer's serial interface and automatically record and process it in the buation computer.
Version with faster response time
The connection between the two condensation traps is equipped with a stopper to lead the complete flow through the measuring cell (otherwise only 1/3 of the flow), i.e. the response time is 2/3 faster. The functions of all other components remain unchanged.
Chopper purge
Consumption 100 ml/min (upstream pressure setting: approx. 3 000 hPa).
RS 485 present in basic unit (connection from the rear).
Options
ULTRAMAT 23, membrane keyboard and graphic display
ULTRAMAT 23, design
Designs – parts wetted by sample gas |
|||
---|---|---|---|
Gas path |
19" rack unit |
Desktop unit |
|
With hoses |
Condensation trap/gas inlet |
- |
PA (polyamide) |
Condensation trap |
- |
PE (polyethylene) |
|
Gas connections 6 mm |
PA (polyamide) |
PA (polyamide) |
|
Gas connections ?" |
Stainless steel, mat. no. 1.4571 |
Stainless steel, mat. no. 1.4571 |
|
Hose |
FPM (Viton) |
FPM (Viton) |
|
Pressure switch |
FPM (Viton) + PA6-3-T (Trogamide) |
FPM (Viton) + PA6-3-T (Trogamide) |
|
Flowmeter |
PDM/Duran glass/X10CrNiTi1810 |
PDM/Duran glass/X10CrNiTi1810 |
|
Angle units/T-pieces |
PA6 |
PA6 |
|
Internal pump, option |
PVDF/PTFE/EPDM/FPM/Trolene/stainless steel, mat. no. 1.4571 |
PVDF/PTFE/EPDM/FPM/Trolene/stainless steel, mat. no. 1.4571 |
|
Solenoid valve |
FPM70/Ultramide/stainless steel, mat. no. 1.4310/1.4305 |
FPM70/Ultramide/stainless steel, mat. no. 1.4310/1.4305 |
|
Safety condensation trap |
PA66/NBR/PA6 |
PA66/NBR/PA6 |
|
Analyzer chamber |
|||
|
Aluminum |
Aluminum |
|
|
Aluminum |
Aluminum, black anodized |
|
|
Stainless steel, black anodized, mat. no. 1.4571 |
Stainless steel, mat. no. 1.4571 |
|
|
CaF2, quartz |
CaF2 |
|
|
E353 |
E353 |
|
|
FPM (Viton) |
FPM (Viton) |
|
With pipes, only available in version "without pump" |
Gas connections 6 mm/?" |
Stainless steel, mat. no. 1.4571 |
- |
Pipes |
Stainless steel, mat. no. 1.4571 |
- |
|
Analyzer chamber |
- |
||
|
Aluminum |
- |
|
|
Aluminum |
- |
|
|
Stainless steel, mat. no. 1.4571 |
- |
|
|
CaF2 |
- |
|
|
E353 |
- |
|
|
FPM (Viton) |
- |
ULTRAMAT 23, portable, in sheet-steel housing with internal sample gas pump, condensation trap with safety filter on front plate, optional oxygen measurement
ULTRAMAT 23, 19" rack-mounted enclosure with internal sample gas pump; optional oxygen measurement
ULTRAMAT 23, 19" rack-mounted enclosure without internal sample gas pump; optional oxygen measurement
ULTRAMAT 23, 19" rack unit housing without internal sample gas pump, with separate gas path for the 2nd measured component or for the 2nd and 3rd measured component, optional oxygen measurement
ULTRAMAT 23, 19" rack-mounted enclosure, sample gas path version in pipes, separate gas path, always without sample gas pump, without safety filter and without safety condensation trap
ULTRAMAT 23, 19" rack-mounted enclosure with internal sample gas pump and H2S sensor
ULTRAMAT 23, 19" rack-mounted enclosure with internal sample gas pump and bagnetic oxygen measurement
ULTRAMAT 23, 19" rack unit enclosure with IR detector, UV photometer (UV module); optional oxygen measurement
ULTRAMAT 23, 19" rack-mounted enclosure with UV photometer (UV module); optional oxygen measurement