西門子SIPLUS CPU312C 銷售訂貨號(hào):
![]() |
6AG1312-5BF04-2AY0
SIPLUS S7-300 CPU312C WITH CONFORMAL COATING ACCORDING EN50155 T1 CAT 1 CL A BASED ON 6ES7312-5BF04-0AB0 . COMPACT CPU WITH MPI, 10 DI/6 DO, 2 FAST COUNTERS (10 KHZ), INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING MEMORY, FRONT CONNECTOR (1 X 40PIN) AND MICRO MEMORY CARD REQUIRED
|
![]() |
6AG1312-5BF04-7AB0
SIPLUS S7-300 CPU312C FOR MEDIAL STRESS -25 ... +70 GRAD C BASED ON 6ES7312-5BF04-0AB0 . COMPACT CPU WITH MPI, 10 DI/6 DO, 2 FAST COUNTERS (10 KHZ), INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING MEMORY, FRONT CONNECTOR (1 X 40PIN) AND MICRO MEMORY CARD REQUIRED
|
西門子S7-300PLC 優(yōu)勢(shì)價(jià)格 現(xiàn)貨銷售
聯(lián)系人 :卜社幫( 銷售經(jīng)理 )24小時(shí)服務(wù)熱線 :18202105796
電話( Tel ): 021-60641323 傳真(Fax):021-57872917
工作QQ: 2880583563
地址( Add ):上海市松江區(qū)弘翔路58弄195號(hào)
西門子SIPLUS CPU312C 產(chǎn)品簡介:
帶有集成式數(shù)字量輸入/輸出的緊湊型 CPU
適用于對(duì)處理性能有較高要求的小型應(yīng)用
具有工藝功能
CPU 運(yùn)行需要微存儲(chǔ)卡(MMC)。
注:
SIPLUS extreme 產(chǎn)品基于 SIMATIC 標(biāo)準(zhǔn)產(chǎn)品。此處的內(nèi)容摘自相關(guān)的標(biāo)準(zhǔn)產(chǎn)品。增加了與 SIPLUS extreme 相關(guān)的信息
CPU 312C 是一種緊湊型 CPU,用于對(duì)處理速度要求很高的小型應(yīng)用。集成數(shù)字量輸入/輸出,支持直接連接過程。
集成技術(shù)工程的其他用途包括:
計(jì)數(shù)
頻率測(cè)量
周期測(cè)量
脈寬調(diào)制
CPU 312C 安裝有:
微處理器;
處理器處理每條二進(jìn)制指令的時(shí)間可達(dá) 100 ns。
擴(kuò)展存儲(chǔ)器;
64 KB 高速工作存儲(chǔ)器(相當(dāng)于大約 21 K 的指令),用于執(zhí)行相關(guān)的程序,為用戶程序提供充分的空間;
SIMATIC 微型存儲(chǔ)卡(最大 8 MB)作為程序的裝載存儲(chǔ)器,還允許將項(xiàng)目(包括符號(hào)和注釋)存儲(chǔ)在 CPU 中。
靈活的擴(kuò)展能力
多達(dá) 8 個(gè)模塊,(1排結(jié)構(gòu))
MPI多點(diǎn)接口
內(nèi)置 MPI 接口可以最多同時(shí)建立 6 個(gè)與 S7-300/400 或與 PG、PC、OP 的連接。在這些連接中,始終分別為 PG 和 OP 各保留一個(gè)連接。通過“全局?jǐn)?shù)據(jù)通訊”,MPI可以用來建立最多16個(gè)CPU組成的簡單網(wǎng)絡(luò)。
內(nèi)置輸入/輸出;
10個(gè)數(shù)字量輸入(均可用于報(bào)警處理)和6個(gè)數(shù)字量輸出,用于將過程信號(hào)連接到 CPU 312C。
口令保護(hù);
用戶程序使用密碼保護(hù),可防止非法訪問。
塊加密;
函數(shù) (FC) 和功能塊 (FB) 可以通過 S7-Block Privacy,加密存儲(chǔ)于 CPU 以保護(hù)專有技術(shù)。
診斷緩沖;
診斷緩沖區(qū)中可存儲(chǔ)最后 500 條錯(cuò)誤和中斷事件,其中的 100 條事件可以長期存儲(chǔ)。
免維護(hù)的數(shù)據(jù)后備;
如果發(fā)生斷電,則可通過 CPU 將所有保持性數(shù)據(jù)自動(dòng)寫入到 SIMATIC 微型存儲(chǔ)卡(MMC 卡)上,且將在再次通電時(shí)保持不變。
可參數(shù)化的特性
可以使用 STEP 7 對(duì) S7 的組態(tài)、屬性以及CPU的響應(yīng)進(jìn)行參數(shù)設(shè)置:
概述;
定義名稱、上位名稱和位置 ID
啟動(dòng);
定義 CPU 的啟動(dòng)特性和監(jiān)視時(shí)間
循環(huán)/時(shí)鐘存儲(chǔ)器;
指定最大循環(huán)時(shí)間和負(fù)載,設(shè)定時(shí)鐘存儲(chǔ)器地址。
記憶性;
設(shè)置保持區(qū)
日時(shí)鐘中斷;
設(shè)定起始日期、起始時(shí)間和間隔周期
周期中斷;
周期設(shè)定
系統(tǒng)診斷;
確定診斷消息的處理和范圍
時(shí)鐘;
設(shè)定AS內(nèi)或MPI上的同步類型
防護(hù)等級(jí);
定義程序和數(shù)據(jù)的訪問權(quán)限
通訊;
保留連接源
MPI多點(diǎn)接口;
定義站地址
數(shù)字量輸入/輸出
地址設(shè)定,輸入繼電器和過程中斷
集成功能“計(jì)數(shù)器”
設(shè)定地址,以及 “連續(xù)計(jì)數(shù)”“單次計(jì)數(shù)”“周期計(jì)數(shù)”“頻率測(cè)量”和“脈寬調(diào)制”模式下的參數(shù)分配
顯示功能與信息功能
狀態(tài)和故障指示;
發(fā)光二極管顯示,例如,硬件、編程、定時(shí)器或I/O出錯(cuò)以及運(yùn)行模式,如RUN、STOP、Startup。
測(cè)試功能;
使用編程器,可顯示用戶執(zhí)行過程中的信號(hào)狀態(tài),獨(dú)立于用戶程序修改過程變量,并輸出堆棧存儲(chǔ)器的內(nèi)容。
信息功能;
通過編程器以文本形式為用戶提供存儲(chǔ)能力信息、CPU的運(yùn)行模式,以及主存儲(chǔ)器和裝載存儲(chǔ)器當(dāng)前的使用情況、當(dāng)前的循環(huán)時(shí)間和診斷緩沖區(qū)的內(nèi)容。
集成的通訊功能
編程器/OP 通訊
全局?jǐn)?shù)據(jù)通訊
S7 基本通訊
S7 通訊(只是服務(wù)器)
集成功能
計(jì)數(shù)器;
2個(gè)通道(最高 10 kHz),具有獨(dú)立方向的比較器,可直接連接到 24V 增量型編碼器。
2通道頻率測(cè)量;
允許進(jìn)行頻率測(cè)量(高達(dá) 10 kHz),例如,測(cè)量軸速或吞吐量(每個(gè)測(cè)量周期內(nèi)的件數(shù))。
周期測(cè)量
2個(gè)通道??蓽y(cè)量計(jì)數(shù)信號(hào)的周期時(shí)間,計(jì)數(shù)頻率最高為 1 KHz。
脈寬調(diào)制;
2個(gè)輸出可直接連接控制閥、執(zhí)行器、開關(guān)設(shè)備、加熱裝置等,例如采樣頻率為 2.5 kHz。 可設(shè)置周期長度并可在運(yùn)行時(shí)修改占空比。
報(bào)警輸入(所有數(shù)字量輸入);
報(bào)警輸入可以檢測(cè)過程事件,并在最短的時(shí)間內(nèi)觸發(fā)響應(yīng)。
西門子SIPLUS CPU312C 技術(shù)參數(shù):
Order number |
6AG1312-5BF04-2AY0 |
6AG1312-5BF04-7AB0 |
|
---|---|---|---|
SIPLUS S7-300 CPU312C EN50155 |
SIPLUS S7-300 CPU312C |
||
General information |
|
|
|
Engineering with |
|
|
|
|
STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203 |
STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203 |
|
Supply voltage |
|
|
|
Rated value (DC) |
|||
|
Yes |
Yes |
|
Power loss |
|
|
|
Power loss, typ. |
8 W |
8 W |
|
Memory |
|
|
|
Work memory |
|
|
|
|
64 kbyte |
64 kbyte |
|
|
64 kbyte |
64 kbyte |
|
Load memory |
|
|
|
|
8 Mbyte |
8 Mbyte |
|
CPU processing times |
|
|
|
for bit operations, typ. |
0.1 μs |
0.1 μs |
|
for word operations, typ. |
0.24 μs |
0.24 μs |
|
for fixed point arithmetic, typ. |
0.32 μs |
0.32 μs |
|
for floating point arithmetic, typ. |
1.1 μs |
1.1 μs |
|
Counters, timers and their retentivity |
|
|
|
S7 counter |
|
|
|
|
256 |
256 |
|
IEC counter |
|
|
|
|
Yes |
Yes |
|
S7 times |
|
|
|
|
256 |
256 |
|
IEC timer |
|
|
|
|
Yes |
Yes |
|
Data areas and their retentivity |
|
|
|
Flag |
|
|
|
|
256 byte |
256 byte |
|
Address area |
|
|
|
I/O address area |
|
|
|
|
1 024 byte |
1 024 byte |
|
|
1 024 byte |
1 024 byte |
|
Process image |
|
|
|
|
1 024 byte |
1 024 byte |
|
|
1 024 byte |
1 024 byte |
|
Operating hours counter |
|
|
|
|
1 |
1 |
|
Digital inputs |
|
|
|
integrated channels (DI) |
10 |
10 |
|
Digital outputs |
|
|
|
integrated channels (DO) |
6 |
6 |
|
Analog inputs |
|
|
|
integrated channels (AI) |
0 |
0 |
|
Analog outputs |
|
|
|
integrated channels (AO) |
0 |
0 |
|
1. Interface |
|
|
|
Interface type |
Integrated RS 485 interface |
Integrated RS 485 interface |
|
Physics |
RS 485 |
RS 485 |
|
Functionality |
|
|
|
|
Yes |
Yes |
|
|
No |
No |
|
|
No |
No |
|
|
No |
No |
|
Communication functions |
|
|
|
PG/OP communication |
Yes |
Yes |
|
Data record routing |
No |
No |
|
Global data communication |
|
|
|
|
Yes |
Yes |
|
S7 basic communication |
|
|
|
|
Yes |
Yes |
|
S7 communication |
|
|
|
|
Yes |
Yes |
|
S5 compatible communication |
|
|
|
|
Yes; via CP and loadable FC |
Yes; via CP and loadable FC |
|
Number of connections |
|
|
|
|
6 |
6 |
|
Integrated Functions |
|
|
|
Number of counters |
2; See "Technological Functions" manual |
2; See "Technological Functions" manual |
|
Counting frequency (counter) max. |
10 kHz |
10 kHz |
|
Frequency measurement |
Yes |
Yes |
|
Number of frequency meters |
2; up to 10 kHz (see "Technological Functions" manual) |
2; up to 10 kHz (see "Technological Functions" manual) |
|
controlled positioning |
No |
No |
|
integrated function blocks (closed-loop control) |
No |
No |
|
PID controller |
No |
No |
|
Number of pulse outputs |
2; Pulse width modulation up to 2.5 kHz (see "Technological Functions" Manual) |
2; Pulse width modulation up to 2.5 kHz (see "Technological Functions" Manual) |
|
Limit frequency (pulse) |
2.5 kHz |
2.5 kHz |
|
Ambient conditions |
|
|
|
Ambient temperature during operation |
|
|
|
|
-25 °C; = Tmin |
-25 °C; = Tmin |
|
|
60 °C; = Tmax; the rated temperature range of -25 ... +55 °C (T1) applies for the use on railway vehicles according to EN50155 |
70 °C; = Tmax; 60 °C @ UL/cUL, ATEX and FM use |
|
Ambient temperature during storage/transportation |
|
|
|
|
-40 °C |
-40 °C |
|
|
70 °C |
70 °C |
|
Extended ambient conditions |
|
|
|
|
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
Tmin ... Tmax at 1080 hPa ... 795 hPa (-1000 m ... +2000 m) // Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa (+2000 m ... +3500 m) // Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa (+3500 m ... +5000 m) |
|
Relative humidity |
|
|
|
|
100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation |
100 %; RH incl. condensation/frost (no commissioning under condensation conditions) |
|
Resistance |
|
|
|
|
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation in corrosive atmospheres! |
Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! |
|
|
Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
Yes; Class 3C4 (RH < 75%) incl. salt spray according to EN 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! |
|
|
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
Yes; Class 3S4 incl. sand, dust. The supplied connector covers must remain on the unused interfaces during operation! |
|
Configuration |
|
|
|
Programming |
|
|
|
Programming language |
|
|
|
|
Yes |
Yes |
|
|
Yes |
Yes |
|
|
Yes |
Yes |
|
|
Yes |
Yes |
|
|
Yes |
Yes |
|
|
Yes |
Yes |
|
Know-how protection |
|
|
|
|
Yes |
Yes |
|
|
Yes; With S7 block Privacy |
Yes; With S7 block Privacy |
|
Dimensions |
|
|
|
Width |
80 mm |
80 mm |
|
Height |
125 mm |
125 mm |
|
Depth |
130 mm |
130 mm |
|
Weights |
|
|
|
Weight, approx. |
410 g |
410 g |