P-6501-4007 SFC050A-4517绂忓窞澶╄鍋�17骞村皥(zhu膩n)妤�(y猫)鎻愪緵寰峰湅(gu贸)鍘熻novotechnik鑸圭敤闆讳綅鍣紝鍘熻novotechnik鏃嬭綁(zhu菐n)鍌虫劅鍣ㄧ従(xi脿n)璨�
Novotechnik introduced potentiometers to general mechanical engineering in the 1950s.
Type P/N 锛歅-6501-4007 008218
Mechanical Data
Dimensions see drawing
Mounting with 3 clamps Z-1-31
Mechanical travel 360, continuous 掳
Permitted shaft loading (axial and radial)
static or dynamic force
45 N
Torque < 0.25 Ncm
Maximum operational speed 10 000 min-1
Weight 80 g
Electrical Data
Actual electrical travel 2 x 178 掳
Def. electrical range 2 x 100
(卤50掳 to electrical center within
electrical range)
Available eresistance values 2.5 k惟
Resistance tolerance 卤20 %
Repeatability 0.002 ( 0.007掳) %
Temperature coefficient
of the output-to-applied voltage ratio
typ. 5 ppm/K
Type P/N:P-2501-120-285-001 (angle 120掳, 2-section) 003266*
Type P/N:P-2501-240-286-001 (angle 240掳, 2-section) 003267*
Type P/N:P-2501-345-253-001 (angle 345掳, 2-section) 003268
Type P/N:P-2501-120-385-001 (angle 120掳, 3-section) 003263*
Type P/N:P-2501-240-386-001 (angle 240掳, 3-section) 003264*
Type P/N:P-2501-345-353-001 (angle 345掳, 3-section) 003265
Mechanical Data
Dimensions see dimension drawing
Mounting clamp with 2 cylinder screws M4x10
Mechanical travel 360 continous 掳
Permitted shaft loading (axial and radial)
static or dynamic force
15 N
Torque < 1.5 Ncm
Maximum operational speed 2,000 RPM
Weight 24 (2 sections) / 31 (3 sections) g
Electrical Data
Measuring range (dimension L) 120 卤2 240 卤2 345 卤2 掳
Defined electrical range 114 234 339 掳
Nominal resistance 1 2 5 k惟
Resistance tolerance 20 卤%
Independent linearity 0.3 卤%FS
Repeatability 0.01 掳
Interlinearity 1 卤%FS
Maximum permissible applied voltage 42 VDC
Recommended wiper operating current 鈮� 1 渭A
Maximum wiper current in case of mulfunction max. 10 mA
Effective temperature coefficient
of the output-to-applied voltage ratio
typ. 5 ppm/K
Insulation resistance (500 VDC) 鈮� 10 M惟
Dielectric strength (500 VAC, 50 Hz) 鈮� 100 渭A
Environmental Data
Temperature range -40 鈥� +100 掳C
Vibration (IEC 60068-2-6) 5鈥�.2000
Amax = 0.75
amax = 20
Hz
mm
g
Shock (IEC 60068-2-27) 50 (11 ms) g
Life 50x106 movements
Functional safety When using our products in safety-related systems, please contact us.
Protection class (DIN 40050 / IEC 529) IP40