国产精品久久久久久久久,四季AV一区二区夜夜嗨,日韩精品无码中文字幕电影,www.五月婷婷.com

璩囪▕瑭虫儏
闆诲姏闆荤簻鍨嬭櫉澶у叏锛堟湁閭d簺)
鐧�(f膩)甯冭€咃細tjxmdl1  鐧�(f膩)甯冩檪闁擄細2012-06-03 17:40:08
6kV~35kV 涓綆澹撻妳鑺強閶佽姱浜よ伅(li谩n)鑱氫箼鐑禃绶i浕鍔涢浕绾滐紙YJV闆荤簻锛孻JV22闆荤簻锛孻JLV闆荤簻锛孻JLV22闆荤簻锛�
XLPE Insulated Power Cable
銆€銆€浜よ伅(li谩n)鑱氫箼鐑禃绶i浕鍔涢浕绾滄槸閲囩敤鍖栧(xu茅)鏂规硶鎴栫墿鐞嗘柟娉�,浣胯仛涔欑儻鍒嗗瓙鐢辩窔鍨嬪垎瀛愮祼(ji茅)妲�(g貌u)杞�(zhu菐n)璁�?y艒u)妲款惂S缍�(w菐ng)鐙€绲�(ji茅)妲�(g貌u),鐢辩啽濉戞€х殑鑱氫箼鐑畩鎴愮啽鍥烘€х殑浜よ伅(li谩n)鑱氫箼鐑�,寰炶€屾彁楂樹簡鑱氫箼鐑殑鑰愯€佸寲鎬ц兘銆佹姊版€ц兘鍜岃€愮挵(hu谩n)澧冭兘鍔�锛屽苟淇濇寔浜嗗劒(y艒u)鑹殑闆绘埃鎬ц兘銆�
銆€銆€浜よ伅(li谩n)鑱氫箼鐑禃绶i浕鍔涢浕绾滃皫(d菐o)楂旂殑鍏佽ū闀锋湡鏈€楂樻韩鐐�90鏀濇皬搴�锛岃純浣庣禃绶i浕绾�銆佽仛姘箼鐑禃绶i浕绾滃拰鑱氫箼鐑禃绶i浕绾滈珮锛屼笖鍏锋湁閲嶉噺杓�銆佺祼(ji茅)妲�(g貌u)绨″柈銆佷娇鐢ㄦ柟渚�銆佽€愬寲瀛�(xu茅)鑵愯潟鍜屾暦瑷�(sh猫)涓嶅彈钀藉樊闄愬埗绛夊劒(y艒u)榛�銆�
26/35KV闆诲姏闆荤簻锛�18/30KV浜よ伅(li谩n)闆荤簻锛�12/20KVYJV闆荤簻锛�8.7/15KVYJV22闆荤簻绶氾紝6/10KV閶佽姱浜よ伅(li谩n)闆荤簻绶�锛�3.6/6KVYJLV鍠姱闆荤簻銆€銆€
涓綆澹撲氦鑱�(li谩n)闆荤簻鐢�(ch菐n)鍝佹婧�  Standard
銆€銆€鏈敘(ch菐n)鍝佹寜GB12706銆婇瀹氶浕澹�35V鍙婁互涓嬮妳鑺�銆侀媮鑺鏂欑禃绶i浕鍔涢浕绾溿€嬫婧栫敓鐢�(ch菐n)锛屽悓鏅傞倓鍙牴鎿�(j霉)鐢ㄦ埗闇€瑕佹寜鍦嬮殯闆诲伐濮斿摗鏈冩帹钖︽婧朓EC銆佽嫳鍦嬫婧�銆佸痉鍦嬫婧栧強缇庡湅妯欐簴鐢熺敘(ch菐n)銆�
The product is manufactured according to the standard of銆奊B12706 or IEC銆丅S銆丏IN and ICEA upon request.
閬╃敤鑼冨湇  Applications
銆€銆€鏈敘(ch菐n)鍝侀仼鐢ㄤ簬宸ラ牷椤嶅畾闆诲3.6/6kv锝�26/35kv杓搁厤闆荤窔璺綔閰嶉€侀浕鑳藉瓙鐢�銆�
The product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv锝�26/35kv.
浣跨敤鐗规€�  Operating characteristics
路 宸ラ牷椤嶅畾闆诲U0/U鐐�3.6/6kv锝�26/35kv銆�
Rated power-frepuency voltage U0/U: 3.6/6kv锝�26/35kv.
路 闆荤簻灏�(d菐o)楂旂殑鏈€楂樺厑瑷卞伐浣滄韩搴︼細90鈩�銆�
Max.admissible operating temperature of the conductor:90鈩�.
路 鐭矾鏅傦紙鏈€闀锋檪闁撲笉瓒呴亷5s锛夐浕绾滃皫(d菐o)楂旂殑鏈€楂樻韩搴︿笉瓒呴亷2500C銆�
Max. short-circurt temperature of conductor shall not exceed 2500C.
(5s maximum duration)
路 闆荤簻鏁疯ō(sh猫)鏅傜挵(hu谩n)澧冩韩搴︽噳(y墨ng)涓嶄綆浜�00C銆�
The ambient temperature under installation should not below 00C.
路 闆荤簻褰庢洸鍗婂緫锛氫笁鑺浕绾滀笉灏忎簬闆荤簻澶栧緫15鍊�锛涘柈鑺浕绾滀笉灏忎簬闆荤簻澶栧緫20鍊�銆�
The bending radius of a single-core cable should not less than 20 times of the cable diameter.
The bending radius of a single-core cable should not less than 15 times of the cable diameter.
闆荤簻椤嶅畾闆诲鐨勯伕鎿�   Voltage designation
路 闆荤簻鐨勯瀹氶浕澹撴噳(y墨ng)閬╁悎浜庨浕绾滅郴绲�(t菕ng)鐨勯亱琛岀媭娉侊紝鐢║0/U锛圲m锛塳v琛ㄧず銆�
U0锛嶉浕绾滆ō(sh猫)瑷堢敤鐨勫皫(d菐o)楂斿皪鍦版垨閲戝爆灞忚斀涔嬮枔鐨勯瀹氬伐闋婚浕澹擄紱
U锛嶉浕绾滆ō(sh猫)瑷堢敤鐨勫皫(d菐o)楂旈枔鐨勯瀹氬伐闋婚浕澹�锛�
Um锛嶈ō(sh猫)鍌欏彲鎵垮彈鐨勨€滄渶楂樼郴绲�(t菕ng)闆诲鈥濈殑鏈€澶у€笺€�
The rated voltage of the cable for a given applixation shall be suitable for the operating conditions
in the system in which the cable is used,and is expressed in the form of U0/U锛圲m锛塳v
Where:
U0锛峊he rated power-frequency voltage between conductors and earth metallic screen ,for which the cable designed;
U 锛� The rated power-frequency voltage between conductos, for which the cable designed;
Um锛� The maximum value of the鈥渉ighest system voltage鈥漟or which the equipment may beused.
路 涓夌浉绯荤当(t菕ng)鐢ㄩ浕绾滅殑U0鍊兼帹钖﹀涓嬭〃锛�
The values of U0 recommened for cable to be used in three-phase systems are listed below:

銆€

U kv U m kv U 0 * kv
A 鍜� B 椤炵郴绲�(t菕ng) System categories A and B C 椤炵郴绲�(t菕ng) Systems categories C
6 7.2 3.6 6
10 12 6 8.7
15 17.5 8.7 12
20 24 12 18
30 36 18 锛�
35 40.5 21 26
A椤炵郴绲�(t菕ng)鈹€鈹€瑭查绯荤当(t菕ng)浠讳綍涓€鐩稿皫(d菐o)楂旇垏鍦板拰鎺ュ湴灏�(d菐o)楂旀帴瑙告檪锛岃兘鍦�1min鍏�(n猫i)鑸囩郴绲�(t菕ng)鍒嗛洟
B椤炵郴绲�(t菕ng)鈹€鈹€瑭查绯荤当(t菕ng)鍍呭寘鎷柈鐩告帴鍦版晠闅滅煭鏅傞亱琛岀殑姊濅欢锛屾帴鍦版晠闅滄檪闁撴噳(y墨ng)涓嶈秴閬�1h, 浣嗗湪浠讳綍鎯呮硜涓�锛屾渶闀蜂笉瓒呴亷8h姣忓勾鎺ュ湴鏁呴殰绺芥寔绾�(x霉)鏅傞枔涓嶈秴閬�125h锛�
C椤炵郴绲�(t菕ng)鈹€鈹€涓嶅爆浜嶢椤�銆丅椤炵殑绯荤当(t菕ng)銆�
System category A鈹€鈹€This category comprises those systems in which any phase conductor that comes in contact with earth or an earth conductor. is disconnected from the system within 1 min.
System category B 鈹€鈹€This category comprises those system which,under faultconditions,are operated,are operated for ashorttimewith one phase earthed.This period should not exceed 1 h..Fora longer period, not exceeding 8h on any occasion, can be tolerated.The total duration of earth faults in any year should not exceed 125h.
System categeory C鈹€鈹€This category comprises all systems which do not fall into A and B
闆荤簻鐨勫瀷铏烼ype of cable
鍨嬭櫉 Type 鍚嶇ū Designation 閬╃敤鑼冨湇 Application
YJV 閵呰姱浜よ伅(li谩n)鑱氫箼鐑禃绶f隘涔欑儻璀峰闆诲姏闆荤簻 Copper conductor,XLPE insulated and PVC sheathed power cable 瀹ゅ収(n猫i)銆侀毀閬撳強闆荤簻婧濈瓑鍫存墍锛屼笉鑳芥壙鍙楁姊板鍔�銆傚柈鑺浕绾滀笉鍏佽ū鏁疯ō(sh猫)鍦ㄧ鎬х閬撲腑銆� For laying indoors 銆� intunnel or cable trench,unable to bear external mechan-icalforces.Single-core cable in magnetic duct is not permissible
YJLY 閶佽姱浜よ伅(li谩n)鑱氫箼鐑禃绶d箼鐑濂楅浕鍔涢浕绾� Aluminium conductor, XLPE insulated and PVC sheathed power cable
YJY 閵呰姱浜よ伅(li谩n)鑱氫箼鐑禃绶f隘涔欑儻璀峰闆诲姏闆荤簻 Copper conductor ,XLPE insulated and PEsheathed power cable
YJLY 閶佽姱浜よ伅(li谩n)鑱氫箼鐑禃绶f隘涔欑儻璀峰闆诲姏闆荤簻 Alumimium conductor ,XLPE insulated and PEsheathed power cable
YJV22 閵呰姱浜よ伅(li谩n)鑱氫箼鐑禃绶i嫾甯堕帶瑁濊仛姘箼鐑濂楅浕鍔涢浕绾� Copper conductor ,XLPE insulated, steel tape armoured and PVC sheathed power cable 瀹ゅ収(n猫i)銆侀毀閬�銆侀浕绾滄簼鍏�(n猫i)锛屾垨鍩嬪湴鏁疯ō(sh猫)绛夛紝鑳芥壙鍙椾竴瀹氭姊板鍔�锛屼絾涓嶈兘鎵垮彈澶х殑鎷夊姏銆� For laying indoors 銆� in tunnel, cable trench, or direct in ground,able to bear external mechanicalforces, but unable to bear large pulling force 銆�
YJLV22 閶佽姱浜よ伅(li谩n)鑱氫箼鐑禃绶i嫾甯堕帶瑁濊仛姘箼鐑濂楅浕鍔涢浕绾� Aluminium conductor ,XLPE insulated ,steel tape armoured and PVC sheathed power cable
YJV23 閵呰姱浜よ伅(li谩n)鑱氫箼鐑禃绶i嫾甯堕帶瑁濊仛姘箼鐑濂楅浕鍔涢浕绾� Copper conductor ,XLPE insulated ,steel tape armoured and PVC sheathed power cable
YJLV23 閶佽姱浜よ伅(li谩n)鑱氫箼鐑禃绶i嫾甯堕帶瑁濊仛姘箼鐑濂楅浕鍔涢浕绾� Aluminium conductor ,XLPE insulated ,steel tape armoured and PVC sheathed power cable
YJV32 閵呰姱浜よ伅(li谩n)鑱氫箼鐑禃绶g窗閶肩挡閹ц鑱氭隘涔欑儻璀峰闆诲姏闆荤簻 Copper conductor,XLPE insulated,steel wire armoured and PVC sheathed power cable 瀹ゅ収(n猫i)銆侀毀閬撱€侀浕绾滄簼銆佽睅浜曟垨鍩嬪湴鏁疯ō(sh猫)绛�锛岃兘鎵垮彈姗熸澶栧姏鍜屼竴瀹氱殑鎷夊姏銆� For laying indoors 銆� in tunnel, cable french, well or direct in ground,able to bear external mechanical forces, and certain force 銆�
YJLV32 閶佽姱浜よ伅(li谩n)鑱氫箼鐑禃绶g窗閶肩挡閹ц鑱氭隘涔欑儻璀峰闆诲姏闆荤簻 Aluminium conductor ,XLPE insulated, steel wire armoured and PVC sheathed power cable
YJV33 閵呰姱浜よ伅(li谩n)鑱氫箼鐑禃绶g窗閶肩挡閹ц鑱氭隘涔欑儻璀峰闆诲姏闆荤簻 Copper conductor ,XLPE insulated ,steel wire armoured and PVC sheathed power cable
YJLV33 閶佽姱浜よ伅(li谩n)鑱氫箼鐑禃绶i嫾甯堕帶瑁濊仛姘箼鐑濂楅浕鍔涢浕绾� Aluminium conductor ,XLPE insulated ,steel wire armoured and PVC sheathed power cable
鐢熺敘(ch菐n)鑼冨湇Production range of cable
鍨嬭櫉 Type 鑺暩(sh霉) Nomber of cores 椤嶅畾闆诲 Rated Voltage kV
3.6/6 6/6 6/10 8.7/10 8.7/15 12/20 18/20 18/30 21/35 26/35
灏�(d菐o)楂旀绋辨埅闈� Nominal cross-section of conductlr mm2
YJV
YJLV
YJY
YJLY
1 25-800 25-800 25-800 35-800 50-630 50-630 50-630
3 25-630 25-630 25-500 35-500 50-400 50-400 50-400
YJV22
YJLV22
YJY23
YJLY23
1 25-800 25-800 25-800 35-800 50-630 50-630 50-630
3 25-630 25-630 25-500 35-500 50-400 50-400 50-400
YJV32
YJLV32
YJY33
YJLY33
1 25-800 25-800 25-800 35-800 50-630 50-630 50-630
3 25-630 25-630 25-400 35-400 50-240 50-185 50-150
瑭崇窗鎯呮硜璜嬬櫥閷�www.dxdlxszx.com
鐗堟瑠(qu谩n)鑱叉槑锛氬伐鎺х恫(w菐ng)杞�(zhu菐n)杓変綔鍝佸潎娉ㄦ槑鍑鸿檿锛屾湰缍�(w菐ng)鏈敞鏄庡嚭铏曞拰杞�(zhu菐n)杓夌殑锛屾槸鍑轰簬鍌抽仦鏇村淇℃伅涔嬬洰鐨�锛屽苟涓嶆剰鍛� 钁楄磰鍚屽叾瑙€榛炴垨璀夊鍏跺収(n猫i)瀹圭殑鐪熷鎬�銆傚杞�(zhu菐n)杓変綔鍝佷镜鐘綔鑰呯讲鍚嶆瑠(qu谩n)锛屾垨鏈夊叾浠栬濡傜増娆�(qu谩n)銆佽倴鍍忔瑠(qu谩n)銆佺煡璀樼敘(ch菐n)娆�(qu谩n)绛夋柟闈㈢殑鍌峰锛屽苟闈炴湰缍�(w菐ng)鏁呮剰鐐轰箣锛屽湪鎺ュ埌鐩搁棞(gu膩n)娆�(qu谩n)鍒╀汉閫氱煡鍚庡皣绔嬪嵆鍔犱互鏇存銆傝伅(li谩n)绯婚浕瑭憋細0571锛�87774297銆�