国产精品久久久久久久久,四季AV一区二区夜夜嗨,日韩精品无码中文字幕电影,www.五月婷婷.com

資訊詳情
EMERSON ASK-167S-V
發(fā)布者:jiyang09  發(fā)布時間:2018-09-18 11:36:27
submersible, barrier, low smoke zero halogen and high fault current
rated cable glands.
CABLE CLEATS & HANGERS
Nylon, aluminium and stainless steel cable cleats to
retain LV-HV cables in single, trefoil, quad and bundled
arrangement with moderate and high levels of fault
current ratings. GRP and galvanised steel J type cable
support hangers.
Compression and mechanical shear bolt type cable lugs and connectors
for all cable conductors and voltages including 11kV, 33kV up to 66kV.
CABLE ACCESSORIES
Full range of cable labelling, bundling, management, insulation
(heat shrink), identification, crimping and connection products.
CABLE PULLING & LAYING
Cable pulling equipment for both trench and duct including cable rollers,
cable socks, cable drum jacks, winches, trailers and conduit rods. Cable
lubricants for power, telecom and fibre cable pulls.
CABLE DUCT SEALS & TRANSITS
Sealing cable ducts and building
penetrations against smoke, gas, water
ingress, humidity and dust while
assuring protection from rodents,
vibration, cable pull and also current
surge and electromagnetic
pulse/interference - WIMES, ATEX and
DSEAR compliant.
CABLE TROUGH
Trackside and elevated cable trough to protect power, signal and
telecoms cables – complete range of sizes and dimensions to
accommodate all cable routes.
INSTALL / SEAL / PROTECT
CABLE PROTECTION, DUCT & MARKERS
Cable protection Tapetile covers and Stokbords for LV, 11kV,
33kV and EHV applications – heavy duty plastic and concrete
cable protection. ENATS 12-24 (Class 1,2 & 3) underground
cable duct for LV-HV power, blown fibre and telecoms.
? Concrete
? GRP
? GRC
www.cablejoints.co.uk Thorne & Derrick
ELECTRICAL SAFETY
T&D are stockists and distributors for the CATU Electrical Safety Equipment range of products to
protect workers on underground cables, overhead power lines, switchgear and substations at LV,
MV, HV and EHV.
SAFETY
? Voltage Detectors
? Substation Safety & Intervention
? Switchgear Matting
? Earthing Clamps
? Insulating Gloves
? Portable Earthing & Short Circuit Systems
? Rescue Hooks
? Phase Comparators
ARC FLASH PROTECTION & CLOTHING
Arc Flash protective clothing including suits, coveralls, jackets, trousers, shirts, polo shirts
and helmets.
Underground Cables & Overhead Lines
www.cablejoints.co.uk Thorne & Derrick
Arc flash kits supplied in kit format for
protection up to 100 Cal:
? Carrying Bag
? Jacket & Dungarees
? Protective Hood With Face Shield
? Helmet
? Safety Glasses
CATU kits protect against arc flash that can
occur during reclosing of electrical switchgear
onto a fault, switchgear failure, circuit breaker
racking, excavating near live cables or
accidental contact with live conductors during
maintenance or cable jointing.
FEEDER PILLARS
LV POWER DISTRIBUTION
Cast iron, GRP, galvanised and stainless steel feeder pillars – above ground and
retractable pillars can be customised and equipped with electrical equipment to
suit project requirements.
DISTRIBUTION BOARDS & SERVICE PILLARS
Single and 3 phase distribution boards and pre-wired feeder pillars switched
and insulated for low voltage power distribution up to 3200amps. Single and 3
phase distribution boards and pre-wired feeder pillars switched and insulated
for low voltage power distribution up to 3200amps. Service pillars for LV
distribution networks providing fused connections where isolation of the
power supply can be controlled remotely from the user.
CUTOUTS
Complete range of house service, street lighting, heavy duty and overhead
service cut outs.
? Street Lighting Cut Outs (Primary & Secondary – Single/Double Pole Isolation)
? Pole Mounted CNE & SNE Cut Outs
? Overhead Pole Mounted Cut Outs 400A
? House Service Cut Outs – 3 Phase SNE & CNE 60/80A or 100A
? Heavy Duty Cut Outs 200A, 400A, 600A
www.cablejoints.co.uk Thorne & Derrick
FUSES & CUT OUTS
Current limiting and expulsion (non-current limiting)
fuses provide main or back-up protection against
overloads and overcurrents. Suitable for the protection
of distribution transformers, voltage transformers,
capacitor banks, motor circuits and cut outs.
MV POWER DISTRIBUTION
T&D distribute ABB MV Power Products - this includes indoor and
outdoor primary and secondary distribution equipment for substation
repair, retrofit and upgrade projects.
VACUUM CONTACTORS
Suitable for the control and protection of medium
voltage motors, transformers, power factor correction
banks and switching systems. Fitted with suitable
fuses suitable for MV circuits with fault levels up to
1000 MVA.
CIRCUIT BREAKERS
MV vacuum and SF6 gas circuit breakers for indoor
and outdoor applications. IEC/ANSI certified for
primary distribution, 11kV-33kV. Circuit breakers are
used in electrical distribution for control and
protection of cables, overhead lines, transformer
and distribution substations, motors, transformers,
generators and capacitor banks.
SURGE ARRESTERS
Surge arresters used for protection of MV electrical
equipment from over-voltages caused by lightning or
switching operations - made of metal oxide (MO) resistors
without spark gaps designed and tested according to IEC
60099-4. Suitable for MV, AC and DC traction systems.
www.cablejoints.co.uk Thorne & Derrick
EARTHING & LIGHTNING PROTECTION
Earthing, grounding, lightning protection and surge protection
equipment for electrical infrastructure, buildings and
substations: copper tape, earth bars, earth rods, Marconite,
Bentonite and full range of copper earthing accessories.
CABLES
Complete range of specialist and medium/high voltage cables for 11kV, 22kV
and 33kV networks – specialist cables including Panzerflex and Protolon.
? MV HV - BS6622 BS7835 BS7870
? Fire Resistant
? Offshore & Marine - NEK 606 BFOU RFOU
? Flexible Rubber Reeling Cables
? Low Smoke Zero Halogen
? Airfield Ground Lighting
HAZARDOUS AREAS
? Cable Accessories – Joints, Terminations, Glands & Cleats
? Flow, Temperature, Pressure & Level Measurement
? Heat, Flame & Fire Detection
? Heat Tracing Cables & Systems
? Plugs & Sockets
Experts In Equipment For Explosive Atmospheres
? Electrical Heating
? Control Stations & Pushbuttons
? Gas Detection
? Junction Boxes & Enclosures
? Signalling – Sounders & Beacons
www.cablejoints.co.uk Thorne & Derrick
? Underground Cables
? LV Joints – Mains Straight, Service, Branch & Pot End
? MV Joints – Straight, Branch, Pot-End 11kV 33kV 66kV
? MV Terminations – Indoor

GE 312A6091P001
GE 351A3488P041
GE 312A6091P003
GE 312A6091P004
GE 312A6091P002
GE 586A1430P015 (USESAFETY DATA SHEET
Section 1 - Chemical Product and Company Information
Product Name: S-1193 Silicone Epoxy Product Code: S-1193
Trade Name: Glyptal
Manufactured by:
GLYPTAL, INC.
305 Eastern Ave.
Chelsea, MA 02150
Telephone (617) 884-6918
IN CASE OF EMERGENCY:
CHEMTREC 1-800-424-9300
Product Use: Coatings
Not recommended for: Nonindustrial Use
Section 2 - Hazards Identification
NFPA Raings, risk phrases, and suggested WHMIS Hazard Categories:
GHS Ratings:
Flammable liquid 3 Flash point >= 23°C and <= 60°C (140°F)
Skin corrosive 2 Reversible adverse effects in dermal tissue, Draize score: >=
2.3 < 4.0 or persistent inflammation
Eye corrosive 1 Serious eye damage: Irreversible damage 21 days after
exposure, Draize score: Corneal opacity >= 3, Iritis > 1.5
Carcinogen 2 Limited evidence of human or animal carcinogenicity
Reproductive toxin 1B Presumed, Based on experimental animals
Organ toxin single
exposure
3 Transient target organ effects- Narcotic effects- Respiratory
tract irritation
Aspiration hazard 1 Aspiration Toxicity Category 1: Known (regarded)- human
evidence - hydrocarbons with kinematic viscosity < or = 20.5
mm2/s at 40° C.
Aquatic toxicity C3 Acute toxicity > 10.0 but < 100.0 mg/l and lack of rapid
degradability and log Kow > 4 unless BCF < 500 and unless
chronic toxicity > 1 mg/l
GHS Hazards
H227 Combustible liquid
H302 Harmful if swallowed
H315 Causes skin irritation
H318 Causes serious eye damage
H336 May cause drowsiness or dizziness
H351 Suspected of causing cancer
H360 May damage fertility or the unborn child
H401 Toxic to aquatic life
GHS Precautions
P202 Do not handle until all safety precautions have been read and understood
P210 Keep away from heat/sparks/open flames/hot surfaces – No smoking
P233 Keep container tightly closed
P240 Ground/bond container and receiving equipment
P241 Use explosion-proof electrical/ventilating/light/…/equipment
P242 Use only non-sparking tools
P243 Take precautionary measures against static discharge
SDS for: S-1193 Page 1 of 16
Printed: 6/3/2015 at 10:54:51PM
P261 Avoid breathing dust/fume/gas/mist/vapours/spray
P264 Wash skin thoroughly after handling
P271 Use only outdoors or in a well-ventilated area
P273 Avoid release to the environment
P280 Wear protective gloves/protective clothing/eye protection/face protection
P331 Do NOT induce vomiting
P362 Take off contaminated clothing and wash before reuse
P301+P312 IF SWALLOWED: Call a POISON CENTER or doctor/physician if you feel unwell
P303+P361+P353 IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing.
Rinse skin with water/shower
P304+P312 IF INHALED: Call a POISON CENTER or doctor/physician if you feel unwell
P304+P340 IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable
for breathing
P305+P351+P338 IF IN EYES: Rinse continuously with water for several minutes. Remove contact
lenses if present and easy to do – continue rinsing
P308+P313 IF exposed or concerned: Get medical advice/attention
P332+P313 If skin irritation occurs: Get medical advice/attention
P337+P313 If eye irritation persists, get medical advice/attention
P370+P378 In case of fire: Use dry sand, dry chemical or alcohol-resistant foam for extinction
P403+P233 Store in a well ventilated place. Keep container tightly closed
P403+P235 Store in a well ventilated place. Keep cool
P501 Dispose of contents/container to an approved waste disposal plant
Signal Word: Danger
Section 3 - Composition/Information on Ingredients
Chemical Name CAS number Weight Concentration %
Methyl Isobutyl Ketone 108-10-1 10.00% - 20.00%
n-Butyl Acetate 123-86-4 5.00% - 10.00%
Propylene Glycol Methyl Ether Acetate 108-65-6 5.00% - 10.00%
n-Butanol 71-36-3 1.00% - 5.00%
Cyclohexanone 108-94-1 1.00% - 5.00%
Xylene (mixed isomers) 1330-20-7 1.00% - 5.00%
Section 4 - First Aid Measures
INHALATION - Remove from area to fresh air. If symptomatic, contact a poison control center, emergency room, or
physician as further medical treatment may be necessary. Administer oxygen if a qualified operator is available.
EYE CONTACT - In case of eye contact, flush the eyes with water for fifteen (15) minutes. If contact lenses are
worn, quickly remove them, then flush the eyes with water. If irritation persists, contact a poison control center,
emergency room, or physician as further medical treatment may be necessary.
SKIN CONTACT - In case of skin contact, remove contaminated clothing. Flush the skin with large amounts of
water, then wash the skin with soap and water. If symptoms persist, contact a poison control center, emergency
SDS for: S-1193 Page 2 of 16
Printed: 6/3/2015 at 10:54:53PM
room, or physician as further medical treatment may be necessary.
INGESTION - If material is ingested, seek immediate medical attention. Do not induce vomiting. If vomiting occurs
spontaneously, keep the head below the hips to prevent aspiration of liquid into the lungs . Contact a poison control
center, emergency room, or physician as further medical treatment will be necessary .
Section 5 - Fire Fighting Measures
Flash Point: 35 C (95 F)
LEL: 1.00 UEL: 12.00
EXTINGUISHING MEDIA: Use carbon dioxide (CO2), "alcohol" foam, dry chemical
UNUSUAL FIRE OR EXPLOSION HAZARDS: The product vapor is heavier than air and may travel a considerable
distance to a source of ignition and flashback. Closed containers may explode or burst when exposed to extreme
heat. May produce hazardous decomposition products when exposed to extreme heat.
HAZARDOUS COMBUSTION PRODUCTS: See section 10 for a list of hazardous decomposition products for this
mixture.
FIRE FIGHTING: Water spray may be ineefective. If water is used, fog nozzles are prefereable. Water may be used
to cool closed containers to prevent pressure build-up and possible autoignition or explosion when exposed to
extreme heat. If evacuation of personnel is necessary, evacuate to an upwind area . Decontaminate personnel and
equipment with a water wash-down after fire and smoke exposure.
FIRE FIGHTING EQUIPMENT: Firemen and emergency responders: wear full turnout gear or Level A equipment,
including positive-pressure, self-contained breathing apparatus (SCBA).
Section 6 - Accidental Release Measures
SPILL AND LEAK PROCEDURES: Spill supervisor - Ensure cleanup personnel wear all appropriate Personal
Protective Equipment (PPE), including respiratory protection. Remove all ignition sources. Keep nonessential
personnel away from the contaminated area.
SMALL SPILLS: Ventilate the contaminated area. Using nonsparking tools, mix the appropriate sorbent into the
spilled material. Use an absorbent like sawdust for aqueous, waterborne, and solvent-borne coatings.
Collect the saturated sorbent and transfer it into a covered container. Steel containers are acceptable for all wastes
except wastes which contain acid. Use suitable plastic containers for acid-bearing wastes.
Dispose of the waste in compliance with all Federal, state, regional, and local regulations.
LARGE SPILLS: Prevent this material from entering sewers and watercourses by diking or impounding the spilled
material. Advise authorities if the product has entered or may enter, sewers, watercourses, or extensive land areas .
Ventilate the contaminated area. Using nonsparking tools, mix the appropriate sorbent into the spilled material. Use
an absorbent like sawdust for aqueous, waterborne, and solvent-borne coatings.
SDS for: S-1193 Page 3 of 16
Printed: 6/3/2015 at 10:54:53PM
Collect the saturated sorbent and transfer it into a covered container. Steel containers are acceptable for all wastes
except wastes which contain acid. Use suitable plastic containers for acid-bearing wastes.
Label the waste container. Dispose of the waste in compliance with all Federal, state, regional, and local regulations.
Section 7 - Handling and Storage
HANDLING PRECAUTIONS: Wear all appropriate Personal Protective Equipment (PPE). Wear respiratory protection
or ensure adequate ventilation at all times as vapors can accumulate in confined or poorly ventilated areas. Use the
product in a manner which minimizes splashes and/or the creation of dust. Keep containers closed when not in use.
Do not handle or store material near heat, sparks, open flames, or other sources of ignition. Store at room
temperatures, i.e., 50 to 85 F (10 to 30 C).
STORAGE: Prevent from freezing. Do not store above 95 F (35 C).
Store only in original containers.
Section 8 - Exposure Controls / Personal Protection
Chemical Name / CAS No. OSHA Exposure Limits ACGIH Exposure Limits Other Exposure Limits
Methyl Isobutyl Ketone
108-10-1
TLV 20 ppm - TWA
TLV 75 ppm - STEL
TWA 100 ppm (Z-1)
TWA 50 ppm (P0)
STEL 75 ppm (P0)
Not Established
n-Butyl Acetate
123-86-4
TLV 150 ppm - TWA
TLV 200 ppm - STEL
PEL 150 ppm - TWA
VPEL 150 ppm - TWA
VPEL 200 ppm - STEL
Not Established
Propylene Glycol Methyl
Ether Acetate
108-65-6
PEL N/A TLV N/A Not Established
n-Butanol
71-36-3
PEL 100 ppm - TWA TLV 20 ppm - TWA
VPEL 50 ppm - Ceiling (skin)
Not Established
Cyclohexanone
108-94-1
TLV 20 ppm - TWA (skin)
TLV 50 ppm - STEL (skin)
PEL 50 ppm - TWA
VPEL 25 ppm - TWA (skin)
Not Established
Xylene (mixed isomers)
1330-20-7
TLV 100 ppm - TWA
TLV 150 ppm - STEL
PEL 100 ppm - TWA
PEL 150 ppm - STEL
Not Established
ENGINEERING: Provide general dilution of local exhaust ventilation in volume and pattern to keep concentration of
ingredients listed in Section 2 below the lowest suggested exposure limits, the LEL below the stated limit, and to
remove decomposition products during welding or flame cutting.
This coating may contain materials classified as nuisance particulates (listed "as Dust" in Section 2) which may be
present at hazardous levels only during sanding or abrading of the dried film. If no specific dusts are listed in Section
2, the applicable limits for nuisance dusts are ACGIH TLV 10 mg/m3 (total dust), 3 mg/m3 (respirable fraction), OSHA
PEL 15 mg/m3 (total dust), 5 mg/m3 (respirable fraction).
Ensure processing (curing) ovens are properly vented to prevent the introduction of processing fumes into the
workplace. Use explosion-proof equipment and good manufacturing practice.
VENTILATION: Use only with adequate ventilation, i.e., ventilation in compliance with occupational exposure limits.
Refer to OSHA standards 1910.94, 1910.107, 1910.108.
SDS for: S-1193 Page 4 of 16
Printed: 6/3/2015 at 10:54:53PM
PERSONAL PROTECTIVE EQUIPMENT
EYES:
Wear splash goggles. If extra protection is required, wear a face shield over the splash goggles. Face shields are
effective only if worn in addition to splash goggles.
PROTECTIVE GLOVES:
Wear chemical-resistant gloves (butyl rubber or neoprene) . Protective gloves should be inspected frequently and
discarded when they exhibit cuts, tears, pinholes, or signs of excessive wear. If necessary, wear a chemical-resistant,
butyl-rubber apron and other protective clothing, as deemed appropriate, to avoid skin contact with material.
RESPIRATORY PROTECTION:
Respiratory protection may not be needed if the local exhaust is sufficient to maintain levels of hazardous ingredients
below occupational exposure limits. Where ventilation is inadequate, use a NIOSH/MSHA-approved, air-purifying
respirator equipped with the appropriate chemical cartridges or positive-pressure, air-supplied respirator. Read the
respirator manufacturer's instructions and literature carefully to determine the type of airborne contaminants against
which the respirator is effective, its limitations, and how it is to be properly fitted and used .
CONTAMINATED EQUIPMENT: Dispose of the waste in compliance with all Federal, state, regional, and local
regulations.
Section 9 - Physical and Chemical Properties
This mixture typically exhibits the following properties under normal circumstances:
Appearance Gray Liquid Odor Solvent odor
Physical State Liquid Vapor Density Heavier than air
Vapor Pressure 4.6 mm Hg @ 68 F Evaporation Rate Slower than ether
Boiling Range 116 to 156 °C Specific Gravity (SG) 1.229
Lbs VOC/Gallon Solids 10.4 Lbs VOC/Gallon Less Water 4.38
and Exempt Solvent
Section 10 - Stability and Reactivity
Stability:
STABLE
Components of this mixture are incompatible with the following materials:
Alkali metals, Aluminum, Halogens, Lead, Strong mineral acids, Strong oxidizing agents
Amines, copper, copper alloys, strong alkalis, strong mineral acids, strong oxidizing agents, strong reducing
agents
Strong oxidizing agents
Strong oxidizing agents, strong acids, strong bases
This mixture is likely to exhibit the following combustion products:
Carbon Dioxide, Carbon Monoxide
Hazardous polymerization will not occur.
Section 11 - Toxicological Information
Component Toxicity
108-10-1 Methyl Isobutyl Ketone
SDS for: S-1193 Page 5 of 16
Printed: 6/3/2015 at 10:54:53PM
Oral LD50: 2,080 mg/kg (Rat) Inhalation LC50: 8 mg/L (Rat)
123-86-4 n-Butyl Acetate
Inhalation LC50: 21 mg/L (Rat)
108-65-6 Propylene Glycol Methyl Ether Acetate
Dermal LD50: 5,000 mg/kg (Rabbit)
71-36-3 n-Butanol
Oral LD50: 790 mg/kg (Rat) Dermal LD50: 3,400 mg/kg (Rabbit)
108-94-1 Cyclohexanone
Oral LD50: 1,534 mg/kg (Rat) Dermal LD50: 3,160 mg/kg (Rabbit) Inhalation LC50: 6 mg/L (Rat)
1330-20-7 Xylene (mixed isomers)
Oral LD50: 4,300 mg/kg (Rat) Dermal LD50: 2,000 mg/kg (Rabbit)
Toxicological information: The preparation has been assessed following the conventional method of the Dangerous
Preparations Directive 1999/45/EC and classified for toxicological hazards accordingly. See Sections 3 and 15 for
details.
Routes of Entry:
Inhalation Skin Contact Eye Contact Ingestion
Exposure to this material may affect the following organs:
Blood Kidneys Liver Lungs Central Nervous System Reproductive System
Effects of Overexposure
108-10-1 Methyl Isobutyl Ketone
Signs and symptoms of exposure to this material through breathing, swallowing,
and/or passage of the material through the skin may include: mouth and throat
irritation (soreness, dry or scratchy feeling. Cough), stomach or intestinal upset
(nausea, vomiting, diarrhea), irritation (nose, throat, airways), central nervous system
depression (dizziness, drowsiness, weakness, fatigue, nausea, headache,
unconsciousness).
Eye Contact May cause mild irritation. Symptoms include stinging, tearing, and redness.
Ingestion Swallowing small amounts of this material during normal handling is not likely to cause
harmful effects. Swallowing large amounts may be harmful. This material can get into
the lungs during swallowing or vomiting. This results in lung inflammation and other
lung injury.
Inhalation Breathing of vapor or mist is possible. Breathing small amounts of this material during
normal handling is not likely to cause harmful effects. Breathing large amounts may be
harmful. Symptoms are not expected at air concentrations below the recommended
exposure limits.
Skin Contact May cause mild skin irritation. Prolonged or repeated contact may dry the skin.
Symptoms include redness, burning, drying and cracking of skin, and skin burns.
Passage of this material into the body through the skin is possible, but it is unlikely
that this would result in harmful effects during safe handling and use .
108-65-6 PM Acetate
Moderate health hazard. Moderate eye irritant. Mucous membrane irritant. Slight
inhalation hazard. Slight ingestion hazard. Slight skin absorption hazard.
Eye Contact May cause moderate irritation, including burning sensation, tearing, redness or
swelling.
Ingestion Ingestion may cause gastrointestinal discomfort with any or all of the following
symptoms: nausea, vomiting, lethargy, or diarrhea.
SDS for: S-1193 Page 6 of 16
Printed: 6/3/2015 at 10:54:53PM
Inhalation Prolonged overexposure to either vapor or mist may cause coughing, shortness of
breath, dizziness and drunkenness.
Skin Contact No significant signs or symptoms indicative of any health hazard are expected to
occur as a result of skin contact. Possible systemic toxicity by skin absorption.
108-88-3 Toluene
Signs of symptoms of exposure to this material through breathing, swallowing, and/or
版權(quán)聲明:工控網(wǎng)轉(zhuǎn)載作品均注明出處,本網(wǎng)未注明出處和轉(zhuǎn)載的,是出于傳遞更多信息之目的,并不意味 著贊同其觀點或證實其內(nèi)容的真實性。如轉(zhuǎn)載作品侵犯作者署名權(quán),或有其他諸如版權(quán)、肖像權(quán)、知識產(chǎn)權(quán)等方面的傷害,并非本網(wǎng)故意為之,在接到相關(guān)權(quán)利人通知后將立即加以更正。聯(lián)系電話:0571-87774297。
今日最新資訊
熱門資訊
0571-87774297