現(xiàn)貨全新原裝6ES7416-2XP07-0AB0 S7-400 CPU416-2
SIMATIC S7-400,CPU 416-2, 中央處理器,帶: 內(nèi)存 8 MB, (4 MB 代碼,4 MB 數(shù)據(jù)), 1. 接口 MPI/DP 12 MBIT/S, 第 2 個 PROFIBUS DP 接口.
西門子代理商現(xiàn)貨供應
現(xiàn)貨供應
上海斌勤電氣技術有限公司
發(fā)布人:康奎 (銷售經(jīng)理)發(fā)布
本公司簽約正式的銷售合同,并開具13%的增-值-稅-發(fā)-票。
外地客戶統(tǒng)一采用快遞發(fā)貨,也支持上門提貨,貨物快遞到您手時候,一定要開箱檢驗!如有損壞,請拒絕簽收,并由快遞公司返回!
在你簽收后表示你對該貨物沒有異議!我們會給予您檢測時間,并請在貨物到給予確認,謝謝合作!
產(chǎn)品均為密封包裝,外包裝詳見產(chǎn)品圖片,白色標簽上均有產(chǎn)品訂貨號和產(chǎn)地,各位買家在收到貨后,請核對型號,無誤后再拆包裝、
本公司宗旨:本著以誠信為本,以顧客為中心.質(zhì)量保證·服務誠信·價格實惠.
為用戶提供專業(yè)的自動化產(chǎn)品及服務!
相關西門子產(chǎn)品技術:
CPU 416
訂貨數(shù)據(jù) 附件 產(chǎn)品信息 組態(tài)工具
跳轉到
概述
應用
設計
功能
技術規(guī)范
更多信息
概述
高端性能范圍內(nèi)的高性能 CPU
適用于對性能要求很高的工廠
CPU 416-3 PN/DP 中集成了 PROFINET 功能
應用
CPU 416-2, CPU 416-3 and CPU 416-3 PN/DP are powerful SIMATIC S7-400 CPUs.
The integrated PROFIBUS DP interfaces in the CPU 416-2 and CPU 416-3 make it possible to connect directly to the PROFIBUS DP fieldbus as a master or slave.
An additional DP master system can be connected to the CPU 416-3 and CPU 416-3 PN/DP using the IF 964-DP interface module.
The integrated PROFINET interface of the CPU 416-3 PN/DP includes switch functionality when the ERTEC 400-ASIC is used. This forms the basis for providing two externally accessible PROFINET ports. In addition to hierarchical network topologies, this also enables the creation of line structures in the new S7-400 controllers.
Note:
Only the 6ES7 964-2AA04-0AB0 interface submodule may be used.
設計
Both CPUs are equipped with the following:
Powerful processor:
The CPUs achieve instruction execution times as low as 0.03 μs per binary instruction.
CPU 416-2: 5.6 MB RAM (of which 2.8 MB each for program and data);
CPU 416-3: 11.2 MB RAM (of which 5.6 MB each for program and data);
CPU 416-3 PN/DP: 11.2 MB RAM (of which 5.6 MB each for program and data);
fast RAM for parts of the user program relevant to execution.
Flexible expansion:
Up to 262144 digital and 16384 analog inputs/outputs.
Multi-point interface MPI:
With the MPI it is possible to establish simple networking of max. 32 stations at a data transmission rate of up to 12 Mbit/s. The CPUs can establish up to 44 connections to stations of the communications bus (C bus) and the MPI.
Mode selector switch:
Designed as toggle switch.
Diagnostics buffer:
The last 120 fault and interrupt events are retained in a ring buffer for diagnostic purposes. The number of entries can be parameterized.
Real-time clock:
The date and time are appended to diagnostic messages of the CPU.
Memory card:
For expansion of the integrated load memory. RAM and FEPROM cards (FEPROM for retentive storage) are available
Combined MPI/DP interface and integrated PROFIBUS DP interface (CPU 416-2 and CPU 416-3):
The PROFIBUS DP master interface allows a distributed automation configuration offering high speed and ease of use. From the user's point of view, the distributed I/O is treated as central I/O (same configuring, addressing and programming).
Mixed configuration: SIMATIC S5 and SIMATIC S7 as PROFIBUS master according to EN 50170.
CPU 416-3 and CPU 416-3 PN/DP also include:
A module slot:
An additional PROFIBUS DP master system can be connected via the IF 964-DP interface module.
CPU 416-3 PN/DP additionally includes:
PROFINET interface with 2 ports (switch):
PROFINET I/O, 256 IO devices connectable
PROFINET CBA
功能
Block protection:
A password concept protects the user program from unauthorized access.
Integral HMI services:
The user only has to specify the source and destination of the data with HMI devices. The data are then transported cyclically and automatically by the system.
Integrated communications functions:
PG/OP communication
Shared data communication
S7 standard communication
S7 communication
Firmware update using network
CPU 416-3 PN/DP additional:
Open communication over TCP/IP, UDP and ISO-on-TCP (RFC1006)
Distributed intelligence in Component Based Automation (CBA) on PROFINET
Additional diagnostic options with integrated web server
Parameterizable attributes
The STEP 7 tool "Hardware Configuration" can be used to program the properties and response of the S7-400 including the CPUs, e.g.
Multi-point interface MPI:
Definition of station addresses.
Startup/cycle behavior
Stipulation of the maximum cycle time and communications load
Address assignment:
Addressing of I/O modules.
Retentive ranges:
Definition of the number of retentive bit memories, counters, timers, data blocks and clock memories.
Size of the process image, local data.
Length of the diagnostics buffer
Protection level:
Definition of access authorization for program and data
System diagnostics:
Definition of the handling and scope of diagnostic messages
Timed interrupts:
Setting of periodicity
CPU 416-3 PN/DP additional:
PROFINET interface
Parameterization of time synchronization using NTP procedure
Indication and information functions
Status and error indicators:
LEDs indicate internal and external errors and operating states such as RUN, STOP, Restart, Test function, for example
Test functions:
The programming device can be used to display signal states in program execution, modify process tags irrespective of the user program, read out the contents of stack memories, run separate program steps and inhibit program components
Information functions:
The programming device can be used to provide the user with information on the memory capacity and operating mode of the CPU and the current utilization of the working and load memories
技術規(guī)范
商品編號
6ES7416-2XP07-0AB0
6ES7416-3XS07-0AB0
6ES7416-3ES07-0AB0